Danfoss vacon nx Installation guide

vacon nx
®
ac drives
ip54 control box
installation instructions
index
Document code: DPD01614A
Date: 1.7.2014
1. CONTENTS OF THE DELIVERY ............................................................................................ 2
2. INSTALLATION ................................................................................................................... 3
2.1 Optic fibre cable, signal listing and connections ....................................................................... 5
2.2 Cable bushing diameters ........................................................................................................... 6
24-hour support +358 (0)40 837 1150 • Email: vacon@vacon.com
2 • vacon CONTENTS OF THE DELIVERY
1
1
2
3
4
5

1. CONTENTS OF THE DELIVERY

Figure 1. Contents of the IP 54 control box delivery
1 IP54 control box 2 IP54 cable entry grommet plates 3 Grease for the grommet plates
4 Screws (4x10)
5 Plastic pins
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
2

2. INSTALLATION

These instructions guide you through the installation of the IP54 control box that you have purchased for your FR12, FR14, FI12, FI14, CH64 or CH74 size frequency converter.
1. IP54 control box bottom plate with starcoupler board
2. Connect the fibre optic cables. Push carefully the cables into the cellfoam bushings
5. Close the cover by pushing it carefully down so that the D-connector connects thoroughly.
3. Each fibre optic cable has a number
1...8 and 11…18 marked on the cable shield at both cable ends. Connect each cable to the connectors marked with the same number on the starcoupler board. The list of the optic signals can be found in chapter 2.1
6. Attach the cover with four screws (tightening torque 1,5 nm)
4. Connect the 24 V cable and lead it through the bushing as shown in the figure.
7. Apply a thin layer of grease to the cellfoam washers
8. Push the cellfoam washer into the guides in the enclosure.
24-hour support +358 (0)40 837 1150 • Email: vacon@vacon.com
9. Open the bushing for the cable. Pull away the right size of piece according to the cable size (in this figure 8 mm).
4 • vacon INSTALLATION
2
10. Push the cable to the bushing. Make sure that the cellfoam surrounds the cable tightly.
13. Attach the seal around the RS485 connector.
11. Attach the cable to the washer with a plastic binder
14. Attach the cover plate with four screws
12. Apply some grease to the upper cellfoam washer and push it to its place.
15. Seal the holes with a piece of tape and attach the RS485 cable
16. Push the plastic pins to the unused cable entries .
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
2
Star coupler board on control unit
H18 Trip signal from power module 2 H17 VaconBus data from ASIC 2 to control board H16 VaconBus data from control board to ASIC 2 H15 ADC synchronization, power module 2 H14 Phase W control, power module 2 H13 Phase V control, power module 2 H12 Phase U control, power module 2 H11 Gate control enable, power module 2
H23
Feedback phase W
H22
Feedback phase V
H21
Feedback phase U
Terminals on ASIC board of power module 1
H1 Gate control enable H2 Phase U control H3 Phase V control H4 Phase W control H5 ADC synchronization H6 VaconBus data from control board to ASIC H7 VaconBus data from ASIC to control board
Terminals on ASIC board of power module 2
H8 Trip signal from power module 1 H7 VaconBus data from ASIC 1 to control board H6 VaconBus data from control board to ASIC 1 H5 ADC synchronization, power module 1 H4 Phase W control, power module 1 H3 Phase V control, power module 1 H2 Phase U control, power module 1 H1 Gate control enable, power module 1
H10 Trip signal
Terminals on FB board of power module 2
H1 Gate control enable H2 Phase U control H3 Phase V control H4 Phase W control H5 ADC synchronization H6 VaconBus data from control board to ASIC H7 VaconBus data from ASIC to control board
H10 Trip signal H11 Feedback phase U H12 Feedback phase V H13 Feedback phase W
Terminals on FB board of power module 1
H12
H13
H14
H15
H16
H17
H18
H11
H23
H22
H21
H2
H3
H4
H5
H6
H7
H8
H1
H7
H6
H5
H4
H3
H2
H1
H10
H7
H6
H5
H4
H3
H2
H1
H10
H13
H12
H11

2.1 Optic fibre cable, signal listing and connections

Figure 2. Internal fibre cable connections
24-hour support +358 (0)40 837 1150 • Email: vacon@vacon.com
6 • vacon INSTALLATION
2

2.2 Cable bushing diameters

Figure 3. Cable bushing diameter
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
Find your nearest Vacon office
on the Internet at:
www.vacon.com
Manual authoring: documentation@vacon.com
Vacon Plc. Runsorintie 7 65380 Vaasa Finland
Subject to change without prior notice © 2014 Vacon Plc.
Document ID:
Rev. A
Sales code: DOC-INSIP54BOX+DLUK