SC12G
Universal Compressor
R134a
115V 60Hz
General
Code number 104G7250
Approvals UL984
Compressors on pallet 80
Application
Application LBP/HBP
Frequency Hz 50 60
Evaporating temperature °F – -31 to 50
Voltage range V – 103 - 127
Max. condensing temperature continuous (short) °F – 140 (158)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F – – – F1F1F
100°F – – – F1F1F
110°F – – – F1F1F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 42.0 –
Cut in Current, HST | LST A 42.0 –
Resistance, main | start winding (77°F) Ω 1.0 4.3
Design
Displacement cu.in 0.78
Oil quantity (type) .oz. 18.6 (polyolester)
Maximum refrigerant charge oz. 45.5
Free gas volume in compressor .oz. 49.4
Weight without electrical equipment lbs. 27.7
Dimensions
Height inch A 8.23
Suction connector location, I.D. in. | angle C 0.320-0.327 | 37°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
LBP MBP HBP LBP MBP HBP
B 8.00
B1 7.20
B2 3.93
S = Static cooling normally sufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
1
equal to ambient temperature)
1
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
1
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.A6.22 / 502N1257 1/2
ASHRAE LBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 243 551 833 972 1507 2157 2399 2924 3807 4808 4896 5354 5930
Power cons. in W 157 212 252 269 328 389 443 451 516 581 603 615 649
Current cons. in A 4.42 4.56 4.70 4.76 5.01 5.31 5.82 5.66 6.05 6.49 6.98 6.72 6.97
EER in BTU/Wh 1.55 2.60 3.31 3.61 4.59 5.55 5.43 6.48 7.38 8.27 8.12 8.71 9.14
ASHRAE HBP 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 216 488 739 861 1335 1911 2136 2588 3367 4250 4350 4730 5236
Power cons. in W 157 212 252 269 328 389 443 451 516 581 606 615 649
Current cons. in A 4.42 4.56 4.70 4.76 5.01 5.31 5.82 5.66 6.05 6.49 7.00 6.72 6.97
EER in BTU/Wh 1.38 2.30 2.93 3.20 4.07 4.91 4.81 5.73 6.53 7.31 7.23 7.69 8.07
EN 12900 Household (CECOMAF) 115V, 60Hz, fan cooling F
1
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W
Power cons. in W
Current cons. in A
COP in W/W
58 132 199 232 360 515 563 698 907 1144 1151 1273 1409
157 212 252 269 328 389 444 451 516 581 606 615 649
4.42 4.56 4.70 4.76 5.01 5.31 5.82 5.66 6.05 6.49 7.00 6.72 6.97
0.37 0.62 0.79 0.86 1.10 1.33 1.27 1.55 1.76 1.97 1.90 2.07 2.17
Accessories for SC12G Figure Code
number
PTC starting device 1/4 in. spade connect.
3/16 in. spade connect. – Ambient temperature 90°F 95°F 90°F
–
– Condensing temp. 130°F 130°F 131°F
Test conditions
ASHRAE
LBP
ASHRAE
HBP
EN 12900/
CECOMAF
Starting relay 1/4 in. spade connect. a2 117U6020 Suction gas temp. 90°F 95°F 90°F
Cover b 103N2008 Liquid temperature 90°F 115°F 131°F
Start. capacitor 240 µF 1/4 in. spade connect. c 117U5023
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC – – Bolt joint for one comp. Ø : 5/ 8 in . 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.A6.22 / 502N1257 Dec 2011