Danfoss Electronics ACB, CCB Data Sheet

Data sheet
Cartridge pressure switch Type ACB and CCB
Pressure controls ACB and CCB are compact disc type pressure switches with xed set-points for long-standing use in refrigeration and air conditioning systems. They provide automatic or manual reset limit protection.
The small size, lightness and high degree of protection means that it can be mounted directly on the refrigeration systems.
The cartridge switch is available with dierent pressure settings and pressure connections to suit customer requirements.
All these features reduce installation costs and save space.
Features
Approvals
y Wide range
y Fixed pressure set points
y Normally Closed, Normally Open or SPDT
contact system
y Automatic or manual reset
y Various port ttings for soldering or direct
mounting
y Spades or cables
y CE according to EN 12263
y Technical Inspection Association TÜV
TUV certicate no. 01 202 931/Q-04 0018 and 01 202 971/B-17-0002
y Low Voltage Directive 2014/35/EU
y Stripped ends or customer specic electrical
plug
y Open or water-proof (IP65) version
y Type ACB for use as high and low pressure cut
in and cut out as well as fan cycling
y Type CCB available for CO2 refrigerants
y Compact design and easy to install
y UL recognized (type ACB only):
- UL 873 and CSA C22.2 No. 24-93
- UL 121201 and CSA C22/2 No.213-17 (for ammable refrigerants only)
© Danfoss | DCS (rm) | 2019.02 DKRCC.PD.CH0.B8.02 | 520H11785 | 1
Data sheet | Cartridge pressure switch, type CB
High
Pressure
Low
Pressure
Fan Control
Compressor
Condenser
Evaporator
Expansion valve
Air conditioning and Refrigeration
Applications Low Pressure safety pressure switch
Condenser fan switch
Compressor stop – start
High Pressure safety pressure switch
Pump-down switch
2 | 520H11785 | DKRCC.PD.CH0.B8.02
© Danfoss | DCS (rm) | 2019.02
Data sheet | Cartridge pressure switch, type CB
Technical data
Typ e
ACB CCB
Water-proof (W) Open – spade connector (O) Water-proof (W)
R22, R134a, R404A, R407C, R407F, R410A, R438A,
R448A, R449A, R452A, R513A
For flammable refrigerants please contact your
Medium
For complete list of approved refrigerants, visit www.
nearest Danfoss office.
R74 4 (CO2)
products.danfoss.com and search for individual code
numbers, where refrigerants are listed as part of
technical data
Range
-0.5 – 45 bar
-7 – 652 psi
100 – 150 bar 1450 –2176 psi
Reset Automatic, Manual Automatic
Contact function SPST-NO, SPST-NC, SPDT SPS T-NC
Electrical connections AWG18 cables Spades (size 6.35mm x 0.8 mm) AWG18 cables
Cable length 150 cm (black) 150 cm (black)
6 A @ 250 V AC for SPST
Contact load
4 A @ 250 V AC for SPDT
0,01 - 0,05 A @ 12/24 V DC
1
4 in ODM solder
Pressure connections
1
4 in SAE female flare
6.35 mm solder
with depressure pin
6 mm ODM solder
Maximum working pressure PS / MWP
Burst pressure
Media temperature
45 bar
650 psi
140 bar
2030 psi
-55 – 135 °C
-67 – 275 °F
165 bar
2393 psi
375 bar
5440 psi
-30 – 100 °C
-20 – 210 °F
Ambient temperature -30 – 85 °C
Enclosure IP65 No electrical protection IP65
Customer specic features are available in a wide selection. Please refer to Specication Build-up on page 8.
© Danfoss | DCS (rm) | 2019.02 DKRCC.PD.CH0.B8.02 | 520H11785 | 3
Data sheet | Cartridge pressure switch, type CB
p
C
HL
p
C
HL
p
C
L
p
C
p
C
HH
p
C
L
p
C
p
C
HH
Load (A)
01
Cycles
Lifetime
Switch type:
SPST auto reset, Normally open Pressure setting : max 3 MPa
5
4
3
2
1
0
0500000 100000
As general rule, ACB pressure switches are capable to cover applications requiring cycling from 100000 to 1500000 cycles dependent on current load. The exact number of cycles in any of given application is to be determined by appropriate testing. Danfoss-Saginomiya reserves the right to change or modify specications at any time without prior notice.
Danfoss
60N9020
500000
Electrical connections
SPST auto reset, Normally close – up to 100000 cycles SPST manual reset, Normally close – 10000 cycles SPDT auto reset – up to 100000 cycles SPDT manual reset – 10000 cycles
SPST - Single Pole Single Throw SPDT - Single Pole Double Throw
(NO) - Normally Open (NC) - Normally Closed
SPDT SPDT with manual
reset
4 | 520H11785 | DKRCC.PD.CH0.B8.02
SPST NO SPST NC
SPST with manual reset
© Danfoss | DCS (rm) | 2019.02
Danfoss
61F8024.10
Data sheet | Cartridge pressure switch, type CB
Standard models
Type ACB
Application Reset
Auto.
Auto.
Man.
Auto.
Man. SPST-NC / W
Auto. SPDT / W
Auto.
Man.
High pressure cut out
Auto. SPST-NC / O
Auto. SPDT / W
Man. SPDT / W
Auto.
Auto.
Man.
Auto. SPDT / W
Cut out Cut in
[bar]
[psi]
18 ± 0.7
260 ± 10
20 ± 1
290 ± 14
23 ± 0.7
335 ± 10
26 ± 1
380 ± 15
28 ± 1
405 ± 14
31 ± 1
405 ± 14
42 ± 1.2
610 ± 17
[bar]
[psi]
13 ± 1.2
190 ± 17
16 ± 1.5
230 ± 21
19 ± 1.2
275 ± 17
20 ± 1.5
290 ± 22
21 ± 1.5
305 ± 22
24 ± 1.5
350 ± 22
33 ± 2
480 ± 29
Contact system
/ enclosure type
W-water-proof
Connection type
Solder Flare
types with
cable (IP65)
O-open (spade
connector)
6 mm
types / no cable
(IP00)
SPST-NC / W
061F7504
ACB-2UB50 4W
ACB-2UB505W
SPDT / W
SPST-NC / O
SPST-NC / W
SPST-NC / O
SPDT / W
SPST-NC / W
061F7507
ACB-2UB507W
ACB-2UB508W
SPST-NC / O
061F9703
ACB-2UB803MW
ACB-2UB814MW
061F7510
SPST-NC / W
SPST-NC / W
ACB-2UB510W
061F8493
ACB-2UB 464W
ACB-2UB513W
SPST-NC / O
SPDT / W
061F7515
SPST-NC / W
ACB-2UB515W
ACB-2UB516W
1
4 in
061F750 5
061F8710
ACB -2UB210
061F8707
ACB-2UB207
061F750 8
061F8705
ACB-2UB205
061F 9714
061F 7513
061F8704
ACB-2UB20 4
061F8706
ACB-2UB20 6
061F7516
7/16-20 UNF
with
depressure pin
061F7506
ACB-2UB50 6W
061F9057
ACB-2UC 59W
061F870 8
ACB-2UB20 8
061F8494
ACB-2UB465W
061F8703
ACB-2UB203
061F9056
ACB-2UC58W
061F9243
ACB-2UC63MW
061F750 9
ACB-2UB50 9W
061F8701
ACB-2UB201
061F 9713
ACB-2UB813MW
061F9055
ACB-2UC 57W
061F 7514
ACB -2UB514W
061F952 2
ACB-2UB327MW
061F870 0
ACB-2UB20 0
061F9054
ACB-2UC56W
061F9242
ACB-2UC62MW
061F8492
ACB-2UB463W
061F8702
ACB-2UB202
061F9053
ACB-2UC 55W
061F7517
AC B -2UB 517W
061F9575
ACB-2UB461MW
061F9052
ACB-2UC 54W
* Other code numbers are available upon request.
© Danfoss | DCS (rm) | 2019.02 DKRCC.PD.CH0.B8.02 | 520H11785 | 5
Danfoss
61F8025.10
Data sheet | Cartridge pressure switch, type CB
Standard models
(continued)
Application Reset
Auto. 0.5 ± 0.4
Auto.
Low pressure control
Auto.
Auto.
Auto.
Fan
control
Cut out Cut in
[bar]
[psi]
[bar]
[psi]
1.5 ± 0.5
7 ± 6
0.7 ± 0.5 10 ± 7
1.7 ± 0.5 25 ± 7
2.2 ± 0.3
32 ± 4.5
8.5 ± 1.2
125 ± 17
13 ± 1.5
190 ± 22
22 ± 4
1.7 ± 0.4 25 ± 6
2.7 ± 0.4 39 ± 6
3.4 ± 0.3
50 ± 4.5
11 ± 0.8
160 ± 12
16 ± 1
230 ± 14
Contact system /
enclosure type W-water-proof
Solder Flare
types with cable
(IP65)
O-open (spade
connector)
6 mm
types / no cable
(IP00)
SPST-NO / W
061F7518
ACB -2UA518W
SPST-NO / O
SPDT / O
SPST-NO / W
061F7521
ACB-2UA 521W
SPDT / W
SPST-NO / W
SPST-NO / W
061F7524
ACB-2UA524W
061F7418
ACB-2UA711W
061F8491
ACB-2UA393W
SPST-NO / W
061F833 4
ACB-2UA30 6W
Connection type
1
4 in
061F7519
ACB-2UA519W
061F 7402
AC B -2UA152
061F9106
ACB-2UC106
061F7522
ACB-2UA522W
061F7525
ACB-2UA525W
7/16 -20 UN F
with
depressure
pin
061F7520
ACB-2UA520W
061F 7400
AC B -2UA15 0
061F9102
ACB-2UC102
061F7523
ACB-2UA523W
061F9058
ACB-2UC60W
061F7526
ACB-2UA526W
061F8490
ACB-2UA392W
061F8333
ACB-2UA305W
Type CCB
Application Reset
Auto.
High pressure control
Cut out Cut in
[bar]
[psi]
100 ±10
1450 ±145
110±10
159 5±145
120 ±10
1740±145
130±10
1885±145
14 0 ±10
20 30±145
150 ±10
2175 ±145
[bar]
[psi]
70±20
1015±2 90
80±20
1160±290
90±20
1305±290
100 ±20
1450±290
100 ±20
1450±290
100 ±20
1450±290
Contact system /
enclosure type W-water-proof
types with cable
(IP65)
SPST-NC / W
Connection type
Solder 6.35 mm
Packing 100 pcs. Packing 20 pcs.
061F98 08
CCB -2UB03W
061F98 09
CCB -2UB0 4W
061F9810
CCB-2UB05W
061F 9811
CCB -2UB0 6W
061F 9812
CCB -2UB07W
061F 9813
CCB-2UB08W
061F99 08
CCB -2UB03W
061F99 09
CCB -2UB0 4W
061F9910
CCB-2UB05W
6 | 520H11785 | DKRCC.PD.CH0.B8.02
© Danfoss | DCS (rm) | 2019.02
Data sheet | Cartridge pressure switch, type CB
Design / Function
1. Wires
2. Reset button
3. Water-proof casing
4. Diaphragm
5. Pressure connection (1⁄4 in female are)
6. Electrical terminals
7. Micro-switch
8. Shaft
9. Depressure pin
Fig. ACB - SPST manual reset
1
2
3
4
5
6
7
8
9
Special accessories
As pressure is applied through the connection on to the diaphragm, the diaphragm is pushed up against the operation shaft.
When the operation shaft rises, it pushes up
As the pressure in the connection decreases, the diaphragm returns to its original state, and the operation shaft lowers, causing the contact plate to return to its original position.
the contact plate, so that contacts become connected (in normally open) or disconnected (in normally closed).
A wide variety of cartridge switches are available with open enclosure - no electric protection. For these switches a water-proof rubber plug has been specially designed.
Standard cable length [m]* Packing quantity Code no.
2.5 100 061F1302
6 100 061F1304
* other cable lengths available upon request
When the plug is installed on the switch a water-proof seal IP64 is obtained. The water­proof rubber plug is available with many dierent cable lengths.
© Danfoss | DCS (rm) | 2019.02 DKRCC.PD.CH0.B8.02 | 520H11785 | 7
Data sheet | Cartridge pressure switch, type CB
Specication build up Typ e ACB
Requested specs:
Field Code Explanation Product
Product
Electrical rating
Contact
Approvals
Enclosure
Reset
Housing
Port tting
Upper activation setting [bar guage]
Tolerance on upper setting [bar]
ACBExample:
2U B 1 W A R L 20,0 1,0 15,0 1, 5 100 0A
Lower activation setting [bar guage]
Tolerance on low setting [bar]
Electrical connection
Cable l enght in cm
Cable plug
Mark if additional specications
Details of special features (if any)
Electrical rating
Contact
Approvals
Enclosure
Reset
Housing
Port tting
Upper activation setting [bar guage]
Tolerance on upper setting [bar]
Lower activation setting [bar guage]
Tolerance on low setting [bar]
Electrical connection
Cable l enght in cm
Cable plug
Faston A A1: AMP 170213-2, A2: AMP 170213-2, A3: O BR#250, A4: AMP 7352 22-2+AMP 735222-2, A5: AMP 170183-2, A6: A MP 170213-2 AMP B B1: AMP 35 0777-1, B2: AMP 282 080-1, B3: AMP 282104-1, B4: AM P 192167-2, B5: AMP 881772-1, B6: AMP 174354-2 Molex M M1: 5557-02R Pin connector P P1: Phoenix 320 0250, P2: AMP 350218-1, P3: AMP 170213-2+AMP 926933-1, P4: AMP 92 6882-1, P5: AMP 165590-1 Packard Q Q1: 12010973, Q2: 12015792, Q3: 1530 0002, Q4: 153000 27, Q5: 12020829 Stripped end S S1: stripped ends 15mm, S2: stripped ends 10mm VHR V V1: VHR-2N, V2: VHR-3N WAGO W W1: 231-302/026-00 0, W2: 769-102/021-00 0 Additional features
Details of special features (if any)
1U 1A @ 250V AC 2U 6A @ 250V AC (SPST), 4A @ 2 50V AC (SPDT) 4U 0,05A @ 12/24V DC (gold c ontacts)
A SPST-NO B SPST-NC C SPDT
0 CE [category II] approval 1 CE [categ ory II + IV], TÜ V, VDE, UL & C-UL app rovals (only wi th ACB) 2 UL & C-UL approvals (only with ACB) 3 CE [category II + IV] approval (only with ACB)
O Open
W Waterproof IP65 (only with cables)
A Automatic M Manual (not SPST-NO; SPDT only in Panel mount housing)
R Regular hot-melt E Epoxy type P Panel mount (mandatory for SPDT Manual reset versions)
M 1/4” SAE female are w. deator V 1/4” SAE female are w. 1mm deator H 1/4” SAE m ale are P 1/4” solder Cu- tube (tip = 3 mm) X 1/4” solder Cu-t ube (tip = 7 mm) S 1/4” solder Cu -tube (no tip) L 6 mm sol der Cu-tube (ti p = 7mm) E 1/8-27 NPT mal e Y R (PT) 1/8”
--,-
-,- +/- indicated value
--,-
-,- +/- indicated value
A AWG18 cables B AWG16 cables C AWG18 (UL 3173) cabl es S 90 deg. spades D Double insulated AWG18 cables V Double insulated H05VV5-F 2-in-1 cable (on request only, E housing only, Automatic reset only) R Double insulated H05RNF 2-in-1 cable (on request only, E housing only, Automatic reset only) P AWG18 with PVC tube H AWG18 halogen free (RoHS compliant, currently E housing only)
--- Pleas e use one of stan dard lengt hs: 020, 050, 080, 10 0, 150, 200 & 250 cm
(Leave bl ank if no cable)
0 Cut ends
Leave blank if no additional specications
X Please sp ecify (clea r text atta chment)
8 | 520H11785 | DKRCC.PD.CH0.B8.02
© Danfoss | DCS (rm) | 2019.02
Data sheet | Cartridge pressure switch, type CB
Heat proofelectricvinyl wire
33
24
16.4 ±1.5
7/16-20 unffor flare
Hex14
With depressorpin
UL1015, AWG18,105 ºC (Black)
1500±50
Label
ø23.5
Danfoss
61F015.10
24
33
ø23.5
Heatproof electric vinylwire UL1015, AWG18,105 ºC (Black)
58.2
3
ø6.35±0.1
(ø8)
1500 ±50
Label
Danfoss
61F014.10
Danfoss
61F004.10
24
33
ø23.5
58.2
7
(ø7)
ø6 ±0.1
ø6.35±0.1
1500±50
Label
Heat proofelectricvinyl wire UL1015, AWG18,105 ºC (Black)
Danfoss
61F016.10
Danfoss
61F006.10
Danfoss
61F007.10
Dimensions [mm] andweights [kg]
Type ACB – SPST water-proof with automatic reset 1⁄4 in solder type
Type ACB – SPST water-proof with automatic reset female are
Net weight 0.072 kg Net weight 0.080 kg
Type ACB – SPST water-proof with manual reset solder type
Type ACB – SPST water-proof with automatic reset 6 mm solder type
© Danfoss | DCS (rm) | 2019.02 DKRCC.PD.CH0.B8.02 | 520H11785 | 9
Net weight 0.078 kg Net weight 0.072 kg
Type ACB – SPDT with automatic reset Type ACB –SPDT with manual reset
Net weight 0.114 kg
Net weight 0.112 kg
Danfoss
61F008.10
Danfoss
61F009.10
(24.5)
φ6.35±0.1
UL1015, AWG18, 105 °C (BLACK)
HEAT PROOF ELECTRIC VINYL WIRE
8
+1
0
44±257.7±2
LABEL
Danfoss
61F001.10
1500±50
Dimensions [mm] andweights [kg]
(continued)
Type ACB – SPDT open type solder type Type ACB – SPST open type with female are
Net weight 0.024 kg Net weight 0.029 kg
Type CCB - SPST water-proof with automatic reset 6.35 mm solder type
© Danfoss | DCS (rm) | 2019.02 DKRCC.PD.CH0.B8.02 | 520H11785 | 10
Net weight 0.125 kg