Danfoss Electronics Coils for solenoid valves Data sheet

MAKING MODERN LIVING POSSIBLE
Data sheet
Coils for solenoid valves
The coils are specially designed to operate in the aggressive environment of high humidity and temperature uctuations that you nd in most refrigeration systems.
Features Encapsulated coils with long operating
life, even under extreme conditions.
• Standard coils for a.c. or d.c.
• Standard coils available with 3-core
cable, terminal box or DIN plugs.
• Standard coils from 12 V to 420 V, 50,
60 or 50/60 Hz.
The Clip-on coils are available for the entire range of Danfoss solenoid valves for refrigeration, freezing and air conditioning purposes.
• Standard coils dimensioned for max.
opening dierential pressure (MOPD) of up to 21 bar.
• Coils can be tted without the use of
tools.
© Danfoss A/S (AC-MCI sw) 2013-12 DKRCC.PD.BS0.F1.02 / 520H8348 1
Data sheet Coils for solenoid valves
Technical data
Connection
Ambient temperature
10 or 12 W a.c. coil for NC (normally closed) valve:
-40 +80 °C ­10 W a.c. coil for NO (normally open) valve:
-40 +55 °C 20 W coil for NC and NO valve:
-40 +50 °C
Permissible voltage variation
10 , 12 and 20 W a.c. coils: +10 -15 % Double frequency coils and 20 W d.c. coils: ±10 %.
3-core cable
The external thread in the screwed cable entry suits exible steel hose or corresponding cable protection.
Terminal box
Leads are connected to terminal screws in the terminal box. The box is tted with a Pg 13.5 screwed entry for 6 14 mm cable. Max. lead cross section: 2.5 mm2.
Enclosure
IP 67 with cable or terminal box IP 20 with DIN plugs and protective cap IP 65 with DIN socket IP 00 with DIN plugs.
Approvals
See under the required solenoid valve.
DIN plugs
The three pins on the coil can be tted with spade tabs, 6.3 mm wide (to DIN 46247). The two current carrying pins can also be tted with spade tabs, 4.8 mm wide. Max. lead cross section: 1.5 mm2. Use of the protective cap supplied will prevent inadvertent contact with live parts.
DIN socket
(to DIN 43650) Leads are connected in the socket. The socket is tted with a Pg 11 screwed entry for 6 12 mm.
2 DKRCC.PD.BS0.F1.02 / 520H8348 © Danfoss A/S (AC-MCI sw) 2013-12