Danfoss SC21G Data sheet

Datasheet
SC21G Universal Compressor
R134a 220-240V 50/60Hz
General
Code number 104G8140
Approvals EN 60335-2-34
Compressors on pallet 80
Application LBP/HBP LBP
Frequency Hz 50 60
Evaporating temperature °C -25 to 15 -25 to -5
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C F2F2F2F2–
38°C F
43°C F
Remarks on application:
Not applicable below -25°C evaporating temp. in 43°C ambient temperature above 240V.
HBP at 198 - 254V 50Hz only.
Motor
Motor type CSR
LRA (rated after 4 sec. UL984), HST | LST A 21.8
Cut in Current, HST | LST A 21.8
Resistance, main | start winding (25°C) 3.5 12.1
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 1300
Free gas volume in compressor cm
Weight without electrical equipment kg 13.5
Dimensions
Height mm A 219
Suction connector location/I.D. mm | angle C 10.2 | 37°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 6.2 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
2F2F2F2
2F2F2F2
3
3
3
550 (polyolester)
B 213
B1 193
B2 110
20.95
1460
S =Staticcoolingnormallysufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
= not applicable in this area
DEHC.ED.400.M7.02 / 521X0847 | 12014.11 Manufactured by Secop for Danfoss
EN 12900 Household 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 333 370 453 606 792 934 1012 1268 1560 1700 1889 2256
Power cons. in W 382 404 445 509 575 620 643 714 789 823 868 953
Current cons. in A 2.28 2.34 2.48 2.71 2.96 3.14 3.24 3.54 3.87 4.02 4.22 4.60
COP in W/W 0.87 0.92 1.02 1.19 1.38 1.51 1.58 1.78 1.98 2.07 2.18 2.37
ASHRAE LBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 410 456 558 746 977 1156 1250 1568 1931 2106 2343 2803
Power cons. in W 382 404 445 509 575 620 643 714 789 823 868 953
Current cons. in A 2.28 2.34 2.48 2.71 2.96 3.14 3.24 3.54 3.87 4.02 4.22 4.60
COP in W/W 1.07 1.13 1.25 1.47 1.70 1.86 1.95 2.20 2.45 2.56 2.70 2.94
EN 12900 Household 230V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 311 364 476 671 903 1078 1175
Power cons. in W 374 406 466 553 638 693 721
Current cons. in A 1.82 1.95 2.21 2.58 2.95 3.19 3.31
COP in W/W 0.83 0.90 1.02 1.21 1.42 1.56 1.63
ASHRAE LBP 230V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 392 457 595 835 1121 1336 1456
Power cons. in W 378 409 468 554 637 692 720
Current cons. in A 1.83 1.96 2.21 2.58 2.94 3.18 3.29
COP in W/W 1.04 1.12 1.27 1.51 1.76 1.93 2.02
Accessories for SC21G Figure Code number Test conditions
Sarting device
550 mm cable length 117-7029 Ambient temperature 32°C 32°C
a3
Condensing temperature 55°C 55°C
EN 12900/CECOMAF
ASHRAE LBP
650 mm cable length 117-7032 Suction gas temperature 32°C 32°C
Cover b 103N2009 Liquid temperature no subcooling 32°C
Starting relay a2
Starting capacitor c Mounting accessories Code number
Run capacitor e Bolt joint for one comp. Ø: 16 mm 118-1917
Components
of starting
device
Cord relief d 103N1004 Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
DEHC.ED.400.M7.02 / 521X0847 | 22014.11 Manufactured by Secop for Danfoss