Barcode on white backgroun
Datasheets
BD35F
Direct Current Compressor
R134a 12/24V DC, 10-45V DC Solar
& 100-240V AC 50/60Hz
General
Code number (without electronic units) 101Z0200 Approvals
Electronic unit 12/24V DC - Standard 101N0212, 30 pcs: 101N0213 –
Electronic unit 12/24V DC - AEO 101N0340, 30 pcs: 101N0341 UL
Electronic unit 10-45V DC - Solar 101N0420, 30 pcs: 101N0421 –
Electronic unit 12/24V DC & 100-240V AC 50/60Hz 101N0510, 28 pcs: 101N0511 UL / VDE
Electronic unit 12/24V DC - Automotive 101N0650, 30 pcs: 101N0651 UL
Compressors on pallet 150
Application
Application LBP/MBP/HBP
Evaporating temperature °C -30 to 0 (10)
Voltage range DC VDC 9.6 - 17 / 21.3 - 31.5
Voltage range AC V/Hz 100 - 240 / 50/60
Voltage range for solar applications VDC 10 - 45
Max. condensing temperature continuous (short)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Application LBP MBP HBP
32°C S S S
38°C S S S
43°C S S S
Remarks on application: Fan cooling F
Motor
Motor type variable speed
Resistance, all 3 windings (25°C) Ω 2.2
depending on application and speed.
1
°C 60 (70)
Blue stripe
Grey background
Country of origin or manufacturer
BD35F
only with BD controller
R134a
S =Staticcoolingnormallysufcient
O = Oil cooling
= Fan cooling 1.5 m/s
F
1
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
serial number
d
Made by Secop
101Z
0200
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 300
Free gas volume in compressor cm
Weight - Compressor/Electronic unit kg 4.3 / 0.19 (Standard)
Standard battery protection settings
Voltage 12V 24V
Cut out VDC 10.4 22.8
Cut in VDC 11.7 24.2
Dimensions
Height mm A 137
Suction connector location/I.D. mm | angle C 6.2 | 40°
Process connector location/I.D. mm | angle D 6.2 | 45°
Discharge connector location/I.D. mm | angle E 5.0 | 21°
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
© Danfoss | DCS (CC) | 2016.11
3
3
3
(refer to electronic unit Instructions for optional settings)
B 135
B1 128
B2 73
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
material | comment Cu-plated steel | Al cap
2.00
150 (polyolester)
870
DEHC.ED.100.G9.02 | 1
Capacity (EN 12900 Household/CECOMAF) 12V DC, static cooling watt
Interface connected to
(T
non interface option (resistors)
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
All trademarks in this material are property of the respec
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,000 16.0 23.8 26.7 32.9 43.7 56.5 71.8 89.8 111 121 136
2,500 18.8 29.9 33.9 41.9 55.4 71.1 89.8 11 2 139 152
3,000 22.4 32.9 37.1 46.1 62.5 82.2 106 133
3,500 27.0 35.9 40.2 50.3 69.8 93.9 122
Capacity (ASHRAE LBP) 12V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,000 20.0 29.8 33.4 41.2 54.6 70.6 89.7 112 139 152 169
2,500 23.6 37.5 42.4 52.4 69.2 88.8 112 140 173 190
3,000 28.1 41.3 46.5 57.9 78.2 103 132 166
3,500 33.9 45.1 50.5 63.1 87.3 11 7 153
Power consumption 12V DC, static cooling watt
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,000 17.7 22.9 24.6 27.7 32.2 36.7 41.3 46.2 51.6 54.3 57.8
2,500 22.1 29.7 32.0 36.3 42.4 48.1 53.8 59.7 66.1 69.1
3,000 29.3 34.6 36.7 41.2 48.7 56.5 64.5 72.0
3,500 34.5 41.3 43.8 48.9 57.3 66.2 75.4
Current consumption (for 24V applications the following must be halfed) A
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,000 1.4 1.9 2.0 2.3 2.7 3.1 3.4 3.8 4.3 4.5 4.8
2,500 1.8 2.5 2.7 3.0 3.5 4.0 4.5 5.0 5.5 5.8
3,000 2.4 2.9 3.1 3.4 4.0 4.7 5.3 6.0
3,500 2.9 3.4 3.6 4.1 4.8 5.5 6.3
COP (EN 12900 Household/CECOMAF) 12V DC, static cooling W/W
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,000 0.90 1.04 1.09 1.19 1.36 1.54 1.74 1.94 2.15 2.24 2.35
2,500 0.85 1.01 1.06 1.15 1.31 1.48 1.67 1.88 2.10 2.20
3,000 0.76 0.95 1.01 1.12 1.28 1.45 1.64 1.85
3,500 0.78 0.87 0.92 1.03 1.22 1.42 1.62
COP (ASHRAE LBP) 12V DC, static cooling W/W
rpm \ °C -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,000 1.13 1.30 1.36 1.49 1.70 1.93 2.18 2.44 2.70 2.81 2.95
2,500 1.07 1.26 1.33 1.45 1.64 1.86 2.10 2.36 2.64 2.77
3,000 0.96 1.19 1.27 1.41 1.61 1.83 2.06 2.32
3,500 0.98 1.09 1.15 1.29 1.53 1.78 2.03
Test conditions with electronic units EN 12900/CECOMAF ASHRAE LBP
Condensing temperature
55°C 54.4°C
Ambient temperature 32°C 32°C
Suction gas temperature 32°C 32°C
Liquid temperature no subcooling 32°C
101N0212
101N0650
Accessories for BD35F Code number
Bolt joint for one comp. Ø:16 mm 118-1917
Bolt joint in quantities Ø:16 mm 118-1918
Snap-on in quantities Ø:16 mm 118-1919
Remote kit (without cable) 105N9210
One Wire/LIN gateway 105N9501
DC usage:
AC usage:
Automoblie fuse, DIN 7258 12V: 15A | 24V: 7.5 A
Main switch
min. 20A
Fuse, 100-240V
Main switch
Power supply
option a
OOL4COOL® or display)
One Wire LIN Gateway
Secop One Wire
Tx Rx
LIN Gateway
USB
Code no.: 105N9501
USB
USB 2.0
105N9501– V01.00
D/I C
NTC resistor
–t°
option 2
Fuse
One Wire
/ LIN
Electronics
(One Wire / LIN)
and
mech. Thermostat
option 1
Main switch
+
Fan
-
LED
+
-
option b
LED connected
to and+ D/I
R1
Power supply
One Wire LIN Gateway
USB
option a
Interface connected to and
(TOOL4COOL® or display)
NTC resistor
–t°
101N0340
101N0650
R2
R1 = speed selection
R2 = battery protection
non interface option (resistors)
Fuse
Secop One Wire
Tx Rx
LIN Gateway
One Wire
Code no.: 105N9501
/ LIN
USB
Electronics
USB 2.0
(One Wire / LIN)
105N9501–V01.00
D/I C
mech. Thermostat
min. 6A
+
+
F
D/I
C
P
T
Main switch
LED
+
-
option b
LED connected
to and+ D/I
~
100-240V AC
R1
Terminal plug
Main switch
50/60Hz
R2
Not
deliverable
from Secop
101N0510
L
N
–
+
+
Fan
-
F
A
C
D/I
C
P
T
compressor baseplate
R1 = speed selection
R2 = battery protection
Compressor speed
Electronit unit Resistor (R1)
[Ω]
Code number
calculated
Motor speed
values [rpm]
0 2,000 5
101N0212
101N0510
101N0650
277 2,500 4
692 3,000 3
1523 3,500 2
0 AEO 6
101N0340
101N0420
with AEO
173 2,000 5
450 2,500 4
865 3,000 3
1696 3,500 2
In AEO (Adaptive Energy Optimizing) speed mode the BD comressor will always adapt its speed to the actual cooling demand.
Wire dimensions DC
Size Max. length* Max. length*
Cross AWG 12V operation 24V operation
section
2
] [Gauge] [m] [ft.] [m] [ft.]
[mm
2.5 12 2.5 8 5 16
4 12 4 13 8 26
6 10 6 20 12 39
10 8 10 33 20 66
*Length between battery and electronic unit
Wire dimensions AC
Cross section min. 0.75 mm
Operational errors
Error
code
or LED
ashes
Thermostat failure
6
2
or AWG 18
Error type
Can be read out in the software
TOOL4COOL®
(If the NTC thermistor is short-circuit or has no connection).
Thermal cut-out of electronic unit
5
(If the refrigeration system has been too hea vi ly loaded, or if the
ambient tem pe ra ture is high, the electronic unit will run too hot).
Minimum motor speed error
4
(If the refrigeration system is too heavily loaded, the motor
cannot maintain minimum speed at approximately 1,850 rpm).
Motor start error
3
(The rotor is blocked or the differential pressure in the
refrigeration system is too high (>5 bar)).
Too many start attempts or fan over current
2
(Too many compressor or fan starts in short time or fan
current higher than 0.5A
Battery protection cut-out
1
).
avg
(The voltage is outside the cut-out setting).
R1 = speed selection
R2 = battery protection
non interface option (resistors)
8615-18
101N0420
+
+
F
D/I
C
P
T
Solar panel
One Wire LIN Gateway
Secop One Wire
Tx Rx
LIN Gateway
USB
Code no.: 105N9501
USB
Electronics
USB 2.0
(One Wire / LIN)
105N9501– V01.00
option a
Interface connected to and
(TOOL4COOL® or display)
D/I C
NTC resistor
–t°
option 2
Remote kit
Fuse
+
Fan
-
One Wire
/ LIN
option b
LED connected
to and+ D/I
mech. Thermostat
option 1
+
-
Main switch
LED
R1
Control
circuit
current[mA]