SC15MLX.2
B
A
255
D
C
E
ø16
ø19
151
8257
107
115
55
63
37°
37°
107
55
170
178
204
165
186
70
150
35
101.6
127
127
B2
B1
63
3
ø9.7
218
MBP Compressor
R404A/R507
208-230V 60Hz
General
Code number 104L2803
Approvals UL984/CSA 22.2
Compressors on pallet 80
Application
Application MBP
Frequency Hz 50 60
Evaporating temperature °C – -23.3 to 7.2
Voltage range V – 187 - 254
Max. condensing temperature continuous (short) °C – 55 (60)
Max. winding temperature continuous (short) °C – 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C – – – – F2–
38°C – – – – F
43°C – – – – – –
Remarks on application:
Motor
Motor type CSR
LRA (rated after 4 sec. UL984), HST | LST A 30.0 –
Cut in Current, HST | LST A 30.0 –
Resistance, main | start winding (25°C) Ω 2.6 14.0
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 1300
Free gas volume in compressor cm
Weight without electrical equipment kg 14.0
Dimensions
Height mm A 219
Suction connector location/I.D. mm | angle C 9.7 | 37°
Process connector location/I.D. mm | angle D 6.5 | 37°
Discharge connector location/I.D. mm | angle E 6.5 | 37°
Oil cooler connector location/I.D. mm | angle F –
Connector tolerance I.D. mm ±0.09
Remarks:
material | comment Cu-plated steel | Al caps
material | comment Cu-plated steel | Al caps
material | comment Cu-plated steel | Al caps
material | comment –
LBP MBP HBP LBP MBP HBP
3
3
3
B 213
B1 193
B2 110
15.28
600 (polyolester)
1460
2
S = Static cooling normally sufficient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
–
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufficent
– = not applicable in this area
July 2009 DEHC.ED.400.N2.02 1/2
EN 12900 Household (CECOMAF) 230V, 60Hz, fan cooling F
M
11
22
N
N
L
L
5
4
2
1
b
d
Start winding
Main winding
Winding
protector
Thermostat
Fa n
e
a2
a2
Bleeder resistance
c
c
a3
e
a3
TO P
8227
CSR
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 784 915 1145 1418 1623 1737 2107 2531 2735
Power cons. in W 676 722 790 860 907 931 1004 1080 1114
Current cons. in A 3.09 3.27 3.56 3.88 4.09 4.21 4.55 4.92 5.09
COP in W/W 1.16 1.27 1.45 1.65 1.79 1.87 2.10 2.34 2.46
ASHRAE MBP 230V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 717 836 1049 1305 1500 1609 1965 2379 2581
Power cons. in W 703 757 838 920 975 1003 1087 1173 1212
Current cons. in A 3.22 3.43 3.76 4.11 4.35 4.48 4.87 5.28 5.47
COP in W/W 1.02 1.11 1.25 1.42 1.54 1.60 1.81 2.03 2.13
Accessories for SC15MLX.2 Figure Code number Test conditions EN 12900/CECOMAF ASHRAE MBP
Starting device
Condensing temperature 45°C 54.4°C
470 mm cable length 117-7058 Ambient temperature 32°C 35°C
a3
1000 mm cable length 117-7084 Suction gas temperature 32°C 35°C
Cover b 103N2008 Liquid temperature no subcooling 46.1°C
Starting relay a2
Start. capacitor 125 µF c Mounting accessories Code number
Run capacitor 15 µF e Bolt joint for one compressor Ø: 16 mm 118-1917
Cord relief d 103N1004 Bolt joint in quantities Ø: 16 mm 118-1918
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already
on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 DEHC.ED.400.N2.02 July 2009
Components
of starting
device
Snap-on in quantities Ø: 16 mm 118-1919