Danfoss vacon nx optcp User guide

vacon nx
ac drives
optcp
profinet option board
user manual
2 • vacon
INDEX
Document code: DPD00895A
Last edited: 27.01.2012
1. Introduction ....................................................................................................................... 3
2. Ethernet board technical data ............................................................................................ 4
2.1. Overview .................................................................................................................................... 4
2.2. LED indications ......................................................................................................................... 5
2.3. Ethernet .................................................................................................................................... 6
2.4. Connections and wiring ............................................................................................................. 7
3. Installation ......................................................................................................................... 8
3.1. Installing the Ethernet Option Board in a Vacon NX Unit ......................................................... 8
3.2. NCDrive ................................................................................................................................... 10
3.3. IP Tool NCIPConfig .................................................................................................................. 10
3.4. Example with Siemens PLC .................................................................................................... 14
4. Commissioning ................................................................................................................ 23
4.1. Expander board menu (M7) ..................................................................................................... 23
4.2. Profinet parameters................................................................................................................ 23
4.3. IP Address ............................................................................................................................... 23
4.4. Start-up test ............................................................................................................................ 24
5. Profinet IO ........................................................................................................................ 25
5.1. Vendor profile .......................................................................................................................... 25
5.2. Bypass profile ......................................................................................................................... 30
5.3. Profidrive profile ..................................................................................................................... 31
5.4. Parameter channel ................................................................................................................. 35
5.5. Parameter data transfer examples ........................................................................................ 39
6. APPENDIX ........................................................................................................................ 40
2
Introduction vacon • 3
1.

INTRODUCTION

Vacon NX frequency converters can be connected to Ethernet using an Ethernet fieldbus board OPTCP.
The OPTCP can be installed in board slots D or E.
Every appliance connected to an Ethernet network has two identifiers; a MAC address and an IP ad­dress. The MAC address (Address format: xx:xx:xx:xx:xx:xx ) is unique to the appliance and cannot be changed. The Ethernet board's MAC address can be found on the sticker attached to the board or by using the Vacon IP tool software NCIPConfig. You can find the software installation at www.vacon.com
In a local network, IP addresses can be defined by the user as long as all units connected to the net- work are given the same network portion of the address. For more information about IP addresses, contact your Network Administrator. Overlapping IP addresses cause conflicts between appliances. For more information about setting IP addresses, see Section 3, Installation.
WARNING!
Internal components and circuit boards are at high potential when the frequency converter is connected to the power source. This voltage is extremely dangerous and may cause death or severe injury if you come into contact with it.
24-hour support +358 (0)40 837 1150 • Email: fieldbus@vacon.com
1
Loading...