Danfoss VCM 92 Data sheet

Data sheet
Data sheet
Non return valve
Non return valve
VCM 92 3” Vic. outlet
VCM 86 3” Vic outlet
ro-solutions.com
Data sheet | Non return valve VCM 92
Table of Contents
1. Introduction
1. Introduction ............................................................................2
2. Features ................................................................................2
3. Technical data and code numbers .......................................................2
4. Filtration................................................................................3
5. Dimensions .............................................................................3
6. Flow versus pressure charts .............................................................4
The non-return valve is designed for use in Seawater Reverse Osmosis (SWRO) membrane systems. In case the high-pressure pump stops momentarily, the volume of water in the membrane vessel may work as an accumulator and will send ow backwards. In case pumps are
placed in parallel, the non-return valve also prevents that water from one pump runs into the parallel-coupled pumps at start-up. The function of the valve is prepared for easy installation on the high-pressure outlet. Typically used in connection with APP 53 - 92 pumps.
3. Technical data and code numbers
VCM 92
The non return valve is designed for use with low
The sealing is a FKM 75 O-ring.2. Features
viscosity and corrosive uids such as sea water.
All wetted parts are made of highly corrosion resistant materials such as Super Duplex (EN1.4410/UNS S32750/SAF 2207) stainless steel and carbon reinforcec PEEK.
Typ e Max.
pressure
barg (psig)
VCM 92 83 (1200) 92 (405) 0.05 (7.2) 0.4 (7.8)
Flow continuously
m³/h (gpm)
Opening pressure
barg (psig)
Pressure loss at max. ow barg (psig)
Inlet connection
Flange with
8 screws
M12x25
Net weight: 5.2 kg (11.4 lb) Materials: Superduplex, PEEK, PP, Hasteloy, FKM, NBR Min. ow continuous: 20 m³/h (88 gpm)
Outlet connection
Victaulic 3” 180H0058