Installation guide
Non-return valve
VCM 92
1. Identication &
Installation
180R9416
Check Valve
Type VCM 92
Code no. 180H0058
Serial no. XXXXXX04-XXX
180R9416
MADE IN DENMARK
Danfoss A/S, 6430 Nordborg, Denmark
The non-return valve is designed for use in Seawater
Reverse Osmosis (SWRO) membrane systems. In case
the high-pressure pump stops momentarily, the
volume of water in the membrane vessel may work
as an accumulator and will send ow backwards.
When using multiple pumps in parallel, the
non-return valve prevents the water from one
pump to run into the parallel-coupled pumps at
start-up. The valve is prepared for easy installation on the high-pressure outlet of APP 53-92
series 08 or higher.
Use only Style 77DX coupling or equivalent.
Typ e Outlet
Connection
VCM 92 3" Victaulic
OSG
1)
The check valve is mounted directly in the outlet port with a ange with 6 bolts (M10 x 25)
2)
Wettet parts materials: Super Duplex, PEEK, PP, Hastelowy, FKM, NBR
3)
The installation instruction for Style 77DX is located in the Victaulic document I-100 Field Installation
3)
Diameter
1)
mm (inch)
87. 7
(3.45)
Length
mm (inch)
180.5
(7.10 )
Material
Super
Duplex
2)
Max.
pressure
barg (psig)
80
(1,160)
Flow
continuoulu
m3/h (gpm)
92
(405)
Code
number
180H0058
Handbood (http://static.victaulic.com)
© Danfoss | DCS (im) | 2019.10
180R9416 | AN320151709784en- 000101 | 1
2. Installation
2.1 Mounting holes and torque
The VCM 92 check valve comes with a ange connection that is easily mounted directly on the
pump outlet port (outlet connection is not
required).
When installing the valve, lubricate the O-ring at
the ange before pushing it into the outlet of the
pump.
Note: Bolts must be tightened with torque
95Nm ± 9.5 Nm.
© Danfoss | DCS (IM) | 2019.10
180R9416 | AN320151709784en- 000101 | 2