Danfoss SC15CLX.2 LBP Data sheet

SC15CLX.2 LBP Compressor R404A/R507 115V 60Hz
General
Code number 104L1853
Approvals UL984
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °F -40 to 20
Voltage range V 95 - 127
Max. condensing temperature continuous (short) °F 131 (140)
Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F F2–
100°F F
110°F
Remarks on application: CSR: 95-127V/60Hz, CSIR: 103-127V/60Hz
Motor
Motor type CSIR/CSR
LRA (rated after 4 sec. UL984), HST | LST A 53.0
Cut in Current, HST | LST A 53.0
Resistance, main | start winding (77°F) 0.9 2.9
Design
Displacement cu.in 0.93
Oil quantity (type) .oz. 20.3 (polyolester)
Maximum refrigerant charge oz. 45.5
Free gas volume in compressor .oz. 49.4
Weight without electrical equipment lbs. 30.9
Dimensions
Height inch A 8.62
Suction connector location, I.D. in. | angle C 0.378-0.385 | 37°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
2
B 8.39
B1 7.60
B2 4.33
S = Static cooling normally sufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.G2.22 / 520N0035 1/2
ASHRAE LBP 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 889 1471 2167 2735 3000 3992 5166 5692 6546
Power cons. in W 424 526 627 698 729 833 941 986 1056
Current cons. in A 7.42 8.01 8.61 9.04 9.23 9.88 10.54 10.82 11.23
EER in BTU/Wh 2.10 2.79 3.45 3.92 4.12 4.79 5.49 5.77 6.20
ASHRAE LBP* 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 1250 1835 2542 3118 3388 4392 5572 6098 6948
Power cons. in W 439 523 607 668 694 785 883 924 989
Current cons. in A 7.55 8.04 8.56 8.93 9.09 9.65 10.22 10.46 10.82
EER in BTU/Wh 2.85 3.51 4.18 4.67 4.88 5.59 6.31 6.60 7.03
EN 12900 Household (CECOMAF)* 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 1039 1544 2152 2647 2879 3740 4751 5201 5927
Power cons. in W 438 524 611 672 699 792 891 932 998
Current cons. in A 7.53 8.04 8.57 8.95 9.12 9.69 10.28 10.52 10.89
EER in BTU/Wh 2.37 2.95 3.52 3.94 4.12 4.72 5.33 5.58 5.94
Accessories for SC15CLX.2 Figure Code
number
Starting device assembly
CSR 23.6 in. cable length 117-7045 Ambient temperature 90°F 90°F 90°F
CSIR 23.6 in. cable length 117-7053 Suction gas temp. 90°F 90°F 90°F
a3
Test conditions
ASHRAE
LBP
ASHRAE
LBP*
EN 12900/
CECOMAF*
Condensing temp. 130°F 110°F 113°F
Liquid temperature 90°F 90°F no subcooling
Starting device components
Starting relay 1/4 in. spade connect. a2 117-7441
Start. capacitor 410 µF 1/4 in. spade connect. c 117U5043
Run capacitor 23.5 µF 1/4 in. spade connect. e 117-7114
Cover b 117U1021 *
Protector f 117U3212 *
Protector holder h 117U0439 *
)
*
Remarks: Cover, protector, protector holder parts of compressor Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
)
Mounting accessories Code number
)
Bolt joint for one comp. Ø : 5/ 8 in . 118-1917
)
Bolt joint in quantities Ø: 5/8 in. 118-1918
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.G2.22 / 520N0035 Dec 2011