SC15/15CL LBP/MBP Twin Compressor R404A/R507 220-240V 50Hz
General
Code number 104L4089
Approvals EN 60335-2-34
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °C -40 to -5
Voltage range V 198 - 254
Max. condensing temperature continuous (short) °C 55 (60)
Max. winding temperature continuous (short) °C 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C F2F2–
38°C F
43°C
Remarks on application:
LBP MBP HBP LBP MBP HBP
2F2
S =Staticcoolingnormallysufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984) *, HST | LST A 2 x 18.6
Cut in Current *, HST | LST A 2 x 18.6
Resistance, main | start winding (25°C) 3.7 14.1
* Operational current for the second compressor time-delayed.
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 2200
Free gas volume in compressor cm
Weight without electrical equipment kg 29.1
Dimensions
Height mm A 259
Suction connector (service valve) location/I.D. mm C 12 | 37°
Suction connector (solder connector) location/I.D. mm C 12 | 37°
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 6.2 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09
Remarks:
3
3
3
1220 (polyolester)
B 254
B1 193
B2 110
2 x 15.28
2920
Dec 2011 Manufactured by Secop for Danfoss - CF.54.H3.02 / 520N1183 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 302 599 905 1230 1347 1584 1976 2417 2739 2916
Power cons. in W 597 801 970 1120 1169 1262 1411 1580 1709 1782
Current cons. in A 5.66 6.10 6.56 7.04 7.21 7.55 8.08 8.62 9.00 9.19
COP in W/W 0.51 0.75 0.93 1.10 1.15 1.25 1.40 1.53 1.60 1.64
ASHRAE LBP/MBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 350 694 1050 1428 1563 1840 2298 2813 3177 3398
Power cons. in W 597 801 970 1120 1169 1262 1411 1580 1709 1782
Current cons. in A 5.66 6.10 6.56 7.04 7.21 7.55 8.08 8.62 9.00 9.19
COP in W/W 0.59 0.87 1.08 1.27 1.34 1.46 1.63 1.78 1.86 1.91
Accessories SC15/15CL pcs. Code number Test conditions
EN 12900/
CECOMAF
ASHRAE
LBP/MBP
Starting device 470 mm cable length Condensing temperature 45°C 45°C
550 mm cable length 2 Ambient temperature 32°C 32°C
650 mm cable length Suction gas temperature 32°C 32°C
Starting relay 6.3 mm spade connectors 2 117U6019 Liquid temperature no subcooling 32°C
Start. capacitor 80 µF 6.3 mm spade connectors 2 117U5017
Cover 2 103N2009
Cord relief 2 103N1004
Time-delay relay 1 117N0001
Check valve (to be used with time-delay relay) 2 020-1014
Service valve 12 mm 1 118-7350
Solder connector (alternative) 12 mm 1 104B0584
Service valve 16 mm 1
Solder connector (alternative) 16 mm 1
Seal ring for service valve and solder connector 1 118-3638
Mounting accessories pcs. Code number
Bolt joint for one compressor Ø: 16 mm 2 118-1917
Bolt joint in quantities Ø: 16 mm 2 118-1918
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to