Návod k použití Kompresory VSH
Regulační ventil vstřikování oleje
A
|
B |
|
|
|
|
|
|
|
|
|
|
D |
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
E |
||
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C |
|
|
|
|
|
|
|
|
|
|
|
F |
|
|
|
|
|
|
|
|
|
|
|
|
||
A: |
|
|
E: |
|
|
|
|
|
|
G |
|||
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|||
Číslo modelu |
Provozní tlak tělesa kompresoru |
||||||||||||
B: |
Výrobní číslo |
F: |
Olej plněný při výrobě |
||||||||||
C: |
Chladivo |
G: |
Kmitočet kompresoru & Max. vypínací |
||||||||||
D: |
Napájecí napětí & Proud při zabrzděném ro- |
|
proud |
||||||||||
toru |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
R410A |
|
|
|
|
|
|
70 |
|
|
|
|
|
|
|
|
|
|
|
65 |
|
|
|
|
|
|
50 - 90 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
60 |
|
|
SH=6K |
|
|
|
|
|
|
|
|
55 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>(°C) |
50 |
|
|
|
|
|
|
|
|
|
|
45 |
|
|
|
|
30 - 90 Hz |
|
|
|
|
||
<![if ! IE]> <![endif]>C |
|
|
<![if ! IE]> <![endif]>Hz |
|
|
|
|
|
|
||
<![if ! IE]> <![endif]>T |
40 |
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
||
|
35 |
|
<![if ! IE]> <![endif]>- 90 |
|
|
|
|
|
|
|
|
|
30 |
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>50 |
|
|
|
|
|
|
|
|
|
|
25 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
20 |
|
|
|
|
|
|
|
|
|
|
|
15 |
|
|
|
|
|
|
|
|
|
|
|
-30 |
-25 |
-20 |
-15 |
-10 |
-5 |
0 |
5 |
10 |
15 |
20 |
|
|
|
|
|
|
T0 (°C) |
|
|
|
|
|
Sestavení systému řízení vstřikování oleje
3 2 |
1 |
4 |
5 |
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
220V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
2 A max |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
||||||||
Nasaďte (naklapněte) cívku (1) s těsněním (2) na |
Připojte konektor (4) k cívce pomocí dodaného |
Zapojte konektor dle tohoto schématu. |
|||||||||||||||||
těleso ventilu (3) na kompresoru. |
příslušenství (5) a (6). |
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Demontáž cívky systému řízení vstřikování oleje |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sundejte nacvakávací cívku pomocí šroubováku.
Kompresor smí být použit pouze k účelům pro něž byl konstruován a v mezích povoleného rozsahu tlaků a teplot (viz„Rozsah použití”).
Další informace naleznete v Pokynech k použití a v technických listech, které jsou k dispozici na http://cc.danfoss.com.
Za všech okolností musí být splněny požadavky normy EN378 (nebo jiných platných místních bezpečnostních předpisů).
Kompresor je dodáván naplněný stlačeným plynným dusíkem (s přetlakem mezi 0,3 a 0,7 baru) a nelze jej proto přímo připojit ve stavu, v jakém byl dodán; další informace naleznete v části„montáž”.
S kompresorem je třeba zacházet opatrně a přemísťovat jej ve svislé poloze (max. odchylka od svislé polohy: 15°).
1 |
FRCC.EI.005.A3.48 © Danfoss Commercial Compressors 09/10 |
|
Návod k použití
-Skutečná poloha jednotlivých konektorů závisí na verzi frekvenčního měniče a může se lišit od níže uvedeného schématu.
-Vždy se ujistěte, zda jsou svorky kompresoru T1, T2, T3 spojeny se svorkami frekvenčního měniče 96, 97, 98.
-Motorový kabel kompresoru musí být stíněný
|
|
|
|
|
|
|
|
|
|
|
|
|
|
L1 |
|
|
|
|
91 |
|
L1 |
|
|||||
|
|
|
|
|
|||||||||
L2 |
|
|
|
|
92 |
|
L2 |
|
|||||
|
|
|
|
||||||||||
L3 |
|
|
|
|
93 |
|
L3 |
|
|||||
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
95 |
|
PE |
|
||||
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
39 |
39 |
Ana out COM |
|
|
|
|
|
|
|
|
|
|
|
42 |
42 |
Ana out + |
<![if ! IE]> <![endif]>CDS302 |
|
|
|
|
|
|
|
|
|
|
50 |
50 |
Ana in +10 V |
|
|
|
|
|
|
53 |
53 |
Ana in 0 ± 10 V |
|
|||||
|
|
|
|
|
54 |
54 |
Ana in 0 ± 10 V |
|
|||||
|
|
|
|
|
55 |
55 |
Ana in COM |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
12 |
12 |
+24V |
|
||
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
13 |
13 |
+24V |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
18 |
18 |
Dig in |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
19 |
19 |
Dig in |
|
|
|
|
|
|
|
|
|
|
27 |
27 |
Dig in/out |
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
29 |
29 |
Dig in/out |
|
|
|
|
|
|
32 |
32 |
Dig in |
|
|||||
|
|
|
|
|
33 |
33 |
Dig in |
|
|||||
|
|
|
|
|
20 |
20 |
Dig in COM |
|
|||||
|
|
|
|
|
|
|
|
|
|
37 |
37 |
Dig in |
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Základní zapojení
(pancéřovaný) a stínění musí být uzemněno na obou koncích kabelu, tj. na straně kompresoru i na straně frekvenčního měniče.
-Pro instalaci kabelů a jejich dokonalé uzemnění použijte kabelové průchodky splňující podmínky elmg. kompatibility. Ko-
vová svorkovnice kompresoru má kolem
W |
98 |
|
T3 |
||
|
|||||
V |
97 |
|
T2 |
||
|
|||||
U |
96 |
|
T1 |
||
|
|||||
|
|
|
|
|
|
PE |
99 |
|
|
|
|
NC |
<![if ! IE]> <![endif]>1 |
03 |
|
|
|
|
|
|
|
|
NO |
<![if ! IE]> <![endif]>RELAY |
02 |
|
|
|
|
|
|
|
230 V |
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
COM |
|
01 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 A max |
||
|
|
|
|
|
|
|
|
|||
NC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>2 |
06 |
|
|
|
|
|
|
|
|
|
COM |
<![if ! IE]> <![endif]>RELAY |
|
|
|
|
|
|
|
|
|
04 |
|
|
|
|
|
|
|
|
||
NO |
|
05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N- RS485 |
69 |
69 |
P+ RS485 |
68 |
68 |
COM RS485 |
61 |
61 |
připojovacího otvoru povrch bez nátěru, aby byla zajištěna lepší vodivost.
-Povinným použitím nízkotlakého presostatu musíte zabránit provozu kompresoru při příliš nízkém tlaku.
-Při spuštění ověřte, zda se kompresor otáčí správným směrem a vytváří tlak.
Legenda: |
|
Ana: |
Analogový |
Dig: |
Digitální |
in: |
Vstup |
out: |
Výstup |
COM: |
Společná |
NC: |
Rozpínací |
NO: |
Spínací |
|
|
Bez zpětné vazby |
Se zpětnou |
|
|
|
vazbou |
91, 92, 93: |
3fázový síťový vstup |
X |
X |
95: |
Uzemnění |
X |
X |
39, 42 |
Analogový výstup |
- |
- |
50: |
Analogový vstup |
- |
- |
53: |
PLC+ (0 až 10 V) |
X |
- |
54: |
Čidlo - |
- |
X |
55: |
PLC- |
X |
- |
12: |
Přepínač VT/NT |
X |
X |
12: |
Externí vypínač (spínací) |
X |
X |
13: |
Přemostěno z výroby na sv. 37 |
X |
X |
13: |
Čidlo + |
- |
X |
18: |
Externí vypínač (spínací) |
X |
X |
19: |
Digitální vstup |
- |
- |
27: |
Přepínač VT/NT (rozpínací) / bezpečnostní zařízení |
X |
X |
29: |
Digitální vstup/výstup |
- |
- |
32, 33 |
Digitální vstup |
- |
- |
20: |
Digitální vstup, společný |
- |
- |
37: |
Přemostěno z výroby na sv. 13 |
X |
X |
98: |
Na svorku kompresoru T3 |
X |
X |
97: |
Na svorku kompresoru T2 |
X |
X |
96: |
Na svorku kompresoru T1 |
X |
X |
99: |
Na uzemnění kompresoru |
X |
X |
02, 01: |
Relé 1 na elmg. olejový ventil |
X |
X |
06, 05, 04: |
Relé 2 |
- |
- |
69, 68: |
Sběrnice RS485 |
- |
- |
61: |
Společná sběrnice RS485 |
- |
- |
Frekvenční měnič CDS302 je z výroby předem nastaven s parametry pro řízení bez zpětné vazby. Řízení se zpětnou vazbou je možné zvolit změnou parametrů v„Rychlém menu”.
Bez zpětné vazby: řízení 0 - 10 V
Frekvenční měnič v režimu„slave“
Řízení procesu: řízení 4 - 20 mA
Frekvenční měnič je řízen vlastním PID regulátorem.
- |
Volitelné připojení |
X : Povinné připojení |
2 |
FRCC.EI.005.A3.48 © Danfoss Commercial Compressors 09/10 |