Danfoss Spreader Valves Technical Information

Spreader Valves Technical Information
Quick Reference
SCHEMATIC MODEL PRESSURE FLOW* WEIGHT
Page 2Page 4
Spreader Valve, Dual Flow Regulation,
Compensated, Manual Dump, Gear Pump
Circuit
Spreader Valve, Dual Flow Regulation,
Compensated, Manual Dump, Piston
Pump Circuit
Page 6
SPR-2FFL12
SPR-2FFLC12
SPR-2FFLW86
[2000 psi]
[3000 psi]
[2000 psi]
114 l/m
[30 US g/m]
114 l/m
[30 US g/m]
114 l/m
[30 US g/m]
2.62 kg
[5.90 lb]
3.08 kg
[6.79 lb]
3.08 kg
[6.79 lb]
Spreader Valve, Dual Flow Regulation,
Compensated, Solenoid Dump, Gear
Pump Circuit
BC332376275117en-000101 • February 2020
SP - 1
Spreader Valves Technical Information
SPR-2FFL12
OPERATION
This is a compensated spreader valve with dual ow regulation and manual dump for an open circuit gear pump application. This is a direct replacement to the 2FFL12.
APPLICATIONS
The valve maintains constant regulated ow to two actuators even with changes in load pressure or input ow. The pressure-compensated regulating section bypasses excess pump ow to tank. The pump operates at the highest load pressure plus control section pressure drop. The tank or bypass port must be referenced directly to tank and not to a working line. The direct-acting relief valve senses system pressure and protects the pump from shock or overload pressure surges. The built-in lever-operated two-way valve dumps system ow to tank, allowing on/o control of both regulated ows without changing either ow setting. In the unload condition, an 8.6 bar [125 psi] check valve may be required in either the A port, the S port or both ports to reduce motor movement potential.
SCHEMATIC
SPECIFICATIONS
Rated Pressure 138 bar [2000 psi] Maximum Rated Flow at 7 bar [100 psi] Weight 2.62 kg [5.90 lb]
114 l/m [30 US gal/min]
PERFORMANCE CURVE
BC332376275117en-000101 • February 2020
SP - 2
DIMENSIONS
mm [in]
Spreader Valves Technical Information
SPR-2FFL12
EXAMPLE CIRCUIT
ORDERING INFORMATION
SPR-2FFL12 -
Adjustment Option
Code
Adjustment
D
Detented hand knob
Port Size
Code Port P and T Port A Port S
12S 12 SAE 10 SAE 8 SAE
Kits
Knob Kit
Seal Kit (for 2 adjust assemblies)
Lever Kit
BC332376275117en-000101 • February 2020
158B8962
158B8858
158B8972
Relief Valve: CP200-1
D
-
12S
-
V
-
7/15
Regulated Flow Range
Code
7/15
10/30
Seal Option
Code Seal Material
V Viton
S (Spinner)
7 = 0 - 26 LPM (0-7 GPM)
10 = 0 - 38 LPM (0-10 GPM)
A (Auger)
15 = 0 - 57 LPM (0-15 GPM)
30 = 0 - 114 LPM (0-30 GPM)
SP - 3
Spreader Valves Technical Information
SPR-2FFLC12
OPERATION
This is a compensated spreader valve with dual ow regulation and manual dump for an open circuit piston pump application. This is a direct replacement to the 2FFLC12
APPLICATIONS
For use with variable displacement pressure compensated pumps in load sensing circuits that require two pressure compensated ow controls. The integral lever allows on/o pump control. This valve is designed for speed control of two actuators which must have individual ow settings. The LS port senses the load pressure on both actuators to signal the pump to increase or decrease the supply ow. With the lever in the unload position, no load is sensed and the pump de-strokes.
SPECIFICATIONS
Rated Pressure 207 bar [3000 psi] Maximum Rated Flow at 7 bar [100 psi] Weight 3.08 kg [6.79 lb]
114 l/m [30 US gal/min]
PERFORMANCE CURVE
SCHEMATIC
BC332376275117en-000101 • February 2020
SP - 4
SPR-2FFLC12 - D - 12S - 7/15 -
V
DIMENSIONS
mm [in]
Spreader Valves Technical Information
SPR-2FFLC12
EXAMPLE CIRCUIT
ORDERING INFORMATION
Port Size
Code Port P Port A Port S Port T Port LS
12S 12 SAE 10 SAE 8 SAE 6 SAE 4 SAE
Kits
Knob Kit
Seal Kit (for 2 adjust assemblies)
Lever Kit
Adjustment Option Code
Adjustment
D
Detented hand knob
158B8962
158B8858
11109844
Seal Option
Code Seal Material
V Viton
Regulated Flow Range
Code
S (Spinner)
7/15
7 = 0 - 26 LPM (0-7 GPM)
A (Auger)
15 = 0 - 57 LPM (0-15 GPM)
BC332376275117en-000101 • February 2020
SP - 5
Spreader Valves Technical Information
SPR-2FFLW86
OPERATION
This is a compensated spreader valve with dual ow regulation and solenoid dump for an open circuit gear pump application. This is a direct replacement to the 2FFLW86.
APPLICATIONS
For use with xed displacement pumps in circuits that require two pressure compensated ow controls, solenoid valve for on-o dump and pump relief. The valve maintains constant regulated ow to two actuators even with changes in load pressure or input ow. The pressure-compensated regulating section bypasses excess pump ow to tank. The pump operates at the highest load pressure plus control section pressure drop. The tank or bypass port must be referenced directly to tank and not to a working line. The direct acting relief valve senses system pressure and protects the pump from shock or overload pressure surges. The built-in, solenoid-operated, two-way valve unloads system ow to tank. This allows on-o control of both regulated ows without changing either ow setting. In the unload condition an 8.6 bar [125 psi] check valve may be required in either the A port, the S port or both ports to reduce the potential of motor movement.
SPECIFICATIONS
Rated Pressure 138 bar [2000 psi] Maximum Rated Flow at 7 bar [100 psi] Weight including coil 3.08 kg [6.79 lbs]
Robust Coil R13 16 Watt (“FL” Connector)
114 l/m [30 US gal/min]
Robust Nut P/N 173800539 (no coil O-rings needed)
SCHEMATIC
PERFORMANCE CURVE
BC332376275117en-000101 • February 2020
SP - 6
DIMENSIONS
SPR-2FFLW86 - D - 12S - 7/15 - V
Adjustment Option
Seal Option
Code Seal Material
V Viton
Regulated Flow Range
Kits
Port Size
Code Port P Port A Port S
12S 12 SAE 10 SAE 8 SAE
Relief Valve: CP200-1
Solenoid Valve: SVP08-NO
Code
D
Adjustment
Detented hand knob
Code
7/15
10/30
S (Spinner)
7 = 0 - 26 LPM (0-7 GPM)
10 = 0 - 38 LPM (0-10 GPM)
A (Auger)
15 = 0 - 57 LPM (0-15 GPM)
30 = 0 - 114 LPM (0-30 GPM)
Knob Kit
Seal Kit (for 2 adjust assemblies)
158B8962
158B8858
mm [in]
Spreader Valves Technical Information
SPR-2FFLW86
EXAMPLE CIRCUIT
ORDERING INFORMATION
BC332376275117en-000101 • February 2020
SP - 7