Danfoss SC12GH Data sheet

SC12GH Heat Pump Compressor R134a 220-240V 50/60Hz
General
Code number 104G8261
Approvals EN 60335-2-34, UL984
Application
Application HBP
Frequency Hz 50 60
Evaporating temperature °C -10 to 20 -15 to 15
Voltage range V 198 - 254 198 - 254
Max. condensing temperature continuous (short) °C 70 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C F2– F
38°C F2– F
43°C F2– F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 19.7
Cut in Current, HST | LST A 19.7
Resistance, main | start winding (25°C) 4.3 15.3
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 1300
Free gas volume in compressor cm
Weight without electrical equipment kg 12.95
Dimensions
Height mm A 209
Suction connector location/I.D. mm | angle C 10.2 | 37°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 8.2 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
3
3
3
B 203
B1 183
B2 100
12.87
500 (polyolester)
1510
S =Staticcoolingnormallysufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature
2
equal to ambient temperature)
2
F2 = Fan cooling 3.0 m/s necessary
2
SG =Suctiongascoolingnormallysufcent
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.403.W2.02 / 520N0598 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 429 524 577 752 957 1058 1196 1471 1787
Power cons. in W 356 386 401 445 487 505 526 561 590
Current cons. in A 3.08 3.16 3.21 3.34 3.47 3.53 3.60 3.73 3.86
COP in W/W 1.20 1.36 1.44 1.69 1.97 2.10 2.27 2.62 3.03
EN 12900 Household (CECOMAF) 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 371 511 619 680 880 1116 1233 1393 1714
Power cons. in W 332 389 426 445 501 556 579 608 658
Current cons. in A 2.37 2.61 2.76 2.84 3.06 3.28 3.37 3.49 3.68
COP in W/W 1.12 1.31 1.45 1.53 1.76 2.01 2.13 2.29 2.60
ASHRAE HBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 474 579 637 830 1055 1166 1318 1622 1972
Power cons. in W 356 385 400 443 484 502 522 556 584
Current cons. in A 3.08 3.16 3.20 3.33 3.46 3.52 3.59 3.72 3.84
COP in W/W 1.33 1.50 1.59 1.87 2.18 2.33 2.52 2.92 3.38
ASHRAE HBP 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 409 564 682 749 970 1230 1359 1536 1890
Power cons. in W 332 388 425 444 499 552 575 604 653
Current cons. in A 2.37 2.61 2.76 2.83 3.05 3.26 3.35 3.47 3.66
COP in W/W 1.23 1.45 1.61 1.69 1.94 2.23 2.36 2.54 2.90
Accessories for SC12GH Figure Code number Test conditions
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors Ambient temperature 32°C 35°C
a1
Condensing temperature 55°C 55°C
EN 12900/CECOMAF
ASHRAE HBP
Starting relay 6.3 mm spade connectors a2 117U6011 Suction gas temperature 32°C 35°C
Cover b 103N2008 Liquid temperature 55°C 46.1°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5017
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC g Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 1 6 mm 118-1918
Snap-on in quantities Ø : 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.403.W2.02 / 520N0598 Dec 2011
Loading...