SC18CNX
LBP/MBP Compressor
R290
220-240V 50Hz
General
Code number 104H8867
Approvals EN 60335-2-34
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °C -40 to 5 –
Voltage range V 198 - 254 –
Max. condensing temperature continuous (short) °C 55 (65) –
Max. winding temperature continuous (short) °C 125 (135) –
Cooling requirements
Frequency Hz 50 60
Application
32°C F2F2– – – –
38°C F
43°C F
Remarks on application:
Motor
Motor type CSR
LRA (rated after 4 sec. UL984), HST | LST A 19.5 –
Cut in Current, HST | LST A 19.5 –
Resistance, main | start winding (25°C) Ω 4.6 17.8
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 150
Free gas volume in compressor cm
Weight without electrical equipment kg 13.5
Dimensions
Height mm A 209
Suction connector location/I.D. mm | angle C 9.7 | 37°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.5 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 6.5 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
2F2
2F2
3
3
3
B 203
B1 183
B2 100
– – – –
– – – –
17.69
600 (polyolester)
1460
S = Static cooling normally sufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
February 2012 Manufactured by Secop for Danfoss - DEHC.ED.540.E3.02 / 520N1306 1/2
EN 12900 Household (CECOMAF)* 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 219 341 480 640 700 824 1033 1272 1448 1543 1849 2193
Power cons. in W 304 370 435 500 522 566 635 707 756 783 864 952
Current cons. in A 1.80 2.08 2.34 2.60 2.68 2.85 3.09 3.32 3.47 3.54 3.76 3.97
COP in W/W 0.72 0.92 1.10 1.28 1.34 1.45 1.63 1.80 1.91 1.97 2.14 2.30
ASHRAE LBP* 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 244 380 535 714 781 919 1154 1422 1618 1726 2070 2456
Power cons. in W 304 370 435 500 522 566 635 707 756 783 864 952
Current cons. in A 1.80 2.08 2.34 2.60 2.68 2.85 3.09 3.32 3.47 3.54 3.76 3.97
COP in W/W 0.80 1.03 1.23 1.43 1.49 1.62 1.82 2.01 2.14 2.20 2.39 2.58
Accessories for SC18CNX Figure Code number Test conditions
EN 12900/
ASHRAE LBP*
CECOMAF*
Starting device
470 mm cable length
a3
(pos.1)
117-7034
Condensing temperature 45°C 45°C
Ambient temperature 32°C 32°C
Starting device (kit) 1020 mm cable length (pos.2) 117-9718 Suction gas temperature 32°C 32°C
Starting relay a2
Start. capacitor c
Run capacitor e Mounting accessories Code number
Components of
starting device
Liquid temperature no subcooling 32°C
Cover b 103N2009 Bolt joint for one comp. Ø: 16 mm 118-1917
Cord relief d 103N1004 Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.540.E3.02 / 520N1306 February 2012