Danfoss SC18, SC18G Data sheet

SC18/18G Universal Twin Compressor R134a 220-240V 50Hz
General
Code number 104G8880
Approvals EN 60335-2-34, CCC
Application
Application LBP/HBP
Frequency Hz 50 60
Evaporating temperature °C -25 to 15
Voltage range V 198 - 254
Max. condensing temperature continuous (short) °C 60 (70)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C F2F2F2–
38°C F
43°C F
Remarks on application:
LBP MBP HBP LBP MBP HBP
2F2F2
2F2F2
S =Staticcoolingnormallysufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984) *, HST | LST A 2 x 18.6
Cut in Current *, HST | LST A 2 x 18.6
Resistance, main | start winding (25°C) 3.7 14.1
* Operational current for the second compressor time-delayed.
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 2200
Free gas volume in compressor cm
Weight without electrical equipment kg 28.0
Dimensions
Height mm A 259
Suction connector (service valve) location/I.D. mm C 16 | 37°
Suction connector (solder connector) location/I.D. mm C 16 | 37°
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 6.2 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09
Remarks:
3
3
3
1120 (polyolester)
B 254
B1 193
B2 110
2 x 17.69
2920
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.U4.02 / 520N1234 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 566 636 788 1052 1368 1344 1740 2174 2674 2918 3248 3900
Power cons. in W 662 702 778 896 1014 957 1136 1260 1390 1450 1526 1670
Current cons. in A 5.12 5.24 5.44 5.76 6.10 5.84 6.48 6.92 7.42 7.68 8.00 8.68
COP in W/W 0.86 0.91 1.01 1.18 1.35 1.40 1.53 1.72 1.92 2.01 2.13 2.34
ASHRAE LBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 696 784 970 1298 1688 1662 2148 2686 3310 3614 4028 4846
Power cons. in W 662 702 778 896 1014 957 1136 1260 1390 1450 1526 1670
Current cons. in A 5.12 5.24 5.44 5.76 6.10 5.84 6.48 6.92 7.42 7.68 8.00 8.68
COP in W/W 1.05 1.12 1.25 1.45 1.67 1.74 1.89 2.13 2.38 2.49 2.64 2.90
Accessories SC18/18G pcs. Code number Test conditions
EN 12900/
CECOMAF
ASHRAE
LBP
Starting device 470 mm cable length Condensing temperature 55°C 55°C
550 mm cable length 2 Ambient temperature 32°C 32°C
650 mm cable length Suction gas temperature 32°C 32°C
Starting relay 6.3 mm spade connectors 2 117U6019 Liquid temperature 55°C 32°C
Start. capacitor 80 µF 6.3 mm spade connectors 2 117U5017
Cover 2 103N2009
Cord relief 2 103N1004
Time-delay relay 1 117N0001
Check valve (to be used with time-delay relay) 2 020-1014
Service valve 12 mm 1
Solder connector (alternative) 12 mm 1
Service valve 16 mm 1 118-7351
Solder connector (alternative) 16 mm 1 118-7405
Seal ring for service valve and solder connector 1 118-3638
Mounting accessories pcs. Code number
Bolt joint for one compressor Ø: 16 mm 2 118-1917
Bolt joint in quantities Ø: 16 mm 2 118-1918
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.U4.02 / 520N1234 Dec 2011
Loading...