Flow Control Valves Technical Information
US gal/min
26 cSt [125 SUS] hyd.oil @ 20° C [68° F]
0
Pressure
P103 695E
Fixed Setting, Priority Type
VRF 06
OPERATION
SPECIFICATIONS
DIMENSIONS
mm in
This valve is a xed, pressure
compensated, priority-type ow control.
Theoretical performance
l/min
8
30
25
6
20
15
4
10
2
5
0
0
bar
psi
90 135 225 315
45 180 270
900 1800 2700 4500
Cross-sectional view
Schematic
Specications
Rated pressure 315 bar [4500 psi]
Max regulated ow 26 l/min
[7 US gal/min]
Max inlet ow 50 l/min
[13 US gal/min]
Weight 0.19 kg [0.42 lb]
Accuracy ± 10% 2.3-25.5 l/min
[0.5-6.8 US gal/min]
Cavity NCS06/3
27 mm
44-50 Nm
[32-37 lbf ft]
ORDERING
INFORMATION
M22x1.5
29.0
[1.14]
3
46.0
[1.81]
2
1
P103 667
VRF 06 - 1.5 - SE3/8 -V
Orifice size
Orifice flow
L/min [US gal/min]
0.75 = 1.5 [0.4]
1.00 = 2.0 [0.53]
1.25 = 3.5 0.92[]
1.50 = 4.5 [1.19]
1.75 =6 [1.58]
2.00 = 9.0 [1.38]
2.25 =10 [2.64]
2.50 =12 [3.30]
2.75 =15 [3.96]
3.00 =18 [4.75]
3.25 = 21.5 [5.68]
3.50 =25 [6.73]
Housing and portsHousing P/N
00 =No Housing No Housing
SE3/8 = AL, 3/8 BSP NCS06/3-SE-3/8
SE1/2 = AL, 1/2 BSP NCS06/3-SE-1/2
SE6S = AL, #6 SAE NCS06/3-SE-6S
SE8S = AL, #8 SAE NCS06/3-SE-8S
Other housings available
Seals
V =Viton
Omit = Buna-N
Seal kit
230000110
230000070
P103 722E
BC332375569107en-000101 • February 2020
FC - 28