SC15GH
Heat Pump Compressor
R134a
220-240V 50/60Hz
General
Code number 104G8561
Approvals EN 60335-2-34, UL984, CCC
Compressors on pallet 80
Application
Application HBP
Frequency Hz 50 60
Evaporating temperature °C -10 to 20 -15 to 15
Voltage range V 198 - 254 198 - 254
Max. condensing temperature continuous (short) °C 70 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C – – F2– – F
38°C – – F2– – F
43°C – – F2– – F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 19.7 –
Cut in Current, HST | LST A 19.7 –
Resistance, main | start winding (25°C) Ω 4.3 15.3
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 1300
Free gas volume in compressor cm
Weight without electrical equipment kg 13.5
Dimensions
Height mm A 209
Suction connector location/I.D. mm | angle C 10.2 | 37°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 8.2 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
3
3
3
B 203
B1 183
B2 100
15.28
500 (polyolester)
1410
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
2
equal to ambient temperature)
2
F2 = Fan cooling 3.0 m/s necessary
2
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.403.X3.02 / 520N0665 1/2

EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 559 664 723 915 1139 1249 1398 1698 2041
Power cons. in W 424 461 479 526 565 580 596 618 632
Current cons. in A 3.33 3.41 3.46 3.59 3.73 3.79 3.87 4.01 4.16
COP in W/W 1.32 1.44 1.51 1.74 2.02 2.15 2.35 2.75 3.23
EN 12900 Household (CECOMAF) 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 425 582 705 776 1012 1295 1436 1629 2019
Power cons. in W 355 424 470 494 566 639 671 711 782
Current cons. in A 2.37 2.67 2.87 2.97 3.24 3.50 3.61 3.74 3.97
COP in W/W 1.20 1.37 1.50 1.57 1.79 2.03 2.14 2.29 2.58
ASHRAE HBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 615 732 796 1008 1255 1376 1541 1872 2252
Power cons. in W 423 460 477 523 562 576 592 614 627
Current cons. in A 3.33 3.41 3.45 3.59 3.72 3.78 3.86 4.00 4.15
COP in W/W 1.45 1.59 1.67 1.93 2.23 2.39 2.60 3.05 3.59
ASHRAE HBP 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 466 639 776 854 1115 1427 1582 1796 2227
Power cons. in W 355 423 469 493 564 635 667 706 775
Current cons. in A 2.37 2.67 2.87 2.96 3.23 3.49 3.60 3.73 3.95
COP in W/W 1.31 1.51 1.66 1.66 1.98 2.25 2.37 2.54 2.87
Accessories for SC15GH Figure Code number Test conditions
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors – Ambient temperature 32°C 35°C
a1
– Condensing temperature 55°C 54.4°C
EN 12900/CECOMAF
ASHRAE HBP
Starting relay 6.3 mm spade connectors a2 117U6011 Suction gas temperature 32°C 35°C
Cover b 103N2008 Liquid temperature 55°C 46.1°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5017
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC g – Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 1 6 mm 118-1918
Snap-on in quantities Ø : 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.403.X3.02 / 520N0665 Dec 2011