Danfoss SC12FT Data sheet

SC12FT Tropical Compressor R134a 220-240V 50/60Hz
General
Code number 104G8205
Approvals EN 60335-2-34
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C -35 to -5 -35 to -5
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C F1– F1–
38°C F1– F1–
43°C F2– F2–
Remarks on application:
F1 at 43°C ambient temperature possible at 220V nominal (187-242V)
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 12.6 12.4
Cut in Current, HST | LST A 12.6 17.2
Resistance, main | start winding (25°C) 6.7 11.8
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 1300
Free gas volume in compressor cm
Weight without electrical equipment kg 12.6
Dimensions
Height mm A 209
Suction connector location/I.D. mm | angle C 8.2 | 37°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 6.2 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09
Remarks:
LBP MBP HBP LBP MBP HBP
3
3
3
B 203
B1 183
B2 100
12.87
550 (polyolester)
1510
S =Staticcoolingnormallysufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.C5.02 / 520N1207 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 103 163 233 259 314 408 517 599 645
Power cons. in W 184 226 265 278 303 341 380 407 422
Current cons. in A 193 245 298 316 351 405 458 2.55 511
COP in W/W 0.56 0.72 0.88 0.93 1.03 1.20 1.36 1.47 1.53
EN 12900 Household (CECOMAF) 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 125 192 272 302 366 477 608 706 761
Power cons. in W 193 245 298 316 351 405 458 496 511
Current cons. in A 1.58 1.75 1.92 1.98 2.10 2.30 2.50 2.63 2.71
COP in W/W 0.64 0.78 0.91 0.96 1.04 1.18 1.33 1.43 1.49
ASHRAE LBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 126 201 287 320 387 503 639 741 798
Power cons. in W 184 226 265 278 303 341 380 407 422
Current cons. in A 193 245 298 316 351 405 458 2.55 511
COP in W/W 0.69 0.89 1.08 1.15 1.28 1.48 1.68 1.82 1.89
ASHRAE LBP 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 153 237 336 373 452 589 751
874 942
Power cons. in W 193 245 298 316 351 405 458 493 511
Current cons. in A 1.58 1.75 1.92 1.98 2.10 2.30 2.50 2.63 2.71
COP in W/W 0.79 0.97 1.13 1.18 1.29 1.46 1.64
1.77 1.84
Accessories for SC12FT Figure Code number Test conditions
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors Ambient temperature 32°C 32°C
a1
103N0002 Condensing temperature 55°C 55°C
EN 12900/CECOMAF
ASHRAE LBP
Starting relay 6.3 mm spade connectors a2 117U6003 Suction gas temperature 32°C 32°C
Cover b 103N2009 Liquid temperature 55°C 32°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5017
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC g Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 1 6 mm 118-1918
Snap-on in quantities Ø : 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.C5.02 / 520N1207 Dec 2011
Loading...