Danfoss SC18MNX MBP Data sheet

SC18MNX MBP Compressor R290 220-240V 50Hz
General
Code number 104H8875
Approvals EN 60335-2-34,CCC
Application
Application MBP
Frequency Hz 50 60
Evaporating temperature °C -25 to 10
Voltage range V 198 - 254
Max. condensing temperature continuous (short) °C 55 (65)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C F2–
38°C F
43°C F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 23.4
Cut in Current, HST | LST A 23.6
Resistance, main | start winding (25°C) 3.4 14.4
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 150
Free gas volume in compressor cm
Weight without electrical equipment kg 14.0
Dimensions
Height mm A 219
Suction connector location/I.D. mm | angle C 8.2 | 37°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 6.2 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
2
2
3
3
3
B 213
B1 193
B2 110
17.69
600 (polyolester)
1460
S = Static cooling normally sufcient O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
May 2013 Manufactured by Secop for Danfoss - DEHC.ED.540.D6.02 / 520N1463 1/2
EN 12900 MBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 675 730 844 1039 1263 1428 1519 1810 2140 2298 2512
Power cons. in W 544 567 608 662 709 736 749 785 818 833 851
Current cons. in A 3.91 3.96 4.06 4.22 4.38 4.49 4.54 4.71 4.87 4.95 5.04
COP in W/W 1.24 1.29 1.39 1.57 1.78 1.94 2.03 2.31 2.61 2.76 2.95
EN 12900 Household 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 569 618 719 891 1088 1232 1312 1567 1857 1996 2184
Power cons. in W 547 578 634 709 774 813 831 882 927 946 970
Current cons. in A 3.96 4.03 4.17 4.38 4.60 4.75 4.82 5.05 5.27 5.37 5.50
COP in W/W 1.28 1.32 1.40 1.55 1.74 1.88 1.95 2.20 2.49 2.62 2.80
ASHRAE HBP/MBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 625 679 790 979 1195 1355 1442 1724 2044 2198 2406
Power cons. in W 547 578 633 707 771 808 826 876 921 939 962
Current cons. in A 3.95 4.02 4.16 4.37 4.59 4.73 4.81 5.03 5.25 5.35 5.48
COP in W/W 1.14 1.18 1.25 1.39 1.55 1.68 1.75 1.97 2.22 2.34 2.50
Accessories for SC18MNX Figure Code
number
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors Ambient temperature 32°C 32°C 35°C
Condensing temp. 45°C 55°C 54.4°C
Test conditions
EN 12900
MBP Household
ASHRAE
HBP/MBP
Starting relay 6.3 mm spade connectors a2 117U7011 Suction gas temp. 20°C 32°C 35°C
Cover b 103N2008 Liquid temperature no subcooling 46.1°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5017
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.540.D6.02 / 520N1463 May 2013
Loading...