Danfoss SC15G Data sheet

SC15G Universal Compressor R134a 115V 60Hz
General
Code number 104G7560
Approvals UL984
Application
Application LBP/HBP
Frequency Hz 50 60
Evaporating temperature °F -31 to 50
Voltage range V 103 - 127
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F O O O
100°F O O O
110°F O O O
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 42.0
Cut in Current, HST | LST A 42.0
Resistance, main | start winding (77°F) 1.0 4.3
Design
Displacement cu.in 0.93
Oil quantity (type) .oz. 20.3 (polyolester)
Maximum refrigerant charge oz. 45.5
Free gas volume in compressor .oz. 49.4
Weight without electrical equipment lbs. 27.7
Dimensions
Height inch A 8.23
Suction connector location, I.D. in. | angle C 0.320-0.327 | 37°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F 0.252-0.259 | –
material | comment Cu-plated steel | Al cap
Remarks:
LBP MBP HBP LBP MBP HBP
B 8.00
B1 7.20
B2 3.93
S = Static cooling normally sufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.A5.22 / 502N1261 1/2
ASHRAE LBP 115V, 60Hz, oil cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 455 780 1088 1241 1837 2570 2876 3440 4448 5595 5725 6222 6884
Power cons. in W 175 252 306 329 408 486 545 566 645 726 753 766 807
Current cons. in A 4.45 4.70 4.91 5.02 5.40 5.85 6.45 6.35 6.91 7.52 8.12 7.84 8.18
EER in BTU/Wh 2.60 3.10 3.56 3.77 4.51 5.28 5.29 6.08 6.89 7.71 7.61 8.12 8.53
ASHRAE HBP 115V, 60Hz, oil cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 403 692 965 1100 1628 2276 2559 3045 3934 4945 5084 5496 6078
Power cons. in W 175 252 306 329 408 486 545 566 645 726 753 766 807
Current cons. in A 4.45 4.70 4.91 5.02 5.40 5.85 6.45 6.35 6.91 7.52 8.12 7.84 8.18
EER in BTU/Wh 2.31 2.75 3.15 3.34 3.99 4.68 4.71 5.38 6.10 6.81 6.76 7.17 7.54
EN 12900 Household (CECOMAF) 115V, 60Hz, oil cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 109 187 260 297 439 614 679 821 1060 1331 1352 1479 1635
Power cons. in W 175 252 306 329 408 486 548 566 645 726 759 766 807
Current cons. in A 4.45 4.70 4.91 5.02 5.40 5.85 6.47 6.35 6.91 7.52 8.15 7.84 8.18
COP in W/W 0.62 0.74 0.85 0.90 1.08 1.26 1.24 1.45 1.64 1.83 1.78 1.93 2.03
Accessories for SC15G Figure Code
number
PTC starting device 1/4 in. spade connect.
3/16 in. spade connect. Ambient temperature 90°F 95°F 90°F
Condensing temp. 130°F 130°F 131°F
Test conditions
ASHRAE
LBP
ASHRAE
HBP
EN 12900/
CECOMAF
Starting relay 1/4 in. spade connect. a2 117U6020 Suction gas temp. 90°F 95°F 90°F
Cover b 103N2008 Liquid temperature 90°F 115°F 131°F
Start. capacitor 240 µF 1/4 in. spade connect. c 117U5023
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC Bolt joint for one comp. Ø : 5/ 8 in . 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.A5.22 / 502N1261 Dec 2011