Danfoss VSB 06-EN Technical Information

Danfoss VSB 06-EN Technical Information

Relief Valves Technical Information

Differential Area

VSB 06-EN

OPERATION

This is a direct-acting, differential area, poppet-type relief valve that relieves from 2 to 1

 

with an integral free-flow check from 1 to 2.

 

SPECIFICATIONS

Theoretical performance

Schematic

 

psi

bar

26 mm²/sec (cSt) [124 SUS] @ 50°C [122° F]

 

 

 

400

 

 

 

 

 

 

5000

 

 

 

 

4000

300

 

 

 

 

 

 

 

3000

200

 

 

 

2000

 

 

 

 

 

100

 

 

1000

00

l/min

Minimum setting

value

 

Specifications

 

80

Rated pressure

350 bar [5075 psi]

 

 

20

40

60

 

 

Rated flow

80 l/min [21 US gal/min]

 

 

 

 

 

0

5

10

15

20

Weight

0.22 kg [0.49 lb]

 

Flow

US gal/min

 

 

 

 

 

Cavity

NCS06/2

 

 

 

 

 

DIMENSIONS

Cross-sectional view

 

mm [in]

 

 

27 mm

 

 

44-50 N m

M 22 x 1.5

 

[32-37 lbf ft]

 

1

2

69.0

31.0

[2.72]

[1.21]

ORDERING

INFORMATION

VSB 06-EN - 1 - 00 - V - XXX

Setting range

1 = 20 - 80 bar [363 - 2031 psi]

2 = 70 - 210 bar [1015 - 3046 psi] 3 = 105 - 350 bar [15235076 psi]

 

 

 

 

Seals

Seal Kit

 

 

 

 

 

 

 

 

V = Viton

230000380

 

 

Omit = Buna-N

230000060

Housing and po rts

Housing P/N

00

= No Housing

No Housing

DG3/8

= AL, 3/8 BSP

NCS06/2-DG-3/8

DG1/2

= AL, 1/2 BSP

NCS06/2-DG-1/2

DG6S

= AL, #6 SAE

NCS06/2-DG-6S

DG8S

= AL, #8 SAE

NCS06/2-DG-8S

Other housings available

To order this valve with a speci c factory setting, contact your Danfoss ICS representative

BC332375370104en-000101 • February 2020

RV - 24