This is a compensated spreader valve with dual ow
regulation and manual dump for an open circuit gear
pump application. This is a direct replacement to the
2FFL12.
APPLICATIONS
The valve maintains constant regulated ow to two
actuators even with changes in load pressure or
input ow. The pressure-compensated regulating
section bypasses excess pump ow to tank. The pump
operates at the highest load pressure plus control
section pressure drop. The tank or bypass port must be
referenced directly to tank and not to a working line.
The direct-acting relief valve senses system pressure
and protects the pump from shock or overload pressure
surges. The built-in lever-operated two-way valve
dumps system ow to tank, allowing on/o control
of both regulated ows without changing either ow
setting. In the unload condition, an 8.6 bar [125 psi]
check valve may be required in either the A port, the S
port or both ports to reduce motor movement potential.
SCHEMATIC
SPECIFICATIONS
Rated Pressure138 bar [2000 psi]
Maximum Rated Flow at 7 bar
[100 psi]
Weight 2.62 kg [5.90 lb]
114 l/m
[30 US gal/min]
PERFORMANCE CURVE
BC332376275117en-000101 • February 2020
SP - 2
DIMENSIONS
mm [in]
Spreader Valves Technical Information
SPR-2FFL12
EXAMPLE CIRCUIT
ORDERING INFORMATION
SPR-2FFL12 -
Adjustment Option
Code
Adjustment
D
Detented hand knob
Port Size
Code Port P and T Port A Port S
12S 12 SAE 10 SAE 8 SAE
Kits
Knob Kit
Seal Kit (for 2 adjust assemblies)
Lever Kit
BC332376275117en-000101 • February 2020
158B8962
158B8858
158B8972
Relief Valve: CP200-1
D
-
12S
-
V
-
7/15
Regulated Flow Range
Code
7/15
10/30
Seal Option
Code Seal Material
V Viton
S (Spinner)
7 = 0 - 26 LPM (0-7 GPM)
10 = 0 - 38 LPM (0-10 GPM)
A (Auger)
15 = 0 - 57 LPM (0-15 GPM)
30 = 0 - 114 LPM (0-30 GPM)
SP - 3
Spreader Valves Technical Information
SPR-2FFLC12
OPERATION
This is a compensated spreader valve with dual ow
regulation and manual dump for an open circuit piston
pump application. This is a direct replacement to the
2FFLC12
APPLICATIONS
For use with variable displacement pressure
compensated pumps in load sensing circuits that
require two pressure compensated ow controls. The
integral lever allows on/o pump control. This valve is
designed for speed control of two actuators which must
have individual ow settings. The LS port senses the
load pressure on both actuators to signal the pump to
increase or decrease the supply ow. With the lever in
the unload position, no load is sensed and the pump
de-strokes.
SPECIFICATIONS
Rated Pressure207 bar [3000 psi]
Maximum Rated Flow at 7 bar
[100 psi]
Weight3.08 kg [6.79 lb]
114 l/m
[30 US gal/min]
PERFORMANCE CURVE
SCHEMATIC
BC332376275117en-000101 • February 2020
SP - 4
SPR-2FFLC12 - D - 12S - 7/15 -
V
DIMENSIONS
mm [in]
Spreader Valves Technical Information
SPR-2FFLC12
EXAMPLE CIRCUIT
ORDERING INFORMATION
Port Size
Code Port P Port A Port S Port T Port LS
12S 12 SAE 10 SAE 8 SAE 6 SAE 4 SAE
Kits
Knob Kit
Seal Kit (for 2 adjust assemblies)
Lever Kit
Adjustment Option
Code
Adjustment
D
Detented hand knob
158B8962
158B8858
11109844
Seal Option
Code Seal Material
V Viton
Regulated Flow Range
Code
S (Spinner)
7/15
7 = 0 - 26 LPM (0-7 GPM)
A (Auger)
15 = 0 - 57 LPM (0-15 GPM)
BC332376275117en-000101 • February 2020
SP - 5
Spreader Valves Technical Information
SPR-2FFLW86
OPERATION
This is a compensated spreader valve with dual ow
regulation and solenoid dump for an open circuit gear
pump application. This is a direct replacement to the
2FFLW86.
APPLICATIONS
For use with xed displacement pumps in circuits that
require two pressure compensated ow controls, solenoid
valve for on-o dump and pump relief. The valve maintains
constant regulated ow to two actuators even with changes
in load pressure or input ow. The pressure-compensated
regulating section bypasses excess pump ow to tank. The
pump operates at the highest load pressure plus control
section pressure drop. The tank or bypass port must be
referenced directly to tank and not to a working line. The
direct acting relief valve senses system pressure and protects
the pump from shock or overload pressure surges. The
built-in, solenoid-operated, two-way valve unloads system
ow to tank. This allows on-o control of both regulated
ows without changing either ow setting. In the unload
condition an 8.6 bar [125 psi] check valve may be required
in either the A port, the S port or both ports to reduce the
potential of motor movement.
SPECIFICATIONS
Rated Pressure138 bar [2000 psi]
Maximum Rated Flow at 7 bar
[100 psi]
Weight including coil3.08 kg [6.79 lbs]
Robust CoilR13 16 Watt (“FL” Connector)
114 l/m
[30 US gal/min]
Robust Nut P/N 173800539
(no coil O-rings needed)
SCHEMATIC
PERFORMANCE CURVE
BC332376275117en-000101 • February 2020
SP - 6
DIMENSIONS
SPR-2FFLW86 - D - 12S - 7/15 - V
Adjustment Option
Seal Option
Code Seal Material
V Viton
Regulated Flow Range
Kits
Port Size
Code Port P Port A Port S
12S 12 SAE 10 SAE 8 SAE
Relief Valve: CP200-1
Solenoid Valve: SVP08-NO
Code
D
Adjustment
Detented hand knob
Code
7/15
10/30
S (Spinner)
7 = 0 - 26 LPM (0-7 GPM)
10 = 0 - 38 LPM (0-10 GPM)
A (Auger)
15 = 0 - 57 LPM (0-15 GPM)
30 = 0 - 114 LPM (0-30 GPM)
Knob Kit
Seal Kit (for 2 adjust assemblies)
158B8962
158B8858
mm [in]
Spreader Valves Technical Information
SPR-2FFLW86
EXAMPLE CIRCUIT
ORDERING INFORMATION
BC332376275117en-000101 • February 2020
SP - 7
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.