Danfoss Electronics BD80F Data Sheet

Datasheets
BD80F
Direct Current Compressor
R134a 12/24V DC
General
Code number (without electronic units) 101Z0280
Electronic unit - High Speed 101N0390, 28 pcs: 101N0391
Compressors on pallet 150
Application
Application LBP
Evaporating temperature °C -30 to -5
Voltage/max. voltage VDC 9.6 - 17 / 21.3 - 31.5
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Application LBP MBP HBP
32°C S
38°C S
43°C S – Remarks on application:
Motor
Motor type variable speed
Resistance, all 3 windings (25°C) Ω 1.8
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 300
Free gas volume in compressor cm
Weight - Compressor/Electronic unit kg 4.4/0.32
°C 60 (70)
3
3
3
3.00
150 (polyolester)
870
S = Static cooling normally suffi cient O = Oil cooling
= Fan cooling 1.5 m/s
F
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally suffi cent = not applicable in this area
Standard battery protection settings
Voltage 12V 24V
Cut out VDC 10.4 22.8
Cut in VDC 11.7 24.2
Dimensions
Height mm A 137
Suction connector location/I.D. mm | angle C 6.2 | 40°
Process connector location/I.D. mm | angle D 6.2 | 45°
Discharge connector location/I.D. mm | angle E 5.0 | 21°
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
(refer to electronic unit Instructions for optional settings)
B 135
B1 128
B2 73
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
© Danfoss | DCS (CC) | 2016.11
DEHC.ED.100.G7.02 | 1
Capacity (EN 12900 Household/CECOMAF) 24V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,500 35.2 49.8 55.3 67.0 87.3 112 140 3,100 41.9 59.2 65.8 79.8 104 133 168 3,800 50.1 70.8 78.7 95.4 125 159 200 4,400 54.9 78.1 86.8 105 138 176 221
Capacity (ASHRAE LBP) 24V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,500 43.7 61.8 68.6 83.1 108 138 174 3,100 52.0 73.4 81.6 98.8 129 165 208 3,800 62.1 87.8 97.5 118 154 197 248 4,400 68.1 96.7 108 130 171 218 274
Power consumption 24V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,500 38.4 47.9 51.2 57.8 68.2 79.5 91.9 3,100 46.9 58.9 62.9 70.8 83.4 97.3 113 3,800 57.5 72.0 76.9 86.5 102 119 139 4,400 66.3 83.5 89.2 100 118 138 161
Current consumption
(for 12V applications the following must be doubled) A
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,500 1.6 2.0 2.1 2.4 2.8 3.3 3.8 3,100 1.9 2.4 2.6 3.0 3.5 4.1 4.7 3,800 2.4 3.0 3.2 3.6 4.3 5.0 5.8 4,400 2.8 3.5 3.7 4.2 4.9 5.8 6.7
COP (EN 12900 Household/CECOMAF) 24V DC, static cooling W/W
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,500 0.92 1.04 1.08 1.16 1.28 1.40 1.53 3,100 0.89 1.01 1.05 1.13 1.25 1.37 1.48 3,800 0.87 0.98 1.02 1.10 1.22 1.34 1.44 4,400 0.83 0.94 0.97 1.05 1.16 1.27 1.37
COP (ASHRAE LBP) 24V DC, static cooling W/W
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 2,500 1.14 1.29 1.34 1.44 1.59 1.75 1.90 3,100 1.10 1.25 1.30 1.40 1.55 1.70 1.85 3,800 1.07 1.22 1.27 1.37 1.52 1.66 1.80 4,400 1.02 1.16 1.21 1.30 1.45 1.58 1.71
Test conditions EN 12900/CECOMAF ASHRAE LBP
Condensing temperature 55°C 54.4°C Ambient temperature 32°C 32°C Suction gas temperature 32°C 32°C Liquid temperature no subcooling 32°C
Accessories for BD80F Code number
Bolt joint for one comp. Ø:16 mm 118-1917 Bolt joint in quantities Ø:16 mm 118-1918 Snap-on in quantities Ø:16 mm 118-1919 Remote kit (without cable) 105N9210 One Wire/LIN gateway 105N9501 Automobile fuse, DIN 7258 12V: 30A | 24V: 15 A Main switch
min. 30A
Not deliverable
from Secop
Compressor speed
Electronit unit
Code number
Resistor (R1) [Ω] Motor speed
calculated
values [rpm]
0 AEO
101N0390
with AEO
203 2,500
451 3,100
867 3,800
1700 4,400
In AEO (Adaptive Energy Optimizing) speed mode the BD com­ressor will always adapt its speed to the actual cooling demand.
Wire dimensions
Size Max. length* Max. length*
Cross AWG 12V operation 24V operation
section
2
[mm
] [Gauge] [m] [ft.] [m] [ft.]
6 10 2.5 8 5 16
*Length between battery and electronic unit
Operational errors
Error code
or LED
fl ashes
6
Thermostat failure
(If the NTC thermistor is short-circuit or has no connection).
Thermal cut-out of electronic unit
5
(If the refrigeration system has been too hea vi ly loaded, or if the ambient tem pe ra ture is high, the electronic unit will run too hot).
Minimum motor speed error
4
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,850 rpm).
Motor start error
3
(The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)).
Too many start attempts or fan over current
2
(Too many compressor or fan starts in short time or fan current higher than 0.5A
1
Battery protection cut-out
(The voltage is outside the cut-out setting).
Error type
Can be read out in the software
TOOL4COOL®
).
avg
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.