Data Sheet | Non return valve VCM 22
Introduction
Features
Technical data
and code numbers
Filtration
The function of the non-return valve to be mounted directly on the outlet of the APP pump is to
protect the pump by allowing ow out of the pump while blocking ow into the pump.
The valve incorporates a conical poppet design, which ensures sealing when used with a low viscosity
medium such as water.
Typically used in connection with APP 21 - 30 and APP 22 pumps.
The non-return valve is produced in stainless Super Duplex W. Nr. 1.4410. The connection sealing is an
O-ring made of Viton.
The valve is available for ows up to 22 m3/h or 370 l/min (97 gpm).
Type
VCM 22 80 (1160) 370 (97) 0.3 (4.3) 0.5 (7.3)
Max.
pressure
bar (psi)
Flow
continuously
l/min (gpm)
Opening
pressure
bar (psi)
Pressure loss
at max. ow
bar (psi)
Inlet
connection
M52 x 1,5
(63mm)
Outlet
connection
Vic. 2” 180H0256
number
Code
The uid must be clean and free from abrasive sediments.
2 | © Danfoss | DCS (im) 2019.09
AI318246693759en-000201