Danfoss Termix BV Operating guide

Page 1
OperatingGuide
TermixBV

1.0TableofContents

1.0TableofContents.............................................1
........................................................................2
2.0Functionaldescription......................................3
3.0Safetynotes.....................................................4
3.1SafetyNotes–general............................................4
4.0Mounting........................................................5
4.2Electricalconnections.............................................7
5.0Design.............................................................8
5.1Design...............................................................8
5.3Design...............................................................10
5.4Schematicdiagram................................................11
6.0Controls..........................................................12
6.1DHWtemperaturecontrol........................................12
6.2Other.................................................................15
6.3Maintenance........................................................16
7.0Troubleshooting..............................................17
7.1Troubleshootingingeneral......................................17
7.2TroubleshootingDHW............................................18
7.3Disposal.............................................................19
8.0Declaration......................................................23
8.1Declarationofconformity........................................23
©Danfoss|2019.01VI.EH.C5.02/LUK41500|1
Page 2
OperatingGuideTermixBV
2|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 3
OperatingGuideTermixBV

2.0Functionaldescription

Instantaneouswaterheaterwithheatexchangerand thermostaticorautomaticcontrols.Designedfor wall-mounting.
Application
TheTermixBVsubstationisaninstantaneouswaterheater featuringsuperbheatextractionandhighperformance.The substationisdeliveredwiththermostaticorautomaticcontrols. TheTermixBVissuitableforlargeapartmenthouses,sportsarenas andschools,wherelargeamountsofhotwaterareneeded.The hotwatersystemsareavailablein7differentsizeswithanoutput from77-265kW.TheTermixBVunitissuppliedwithPUinsulated heatexchangers.
Domestichotwater(DHW)
Thedomestichotwaterispreparedinaplateheatexchanger andthetemperatureisregulatedwiththermostaticorautomatic controls.Thethermostaticsolutionisregulatedwithself-acting thermostaticcontrolvalves.Thesubstationswithhighoutputare controlledwithtwovalvesconnectedincascadeinordertocontrol bothsmallandlargedemandsforhotwaterinanefficientmanner. TheT ermixBVcanalsobemountedwithautomaticcontrols. Thereisnoadditionalpressurelossonthesecondarysideofthe heatexchangerwithathermostaticorautomaticcontrolvalve. Thereforethistypeofregulationcanbeusedbylowpressureinthe coldwatermains.
Domestichotwatercirculation
TheTermixBVsubstationissuppliedwithconnectionsforDHW circulationincludingcirculationpumpandanonreturnvalveas astandard.
VI.EH.C5.02/LUK41500
©Danfoss|2019.01|3
Page 4
OperatingGuideTermixBV

3.0Safetynotes

3.1SafetyNotes–general

Thefollowinginstructionsrefertothestandarddesignof substation.Specialversionsofsubstationsareavailableon request.
Thisoperatingmanualshouldbereadcarefullybeforeinstallation andstart-upofthesubstation.Themanufactureracceptsno liabilityfordamageorfaultsthatresultfromnon-compliancewith theoperatingmanual.Pleasereadandfollowalltheinstructions carefullytopreventaccidents,injuryanddamagetoproperty. Assembly,start-upandmaintenanceworkmustbeperformedby qualifiedandauthorizedpersonnelonly. Pleasecomplywiththeinstructionsissuedbythesystem manufacturerorsystemoperator.
Corrosionprotection
Allpipesandcomponentsaremadeofstainlesssteelandbrass. Themaximumchloridecompoundsoftheflowmediumshouldnot behigherthan150mg/l. Theriskofequipmentcorrosionincreasesconsiderablyifthe recommendedlevelofpermissiblechloridecompoundsis exceeded.
Energysource
Thesubstationisdesignedfordistrictheatingastheprimary sourceofenergy.However,alsootherenergysourcescanbeused wheretheoperatingconditionsallowitandalwaysarecomparable todistrictheating.
Application
Thesubstationisdesignedtobeconnectedtothehouse installationinafrost-freeroom,wherethetemperaturedoesnot exceed50°Candthehumiditydoesnotexceed60%.Donotcover orwallupthesubstationorinanyotherwayblocktheentrance tothestation.
Authorizedpersonnelonly
Assembly,start-upandmaintenanceworkmustbeperformedby qualifiedandauthorizedpersonnelonly.
Pleaseobserveinstructionscarefully
Toavoidinjurytopersonsanddamagetothedevice,itisabsolutely necessarytoreadandobservetheseinstructionscarefully.
Warningofhighpressureandtemperature
Beawareoftheinstallation’spermissiblesystempressureand temperature.
Themaximumtemperatureoftheflowmediuminthesubstationis 120°C.
Themaximumoperatingpressureofthesubstationis16bar.
Theriskofpersonsbeinginjuredandequipmentdamagedincreases considerablyiftherecommendedpermissibleoperatingparameters areexceeded.
Thesubstationinstallationmustbeequippedwithsafetyvalves, however,alwaysinaccordancewithlocalregulations.
Choiceofmaterial
Choiceofmaterialsalwaysincompliancewithlocallegislation.
Safetyvalve(s)
Werecommendmountingofsafetyvalve(s),however,alwaysin compliancewithlocalregulations.
Connection
Thesubstationmustbeequippedwithfeaturesthatensurethat thesubstationcanbeseparatedfromallenergysources(also powersupply).
Emergency
Incaseofdangeroraccidents-fire,leaksorotherdangerous circumstances-interruptallenergysourcestothestationif possible,andseekexperthelp. Incaseofdiscolouredorbad-smellingdomestichotwater,closeall shut-offvalvesonthesubstation,informtheoperatingpersonnel andcallforexperthelpimmediately.
REACH
AllDanfossA/SproductsfulfilltherequirementsinREACH. OneoftheobligationsinREACHistoinformcustomersabout presenceofCandidatelistsubstancesifany,weherebyinform youaboutonesubstanceonthecandidatelist:Theproduct containsbrasspartswhichcontainslead(CASno:7439-92-1)ina concentrationabove0.1%w/w.
Storage
Anystorageofthesubstationwhichmaybenecessarypriorto installationshouldbeinconditionswhicharedryandheated.
Warningofhotsurface
Thesubstationhasgothotsurfaces,whichcancauseskinburns. Pleasebeextremelycautiousincloseproximitytothesubstation.
Powerfailurecanresultinthemotorvalvesbeingstuckinopen position.Thesurfacesofthesubstationcangethot,whichcancause skinburns.Theballvalvesondistrictheatingsupplyandreturnshould beclosed.
Warningoftransportdamage
Beforesubstationinstallation,pleasemakesurethatthesubstation hasnotbeendamagedduringtransport.
IMPORTANT-Tighteningofconnections
Duetovibrationsduringtransportallflangeconnections,screwjoints andelectricalclampandscrewconnectionsmustbecheckedand tightenedbeforewaterisaddedtothesystem.Afterwaterhasbeen addedtothesystemandthesystemhasbeenputintooperation, re-tightenALLconnections.
4|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 5
OperatingGuideTermixBV

4.0Mounting

4.1Mounting

Installationmustbeincompliancewithlocalstandardsand regulations. Districtheating(DH)-Inthefollowingsections,DHreferstothe heatsourcewhichsuppliesthesubstations.Avarietyofenergy sources,suchasoil,gasorsolarpower,couldbeusedasthe primarysupplytoDanfosssubstations.Forthesakeofsimplicity, DHcanbetakentomeantheprimarysupply.
Connections:
1.Districtheating(DH)supply
2.Districtheating(DH)return
3.Hotwatercirculation(HWC)
4.Domestichotwater(DHW)
5.Domesticcoldwater(DCW)
Authorizedpersonnelonly
Assembly,start-upandmaintenanceworkmustbeperformedby qualifiedandauthorizedpersonnelonly.
Type2–5
Connectionsizes:
DH+DCW+DHW: HWC:
Dimensions(mm):
Type2-5withoutcover: H660xW510xD240 Type2-5withcover: H800xW540xD360
Type6-8withoutcover: H920xW720xD385 Type6-8withcover: H920xW800xD450
Weight(approx.):20–40kg
G1”(int.thread) G¾”(int.thread)
Type6–8
Thepipeplacementcandeviatefromtheshowndrawing.Pleasenote themarkingsonthestation.
VI.EH.C5.02/LUK41500
©Danfoss|2019.01|5
Page 6
OperatingGuideTermixBV
4.1.1Installation
Mounting:
Adequatespace
Pleaseallowadequatespacearoundthesubstationformounting andmaintenancepurposes.
Orientation
Thestationmustbemountedsothatcomponents,keyholes andlabelsareplacedcorrectly.Ifyouwishtomountthestation differentlypleasecontactyoursupplier.
Drillings
Wheresubstationsaretobewall-mounted,drillingsareprovided inthebackmountingplate.Floormountedunitshavesupport.
Labelling
Eachconnectiononthesubstationislabelled.
Beforeinstallation:
Cleanandrinse
Priortoinstallation,allsubstationpipesandconnectionsshouldbe cleanedandrinsed.
Keyholeformounting.
Tightening
Duetovibrationduringtransport,allsubstationconnectionsmust becheckedandtightenedbeforeinstallation.
Unusedconnections
Unusedconnectionsandshut-offvalvesmustbesealedwitha plug.Shouldtheplugsrequireremoval,thismustonlybedoneby anauthorizedservicetechnician.
Installation:
Strainer
Ifastrainerissuppliedwiththestationitmustbefittedaccording toschematicdiagram.Pleasenotethatthestrainermaybe suppliedloose.
Connections
Internalinstallationanddistrictheatingpipesconnectionsmustbe madeusingthreaded,flangedorweldedconnections.
6|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 7
OperatingGuideTermixBV

4.2Electricalconnections

Beforemakingelectricalconnections,pleasenotethe following:
Safetynotes
Pleasereadtherelevantpartsofthesafetynotes.
230V
Thesubstationmustbeconnectedto230VACandearth.
Potentialbonding
Potentialbondingshouldbecarriedoutaccording to60364-4-41:2007andIEC60364-5-54:2011. Bondingpointonthemountingplatebelowrightcornermarked withearthsymbol.
Disconnection
Thesubstationmustbeelectricallyconnectedsothatitcanbe disconnectedforrepairs.
Outdoortemperaturesensor
Outdoorsensorsshouldbemountedsoastoavoidexposureto directsunlight.Theyshouldnotbeplacedclosetodoors,windows orventilationoutlets.
Theoutdoorsensormustbeconnectedtothestationonthe terminalblockundertheelectroniccontrol.
Authorizedelectrician
Electricalconnectionsmustbemadebyanauthorizedelectricianonly.
Localstandards
Electricalconnectionsmustbemadeinaccordancewithcurrent regulationsandlocalstandards.
VI.EH.C5.02/LUK41500
©Danfoss|2019.01|7
Page 8
OperatingGuideTermixBV

5.0Design

5.1Design

Yoursubstationmightlookdifferentthanthesubstationshown.
Designdescription
B
Heatexchanger,DHW
2
Singlecheckvalve
7
Thermostaticcontroller,DHW
11
Domestichotwaterpump
18
Thermometer
8|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 9
OperatingGuideTermixBV

5.2Schematicdiagram

Schematicdiagramtype2-5(example)
DH
Supply
DH
Return
Yoursubstationmightlookdifferentthantheschematicdiagramshown.
Schematicdescription
B
Heatexchanger,DHW
2
Singlecheckvalve
7
Thermostaticvalve
DHW:DomesticHotWater DCW: HWC: DHSupply:DistrictHeatingSupply DHReturn:DistrictHeatingReturn
DomesticColdWater HotWaterCirculation
11
Domestichotwaterpump
18
Thermometer
DHW
DCW
HWC
5.2.1Technicalparameters
Technicalparameters
Nominalpressure: Max.DHsupplytemperature: Min.DCWstaticpressure: Brazingmaterial(HEX): Heatexchangerstestpressure:30bar Soundlevel:≤55dB
VI.EH.C5.02/LUK41500
PN16 120°C
0.5bar Copper
©Danfoss|2019.01|9
Page 10
OperatingGuideTermixBV

5.3Design

Yoursubstationmightlookdifferentthanthesubstationshown.
Designdescription
B
Heatexchanger,DHW
G
Electroniccontroller,DHW
2
Singlecheckvalve
11
Domestichotwaterpump
18
Thermometer
27
Actuator
30
Flowcontrolwithcontrolvalve
10|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 11
OperatingGuideTermixBV

5.4Schematicdiagram

Schematicdiagramtype2-8withelectroniccontroller(example)
DH
Supply
DH
Return
Yoursubstationmightlookdifferentthantheschematicdiagramshown.
Schematicdescription
B
Heatexchanger,DHW
G
Electroniccontroller,DHW
2
Singlecheckvalve
11
Domestichotwaterpump
DHW:DomesticHotWater DCW: HWC: DHSupply:DistrictHeatingSupply DHReturn:DistrictHeatingReturn
DomesticColdWater HotWaterCirculation
18
Thermometer
19
Surfacesensor
27
Actuator
30
Flowcontrolwithcontrolvalve
40
Immersionsensor
DHW
DCW
HWC
5.4.1Technicalparameters
Technicalparameters
Nominalpressure: Max.DHsupplytemperature: Min.DCWstaticpressure: Brazingmaterial(HEX): Heatexchangerstestpressure:30bar Soundlevel:≤55dB
VI.EH.C5.02/LUK41500
PN16 120°C
0.5bar Copper
©Danfoss|2019.01|11
Page 12
OperatingGuideTermixBV

6.0Controls

6.1DHWtemperaturecontrol

DHWtemperaturecontrol
TherearevarioustypesofDHWtemperaturecontrolusedin Danfosssubstations. DHWtemperatureshouldbeadjustedto45-50°C,asthisprovides optimalutilisationofDHwater.AtDHWtemperaturesabove55°C, thepossibilityoflimescaledepositsincreasessignificantly.
Twovalvesincascade
Iftwothermostaticcontrolvalvesaremountedparallelincascade, itisimportanttoadjustthevalvesaccordingtothefollowing:The smallvalveisforcontrollingsmalltappingflowsandthelargevalve isforcontrollinglargetappingflows.
1.Thelargevalveisclosedcompletely(thehandleisturnedall thewaytothetop).
2.Onetapisopened.
3.Thesmallvalveissetatthedesiredtemperature(50°C).Theset pointismarkedandthevalveisclosedcompletely.
4.Severaltapsareopenedandthelargevalveisset3-5°Clower thanthesmallvalve.
5.Thehandleofthesmallvalveisturnedbacktothemarked point.
Pleasenote
Itisimportantthatthesmallvalveisset3-5°Chigherthanthe largevalve;otherwiseitisnotpossibletocontrolthetemperature ofsmalltappingflowscorrectly.
6.1.1AVTBcontroller(20–60°)
Thetemperaturesettingisasfollows: 1=20°C 2=35°C 3=50°C 4=60°C 5=70°C
Thevaluesareintendedasaguide.
TheAVTBoperatesatitsbestatDHsupplytemperaturesofupto 90°C.
Thermostaticcontrol
DHWtemperatureisadjustedasfollows: Toincreasetemperature,turnthehandleonthethermostatic controllertoselectahighernumber. Todecreasetemperature,turnthehandleonthethermostatic controllertoselectalowernumber.
12|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 13
OperatingGuideTermixBV
6.1.2Electroniccontrol
Substationswithelectroniccontrolmustbesetinaccordancewith manufacturer´sinstructions. Wheretheroomtemperatureiscontrolledbyradiatorthermostats, itisrecommendedthatthermostatsbesetforminimum temperatureineachroom.
6.1.3Flowcontrollerwithintegratedcontrolvalve
Thecontrollerisaself-actingflowcontrollerwithintegratedcontrol valve.Thecontrollercloseswhensetmax.flowisexceededand canbeusedincombinationwithDanfosselectricalactuatorswith orwithoutsafetyfunction.Springreturnmotorcanbeusedas safetyfunctionbypowerfailure.
6.1.4Electric2–waymotorizedvalve
Actuatorswithorwithoutsafetyfunctionareavailablefor3-point controls.Spring-returnactuatorscanbeusedtoprovidesafety shut-offintheeventofpowerfailure.
VI.EH.C5.02/LUK41500
©Danfoss|2019.01|13
Page 14
OperatingGuideTermixBV
6.1.5Domestichotwaterpump
Important!
Itisnecessarytomountadomestichotwatercirculationpumpon thewaterheatertoavoidregulationproblems. Thecirculationpumpcannotbeswitchedoff,sincethiswillresult inregulationproblems.(noflowatthesensor).
14|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 15
OperatingGuideTermixBV

6.2Other

6.2.1Safetyvalve
Thepurposeofthesafetyvalveistoprotectthesubstationfrom excessivepressure. Theblow-offpipefromthesafetyvalvemustnotbeclosed.The blow-offpipeoutletshouldbeplacedsothatitdischargesfreely anditispossibletoobserveanydrippingfromthesafetyvalve. Itisrecommendedtochecktheoperationofsafetyvalvesat intervalsof6months.Thisisdonebyturningthevalveheadin directionindicated.
VI.EH.C5.02/LUK41500
©Danfoss|2019.01|15
Page 16
OperatingGuideTermixBV

6.3Maintenance

Thesubstationrequireslittlemonitoring,apartfromroutine checks.Itisrecommendedtoreadtheenergymeteratregular intervals,andtowritedownthemeterreadings.
RegularinspectionsofthesubstationaccordingtothisInstruction arerecommended,whichshouldinclude:
Strainers
Cleaningofstrainers.
Meters
Checkingofalloperatingparameterssuchasmeterreadings.
Temperatures
Checkingofalltemperatures,suchasDHsupplytemperatureand DHWtemperature.
Connections
Checkingallconnectionsforleakages.
Safetyvalves
Theoperationofthesafetyvalvesshouldbecheckedbyturning thevalveheadintheindicateddirection.
Venting
Checkingthatthesystemisthoroughlyvented.
Authorizedpersonnelonly
Assembly,start-upandmaintenanceworkmustbeperformedby qualifiedandauthorizedpersonnelonly.
Inspectionsshouldbecarriedoutminimumeverytwoyears.
SparepartscanbeorderedfromDanfoss.Pleaseensurethatany enquiryincludesthesubstationserialnumber.
16|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 17
OperatingGuideTermixBV

7.0Troubleshooting

7.1Troubleshootingingeneral

Intheeventofoperatingdisturbances,thefollowingbasicfeatures shouldbecheckedbeforecarryingoutactualtroubleshooting:
thesubstationisconnectedtoelectricity,
thestrainerontheDHsupplypipeisclean,
thesupplytemperatureoftheDHisatthenormallevel (summer,atleast60°C-winter,atleast70°C),
thedifferentialpressureisequaltoorhigherthanthenormal (local)differentialpressureintheDHnetwork–ifindoubt,ask theDHplantsupervisor,
pressureonthesystem-checktheHEpressuregauge.
Authorizedpersonnelonly
Assembly,start-upandmaintenanceworkmustbeperformedby qualifiedandauthorizedpersonnelonly.
VI.EH.C5.02/LUK41500
©Danfoss|2019.01|17
Page 18
OperatingGuideTermixBV

7.2TroubleshootingDHW

ProblemPossiblecauseSolution
ToolittleornoDHW.
Taptemperaturetoohigh;DHWtapload toohigh.
Temperaturedropduringtapping.
Thermostaticcontrolvalvedoesnotclose
Strainerinsupplyorreturnlineclogged.Cleanstrainer(s).
DHWcirculationpumpoutoforderorwith toolowsetting.
Defectiveorcloggednon-returnvalve.
Noelectricity.Check.
Wrongsettingofautomaticcontrols,ifany.Toadjustanelectroniccontrollerfor
Scalingoftheplateheatexchanger.
Defectivemotorizedvalve.Check(usemanualfunction)–replace.
Defectivetemperaturesensors.
Defectivecontroller.
DCWisbeingmixedwiththeDHW,e.g.ina defectivethermostaticmixingvalve.
Defectiveorcloggednon-returnvalveon circulationvalve.
Thermostaticvalveadjustedtoatoohigh level.
Scalingoftheplateheatexchanger.
LargerDHWflowthanthesubstationhas beendesignedfor.
TemperaturedifferencebetweenDH supplyandDHWsetpointtoolow.
Checkcirculationpump.
Replace–clean.
DHW,pls.noteenclosedinstructionsfor electroniccontroller.
Replace–rinseout.
Check–replace.
Check–replace.
Check–replace. Hotwaterinsometapsbutnotinall.
Replace–clean.
Check–set.
Replace–rinseout.
ReduceDHWflow.
Lowerthesetpointtemperatureorincrease theDHsupplytemperature.
18|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 19
OperatingGuideTermixBV

7.3Disposal

Disposal
Thisproductshouldbedismantledanditscomponents sorted,ifpossible,invariousgroupsbeforerecycling ordisposal.
Alwaysfollowthelocaldisposalregulations.
VI.EH.C5.02/LUK41500
©Danfoss|2019.01|19
Page 20
OperatingGuideTermixBV
20|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 21
OperatingGuideTermixBV
21|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 22
OperatingGuideTermixBV
22|©Danfoss|2019.01
VI.EH.C5.02/LUK41500
Page 23
OperatingGuideTermixBV

8.0Declaration

8.1Declarationofconformity

Category0withelectricalequipment
VI.EH.C5.02/LUK41500
©Danfoss|2019.01|23
Page 24
OperatingGuideTermixBV
24|©Danfoss|2019.01
VI.EH.C5.02/LUK41500