Danfoss SC15MLX.2 MBP Data sheet

Danfoss SC15MLX.2 MBP Data sheet

SC15MLX.2 MBP Compressor R404A/R507 208-230V 60Hz

General

Code number

 

 

 

 

104L2803

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approvals

 

 

 

UL984/CSA 22.2

 

 

 

 

 

 

 

 

 

 

 

 

Compressors on pallet

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

MBP

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Evaporating temperature

 

°C

 

 

 

-23.3 to 7.2

Voltage range

 

V

 

 

 

187 - 254

Max. condensing temperature continuous (short)

°C

 

 

 

 

55 (60)

 

Max. winding temperature continuous (short)

°C

 

 

 

125 (135)

Cooling requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Application

 

 

LBP

MBP

HBP

 

LBP

 

MBP

 

HBP

 

 

 

 

 

 

 

 

 

 

 

 

32°C

 

 

 

 

F2

 

38°C

 

 

 

 

F2

 

43°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remarks on application:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

 

CSR

 

 

 

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

30.0

 

 

 

 

 

Cut in Current, HST | LST

 

A

 

30.0

 

 

 

 

 

Resistance, main | start winding (25°C)

 

2.6

 

 

 

14.0

 

 

Design

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Displacement

 

cm3

 

 

15.28

 

 

 

 

Oil quantity (type)

 

cm3

 

600 (polyolester)

 

Maximum refrigerant charge

 

g

 

 

1300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Free gas volume in compressor

 

cm3

 

 

1460

 

 

 

 

Weight without electrical equipment

kg

 

 

14.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

 

mm

A

 

219

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

213

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B1

 

193

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B2

 

110

 

 

 

 

 

 

 

 

 

 

 

 

 

Suction connector

location/I.D. mm | angle

C

 

9.7 | 37°

 

 

 

 

 

 

 

 

 

 

material | comment

 

Cu-plated steel | Al caps

 

 

 

 

 

 

 

 

 

 

Process connector

location/I.D. mm | angle

D

 

6.5 | 37°

 

 

 

 

 

 

 

 

 

 

material | comment

 

Cu-plated steel | Al caps

 

 

 

 

 

 

 

 

 

 

Discharge connector

location/I.D. mm | angle

E

 

6.5 | 37°

 

 

 

 

 

 

 

 

 

 

material | comment

 

Cu-plated steel | Al caps

 

 

 

 

 

 

 

 

 

 

 

Oil cooler connector

location/I.D. mm | angle

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

material | comment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connector tolerance

 

I.D. mm

 

 

±0.09

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remarks:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

= Static cooling normally sufficient

O

= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

 

 

ø16

204

ø19

 

 

 

178

 

 

 

 

 

 

 

 

170

ø9.7

 

<![if ! IE]>

<![endif]>127

<![if ! IE]>

<![endif]>101.6

<![if ! IE]>

<![endif]>35

 

<![if ! IE]>

<![endif]>70

<![if ! IE]>

<![endif]>150

 

 

 

127

 

 

D

 

165

 

C

 

186

 

 

 

 

218

 

 

E

B1

 

 

 

B A

 

 

 

 

 

 

 

B2

 

<![if ! IE]>

<![endif]>3

 

 

 

 

 

 

255

 

 

<![if ! IE]>

<![endif]>151

37°

37°

<![if ! IE]>

<![endif]>63

 

<![if ! IE]>

<![endif]>55

<![if ! IE]>

<![endif]>55

<![if ! IE]>

<![endif]>63

 

 

107

107

8257

 

115

 

July 2009

DEHC.ED.400.N2.02

1/2

EN 12900 Household (CECOMAF)

230V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

-35

-30

-25

-23.3

-20

-15

-10

-6.7

-5

0

5

7.2

10

15

20

Capacity in W

 

 

 

 

 

784

915

1145

1418

1623

1737

2107

2531

2735

 

 

 

Power cons. in W

 

 

 

 

 

676

722

790

860

907

931

1004

1080

1114

 

 

 

Current cons. in A

 

 

 

 

 

3.09

3.27

3.56

3.88

4.09

4.21

4.55

4.92

5.09

 

 

 

COP in W/W

 

 

 

 

 

1.16

1.27

1.45

1.65

1.79

1.87

2.10

2.34

2.46

 

 

 

ASHRAE MBP

 

 

230V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

-35

-30

-25

-23.3

-20

-15

-10

-6.7

-5

0

5

7.2

10

15

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity in W

 

 

 

 

 

717

836

1049

1305

1500

1609

1965

2379

2581

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power cons. in W

 

 

 

 

 

703

757

838

920

975

1003

1087

1173

1212

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current cons. in A

 

 

 

 

 

3.22

3.43

3.76

4.11

4.35

4.48

4.87

5.28

5.47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COP in W/W

 

 

 

 

 

1.02

1.11

1.25

1.42

1.54

1.60

1.81

2.03

2.13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a3 CSR

a2 e

TOP

c

8227

 

 

 

d

b

 

 

 

Start winding

 

 

e

 

5

2

a2

Main winding

 

 

Winding

4

1

Bleeder resistance

 

 

 

protector

 

 

c

1

1

 

2

2

 

 

N

N

 

 

L

L

 

a3

 

 

 

 

M

Thermostat

Fan

 

Accessories for

SC15MLX.2

Figure

Code number

 

 

 

 

Starting device

 

 

 

 

470 mm cable length

a3

117-7058

 

1000 mm cable length

 

117-7084

 

 

 

 

Cover

 

b

103N2008

 

 

 

 

Starting relay

 

a2

Components

 

 

 

Start. capacitor 125 µF

 

c

of starting

 

 

 

device

Run capacitor 15 µF

 

e

 

 

 

 

 

 

Cord relief

 

d

103N1004

 

 

 

 

Test conditions

EN 12900/CECOMAF

ASHRAE MBP

 

 

 

Condensing temperature

45°C

54.4°C

 

 

 

Ambient temperature

32°C

35°C

 

 

 

Suction gas temperature

32°C

35°C

 

 

 

Liquid temperature

no subcooling

46.1°C

 

 

 

Mounting accessories

 

Code number

 

 

 

Bolt joint for one compressor

Ø: 16 mm

118-1917

 

 

 

Bolt joint in quantities

Ø: 16 mm

118-1918

 

 

 

Snap-on in quantities

Ø: 16 mm

118-1919

 

 

 

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2/2

DEHC.ED.400.N2.02

July 2009

Loading...