Danfoss Electronics Coils for solenoid valves Data sheet

MAKING MODERN LIVING POSSIBLE
Data sheet
Coils for solenoid valves
The coils are specially designed to operate in the aggressive environment of high humidity and temperature uctuations that you nd in most refrigeration systems.
Features Encapsulated coils with long operating
life, even under extreme conditions.
• Standard coils for a.c. or d.c.
• Standard coils available with 3-core
cable, terminal box or DIN plugs.
• Standard coils from 12 V to 420 V, 50,
60 or 50/60 Hz.
The Clip-on coils are available for the entire range of Danfoss solenoid valves for refrigeration, freezing and air conditioning purposes.
• Standard coils dimensioned for max.
opening dierential pressure (MOPD) of up to 21 bar.
• Coils can be tted without the use of
tools.
© Danfoss A/S (AC-MCI sw) 2013-12 DKRCC.PD.BS0.F1.02 / 520H8348 1
Data sheet Coils for solenoid valves
Technical data
Connection
Ambient temperature
10 or 12 W a.c. coil for NC (normally closed) valve:
-40 +80 °C ­10 W a.c. coil for NO (normally open) valve:
-40 +55 °C 20 W coil for NC and NO valve:
-40 +50 °C
Permissible voltage variation
10 , 12 and 20 W a.c. coils: +10 -15 % Double frequency coils and 20 W d.c. coils: ±10 %.
3-core cable
The external thread in the screwed cable entry suits exible steel hose or corresponding cable protection.
Terminal box
Leads are connected to terminal screws in the terminal box. The box is tted with a Pg 13.5 screwed entry for 6 14 mm cable. Max. lead cross section: 2.5 mm2.
Enclosure
IP 67 with cable or terminal box IP 20 with DIN plugs and protective cap IP 65 with DIN socket IP 00 with DIN plugs.
Approvals
See under the required solenoid valve.
DIN plugs
The three pins on the coil can be tted with spade tabs, 6.3 mm wide (to DIN 46247). The two current carrying pins can also be tted with spade tabs, 4.8 mm wide. Max. lead cross section: 1.5 mm2. Use of the protective cap supplied will prevent inadvertent contact with live parts.
DIN socket
(to DIN 43650) Leads are connected in the socket. The socket is tted with a Pg 11 screwed entry for 6 12 mm.
2 DKRCC.PD.BS0.F1.02 / 520H8348 © Danfoss A/S (AC-MCI sw) 2013-12
Data sheet Coils for solenoid valves
Ordering
Clip-on coils
Valve type
VoltageVFrequency
Hz
Alternating current a.c.
12 50 - 018F6706 - -
24 50 018F6257 018F6707 018F6182 018F7358
42 50 - 018F6708 - -
48 50 - 018F6709 - -
EVR 2 40 (NC) EVR 6 22 (NO) EVRH 4 40 EVRC EVRA EVR AT EVRS / EVRST EVM (NC)
115 50 - 018F6711 - 018F7361
220-230 50 018F6251 018F6701 018F6176 018F7351
240 50 018F6252 018F6702 018F6177 018F7352
380-400 50 018F6253 018F6703 - -
420 50 - 018F6704 018F6179 -
24 60 018F6265 018F6715 - -
115 60 018F6260 018F6710 018F6185 -
220 60 018F6264 018F6714 018F6189 -
240 60 - 018F6713 - -
110 50/60 018F6280 018F6730 018F6192 018F7360
220-230 50/60 018F6282 018F6732 018F6193 018F7363
*) Can only be used with DIN socket
Valve type
VoltageVFrequencyHzCode no.
1 m
3-core cable
IP 67
Terminal box
Code no.
Terminal box
IP 67
Power
consumption
DIN plugs and
protect. cap
IP 20
DIN plugs *)
Power con-
sumption
Holding:
10 W
21 VA
Inrush:
44 VA
Alternating current a.c.
24 50 018F6807
48 50 018F6809
EVR 3 40 EVRC EVRA EVR AT EVRS / EVRST EVM (NC / NO)
110 50 018F6811
220-230 50 018F6801
240 50 018F6802
380-400 50 018F6803
24 60 018F6815
110 60 018F6813
220 60 018F6814
Holding:
12 W
26 VA
Inrush:
55 VA
Alternating current a.c.
EVR 2 40 (NC) EVR 6 22 (NO) EVRH 4 40 (NO) EVRC/EVRA/ EVRAT/EVRST/ EVM (NC)
24 50 018F6901
24 50 018F6905
230 60 018F6902
Holding:
20 W 45VA
Inrush:
65VA
Recommended use for EVRH with high MOPD (38 bar)
See "Opening dierential pressure" under "Technical data" for the valve concerned.
When replacing a coil with terminal box, it is sucent to change the coil unit itself. Therefore, order coil with DIN plugs and protective cap.
© Danfoss A/S (AC-MCI sw) 2013-12 DKRCC.PD.BS0.F1.02 / 520H8348 3
71
Danf M18F02
94
M18F03
86
Dan M18F04
51
28
110
M18F05
Data sheet Coils for solenoid valves
Ordering (Continued)
Valve type
Voltage
V
Code no.
Terminal box
IP 67
Power
consumption
Direct current d.c. Coil type I
EVR 2 − 15 (NC) EVR 25 − 40 (NC/NO) EVR 6 − 15 (NO) EVRC 10 − 15 EVRA 3 − 15 (NC) EVRA 25 − 40 (NC) EVRAT 10 − 15 (NC) EVRS / EVRST 3 − 15 EVM (NC/NO)
12 018F6856
24 018F6857
48 018F6859
110 018F6860
115 018F6861
220 018F6851
20 W
Direct current d.c. Coil type II
EVR 20 − 22 (NC/NO) EVRC 20 EVRA 20 EVRAT 20 EVRST 20
12 018F6886
24 018F6887
48 018F6889
110 018F6890
220 018F6881
20 W
See "Opening dierential pressure" under "Technical data" for the valve concerned.
When replacing a coil with terminal box, it is sucent to change the coil unit itself. Therefore, order coil with DIN plugs and protective cap.
Accessories
Description Code no.
DIN socket 042N0156
Terminal box with build-in light emmiting indicator diode for solenoid valves 018Z0089
Dimension and weight
Dimensions and weights
See under the required solenoid valve.
57
45
47
Danfoss
Terminal box 10 - 12 W
Weight 0.29 Kg / 0.6 lbs
57
45
oss
Cable 10 - 12 W
Weight 0.29 Kg / 0.6 lbs
57
45
46
57
45
foss
DIN socket 10 - 12 W
Weight 0.24 Kg / 0.5 lbs
47
Danfoss
Terminal box 20 W
Weight 0.55 Kg / 1.2 lbs
68
4 DKRCC.PD.BS0.F1.02 / 520H8348 © Danfoss A/S (AC-MCI sw) 2013-12
Loading...