Danfoss TFS4F Data sheet

TFS4F Standard Compressor R134a 115-127V 60Hz
General
Code number 102G3431
Approvals UL984
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °F -31 to 14
Voltage range V 95 - 135
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (257)
Cooling requirements
Frequency Hz 50 60
Application
90°F S
100°F S
110°F S
Remarks on application:
Motor
Motor type RSIR
LRA (rated after 4 sec. UL984), HST | LST A 18.9
Cut in Current, HST | LST A 18.9
Resistance, main | start winding (77°F) 3.8 7.8
Design
Displacement cu.in 0.23
Oil quantity (type) .oz. 6.1 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 60.6
Weight without electrical equipment lbs. 16.5
Dimensions
Height inch A 6.81
Suction connector location, I.D. in. | angle C 0.252-0.259 | 30°
material | comment Cu-plated steel | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 31.5°
material | comment Cu-plated steel | Rubber plug
Discharge connector location, I.D. in. | angle E 0.202-0.205 | 28°
material | comment Cu-plated steel | Rubber plug
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
B 6.65
B1
B2
S = Static cooling normally sufcient O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.A7.22 / 520N1355 1/2
ASHRAE LBP 115V, 60Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 155 237 315 355 506 697 782
Power cons. in W 60 79 92 97 114 132 139
Current cons. in A 1.46 1.53 1.59 1.62 1.71 1.82 1.87
EER in BTU/Wh 2.58 3.00 3.44 3.66 4.43 5.28 5.62
EN 12900 Household (CECOMAF) 115V, 60Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 37 56 75 85 120 166 186
Power cons. in W 60 79 92 97 114 132 139
Current cons. in A 1.46 1.53 1.59 1.62 1.71 1.82 1.87
COP in W/W 0.61 0.71 0.82 0.87 1.05 1.26 1.34
Accessories for TFS4F Figure Code number Test conditions
Starting relay (protector incl.)
Protector 3/4“ Texas Instruments MRP57JK-6 Ambient temp. 90°F 90°F
Protector 3/4“ Electrica T 0727/06 Suction gas temp. 90°F 90°F
Cover b 117U1021 Liquid temperature 90°F 131°F
Cord relief d 117U0349
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.A7.22 / 520N1355 June 2012
a2
117U4122 Condensing temp. 130°F 131°F
Mounting accessories Code number
Bolt joint for one comp. Ø: 5 /8 i n. 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
ASHRAE
LBP
EN 12900/
CECOMAF