Danfoss SC12FTX Data sheet

SC12FTX Tropical Compressor R134a 115-127V 60Hz
General
Code number 104G7205
Approvals UL984
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F -31 to 23
Voltage range V 95 - 135
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F F2F2–
100°F F
110°F F
Remarks on application: Not applicable below -20°F evaporating temperature in 110°F
ambient temperature above 127V.
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 38.2
Cut in Current, HST | LST A 38.2
Resistance, main | start winding (77°F) 1.2 4.2
Design
Displacement cu.in 0.78
Oil quantity (type) .oz. 20.3 (polyolester)
Maximum refrigerant charge oz. 45.5
Free gas volume in compressor .oz. 49.4
Weight without electrical equipment lbs. 27.7
Dimensions
Height inch A 8.23
Suction connector location, I.D. in. | angle C 0.320-0.327 | 37°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
2F2
2F2
B 8.00
B1 7.20
B2 3.93
S = Static cooling normally sufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.I2.22 / 502N1256 1/2
ASHRAE 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 563 889 1155 1280 1753 2324 2583 3008
Power cons. in W 244 302 343 360 419 478 502 537
Current cons. in A 5.01 5.28 5.48 5.57 5.88 6.20 6.34 6.55
EER in BTU/Wh 2.30 2.94 3.37 3.55 4.18 4.86 5.15 5.60
EN 12900 Household (CECOMAF) 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 132 210 273 303 415 549 610 710
Power cons. in W 244 302 343 360 419 478 502 537
Current cons. in A 5.01 5.28 5.48 5.57 5.88 6.20 6.34 6.55
COP in W/W 0.54 0.70 0.80 0.84 0.99 1.15 1.21 1.32
Accessories for SC12FTX Figure Code
number
PTC starting device 1/4 in. spade connect.
3/16 in. spade connect. Ambient temperature 90°F 90°F
Condensing temp. 130°F 131°F
Test conditions
ASHRAE
EN 12900/
CECOMAF
Starting relay 1/4 in. spade connect. a2 117U6012 Suction gas temp. 90°F 90°F
Cover b 103N2008 Liquid temperature 90°F 131°F
Start. capacitor 240 µF 1/4 in. spade connect. c 117U5023
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC Bolt joint for one comp. Ø : 5/ 8 in . 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.I2.22 / 502N1256 Dec 2011
Loading...