Danfoss VCM 22 Data sheet

Data Sheet
Non return valve
VCM 22 2” Vic. outlet
hpp.danfoss.com
Data Sheet | Non return valve VCM 22
Features
Technical data and code numbers
Filtration
The function of the non-return valve to be mounted directly on the outlet of the APP pump is to protect the pump by allowing ow out of the pump while blocking ow into the pump. The valve incorporates a conical poppet design, which ensures sealing when used with a low viscosity medium such as water. Typically used in connection with APP 21 - 30 and APP 22 pumps.
The non-return valve is produced in stainless Super Duplex W. Nr. 1.4410. The connection sealing is an O-ring made of Viton. The valve is available for ows up to 22 m3/h or 370 l/min (97 gpm).
Type
VCM 22 80 (1160) 370 (97) 0.3 (4.3) 0.5 (7.3)
Max.
pressure
bar (psi)
Flow
continuously
l/min (gpm)
Opening pressure
bar (psi)
Pressure loss
at max. ow
bar (psi)
Inlet
connection
M52 x 1,5
(63mm)
Outlet
connection
Vic. 2” 180H0256
number
Code
The uid must be clean and free from abrasive sediments.
2 | © Danfoss | DCS (im) 2019.09
AI318246693759en-000201