Danfoss SC15FT Data sheet

SC15FT Tropical Compressor R134a 220-240V 50/60Hz
General
Code number 104G8505
Approvals EN 60335-2-34
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C -35 to -5 -35 to -5
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C F1– F1–
38°C F1– F1–
43°C F2– F2–
Remarks on application:
F1 at 43°C ambient temperature possible at 220V nominal (187-242V)
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 14.8 15.5
Cut in Current, HST | LST A 14.8 19.9
Resistance, main | start winding (25°C) 5.0 13.7
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 1300
Free gas volume in compressor cm
Weight without electrical equipment kg 13.1
Dimensions
Height mm A 209
Suction connector location/I.D. mm | angle C 10.2 | 37°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 6.2 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
3
3
3
B 203
B1 183
B2 100
15.28
550 (polyolester)
1410
S =Staticcoolingnormallysufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.401.C2.02 / 520N0095 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 126 197 280 311 376 489 620 718 772
Power cons. in W 223 267 311 326 356 403 451 483 500
Current cons. in A 2.22 2.31 2.42 2.46 2.54 2.69 2.86 2.98 3.05
COP in W/W 0.56 0.74 0.90 0.95 1.06 1.21 1.38 1.49 1.54
EN 12900 Household (CECOMAF) 220V, 60Hz, fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 154 235 330 365 441 571 724 840 904
Power cons. in W 231 294 356 377 418 478 537 576 596
Current cons. in A 1.87 2.07 2.27 2.34 2.48 2.70 2.93 3.08 3.16
COP in W/W 0.66 0.80 0.92 0.97 1.05 1.19 1.35 1.46 1.52
ASHRAE LBP 220V, 50Hz, fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 157 245 347 385 466 606 769 890 958
Power cons. in W 224 267 311 326 356 402 450 482 499
Current cons. in A 2.22 2.31 2.42 2.46 2.54 2.69 2.86 2.98 3.04
COP in W/W 0.70 0.92 1.12 1.18 1.31 1.51 1.71 1.85 1.92
ASHRAE LBP 220V, 60Hz, fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 192 292 409 452 546 708 899 1042 1123
Power cons. in W 232 295 357 377 417 477 536 574 594
Current cons. in A 1.88 2.07 2.27 2.34 2.48 2.69 2.92 3.07 3.16
COP in W/W 0.83 0.99 1.15 1.20 1.31 1.48 1.68 1.81 1.89
Accessories for SC15FT Figure Code number Test conditions
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors Ambient temperature 32°C 32°C
a1
103N0002 Condensing temperature 55°C 55°C
EN 12900/CECOMAF
ASHRAE LBP
Starting relay 6.3 mm spade connectors a2 117U6005 Suction gas temperature 32°C 32°C
Cover b 103N2009 Liquid temperature 55°C 32°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5017
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC g Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 1 6 mm 118-1918
Snap-on in quantities Ø : 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.C2.02 / 520N0095 Dec 2011