SC12MLX
MBP Compressor
R404A/R507
115V 60Hz
General
Code number 104L1606
Approvals UL984
Compressors on pallet 60
Application
Application MBP
Frequency Hz 50 60
Evaporating temperature °F – -10 to 45
Voltage range V – 95 - 135
Max. condensing temperature continuous (short) °F – 131 (140)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F – – – – F2–
100°F – – – – F
110°F – – – – F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 53.0 –
Cut in Current, HST | LST A 53.0 –
Resistance, main | start winding (77°F) Ω 0.7 2.9
Design
Displacement cu.in 0.78
Oil quantity (type) .oz. 20.3 (polyolester)
Maximum refrigerant charge oz. 45.5
Free gas volume in compressor .oz. 49.4
Weight without electrical equipment lbs. 30.2
Dimensions
Height inch A 8.62
Suction connector location, I.D. in. | angle C 0.320-0.327 | 37°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
LBP MBP HBP LBP MBP HBP
2
2
B 8.39
B1 7.60
B2 4.33
S = Static cooling normally sufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
–
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
–
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.B2.22 / 520N0030 1/2

ASHRAE MBP 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 1987 2640 3435 3797 4391 5527 6865 7011 7616
Power cons. in W 581 676 770 808 865 960 1058 1067 1107
Current cons. in A 7.93 8.50 9.13 9.40 9.83 10.58 11.39 11.48 11.82
EER in BTU/Wh 3.42 3.90 4.46 4.70 5.08 5.76 6.49 6.57 6.88
EN 12900 Household (CECOMAF)* 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 668 780 978 1211 1387 1484 1799 2160 2335
Power cons. in W 590 633 698 765 810 834 906 982 1017
Current cons. in A 7.94 8.19 8.62 9.09 9.43 9.62 10.19 10.81 11.10
COP in W/W 1.13 1.23 1.40 1.58 1.71 1.78 1.99 2.20 2.30
Accessories for SC12MLX Figure Code number Test conditions
Starting device assembly
CSR 23.6 in. cable length – Ambient temperature 95°F 90°F
CSIR 23.6 in. cable length 117-7053 Suction gas temp. 95°F 90°F
a3
Condensing temp. 130°F 113°F
ASHRAE MBP
EN 12900/CECOMAF*
Liquid temperature 115°F no subcooling
Starting device components
Starting relay 1/4 in. spade connect. a2 117-7441
Start. capacitor 410 µF 1/4 in. spade connect. c 117U5042
Run capacitor 23.5 µF 1/4 in. spade connect. e –
Cover b 117U1021 *
Protector f 117U3212 *
Protector holder h 117U0439 *
)
*
Remarks: Cover, protector, protector holder parts of compressor Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
)
Mounting accessories Code number
)
Bolt joint for one comp. Ø : 5/ 8 in . 118-1917
)
Bolt joint in quantities Ø : 5/ 8 in . 118-1918
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.B2.22 / 520N0030 Dec 2011