SC15MNX
MBP Compressor
R290
220-240V 50Hz
General
Code number 104H8575
Approvals EN 60335-2-34,CCC
Compressors on pallet 80
Application
Application MBP
Frequency Hz 50 60
Evaporating temperature °C -35 to 10 –
Voltage range V 198 - 254 –
Max. condensing temperature continuous (short) °C 55 (65) –
Max. winding temperature continuous (short) °C 125 (135) –
Cooling requirements
Frequency Hz 50 60
Application
32°C – F2– – – –
38°C – F
43°C – F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 18.6 –
Cut in Current, HST | LST A 18.6 –
Resistance, main | start winding (25°C) Ω 3.7 14.1
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 150
Free gas volume in compressor cm
Weight without electrical equipment kg 13.5
Dimensions
Height mm A 219
Suction connector location/I.D. mm | angle C 8.2 | 37°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 6.2 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
– – – –
2
– – – –
2
3
3
3
B 213
B1 193
B2 110
15.28
600 (polyolester)
1510
S = Static cooling normally sufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area
May 2013 Manufactured by Secop for Danfoss - DEHC.ED.540.C7.02 / 520N1462 1/2
EN 12900 MBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 313 428 561 611 715 893 1098 1249 1332 1598 1900 2044 2239
Power cons. in W 80 259 392 428 487 553 597 618 627 652 678 692 714
Current cons. in A 2.75 2.95 3.15 3.21 3.33 3.50 3.65 3.75 3.80 3.93 4.05 4.10 4.16
COP in W/W 3.89 1.65 1.43 1.43 1.47 1.62 1.84 2.02 2.12 2.45 2.80 2.95 3.13
ASHRAE HBP/MBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 329 440 564 610 705 866 1050 1185 1260 1499 1772 1901 2080
Power cons. in W 88 274 416 456 522 599 656 686 700 739 781 803 835
Current cons. in A 2.67 2.92 3.17 3.25 3.40 3.62 3.83 3.96 4.02 4.21 4.38 4.45 4.54
COP in W/W 3.75 1.60 1.35 1.34 1.35 1.44 1.60 1.73 1.80 2.03 2.27 2.37 2.49
Accessories for SC15MNX Figure Code number Test conditions
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors – Ambient temperature 32°C 35°C
–
– Condensing temperature 45°C 54.4°C
EN 12900
MBP
ASHRAE
HBP/MBP
Starting relay 6.3 mm spade connectors a2 117U7019 Suction gas temperature 20°C 35°C
Cover b 103N2008 Liquid temperature no subcooling 46.1°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5017
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC – – Bolt joint for one comp. Ø: 1 6 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.540.C7.02 / 520N1462 May 2013