Danfoss SC12CLX.2 Data sheet

Danfoss SC12CLX.2 Data sheet

SC12CLX.2

LBP Compressor R404A/R507 208-230V 60Hz

General

Code number

 

 

 

 

104L2699

 

 

 

Approvals

 

 

 

UL984/CSA-C22.2

 

Compressors on pallet

 

 

 

 

80

 

 

 

 

Application

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

LBP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

Evaporating temperature

 

°F

 

 

 

-49 to 14

 

 

 

 

 

 

 

 

 

 

Voltage range

 

V

 

 

 

187 -254

 

 

 

 

 

 

 

Max. condensing temperature continuous (short)

°F

 

 

 

122 (140)

 

 

 

 

 

 

 

Max. winding temperature continuous (short)

°F

 

 

 

257 (275)

 

 

 

 

 

 

 

 

 

 

 

Cooling requirements

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Application

 

 

LBP

MBP

HBP

 

LBP

MBP

 

HBP

90°F

 

 

 

F2

 

100°F

 

 

 

F2

 

110°F

 

 

 

F2

 

Remarks on application:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

 

CSR

 

 

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

19.6

 

 

 

 

Cut in Current, HST | LST

 

A

 

19.6

 

 

 

 

Resistance, main | start winding (77°F)

Ω

 

3.8

 

 

 

13.7

 

 

Design

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Displacement

 

cu.in

 

 

0.78

 

 

 

 

 

 

 

 

 

Oil quantity (type)

 

fl.oz.

 

18.6 (polyolester)

 

 

 

 

 

 

 

 

 

 

Maximum refrigerant charge

 

oz.

 

 

45.8

 

 

 

 

 

 

 

 

 

 

 

 

Free gas volume in compressor

 

fl.oz.

 

 

51.1

 

 

 

 

 

 

 

 

 

 

 

 

Weight without electrical equipment

 

lbs.

 

 

27.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

Height

 

inch

A

 

8.62

 

 

 

 

 

 

B

 

8.39

 

 

 

 

 

 

B1

 

7.60

 

 

 

 

 

 

B2

 

4.33

 

 

 

Suction connector

location, I.D. in. | angle

C

0.378-0.385 | 37°

 

 

 

material | comment

 

Cu-plated steel | Al caps

 

Process connector

location, I.D. in. | angle

D

0.252-0.259 | 37°

 

 

 

material | comment

 

Cu-plated steel | Al caps

 

Discharge connector

location, I.D. in. | angle

E

0.252-0.259 | 37°

 

 

 

material | comment

 

Cu-plated steel | Al caps

 

Oil cooler connector

location, I.D. in. | angle

F

 

 

 

 

 

 

material | comment

 

 

 

 

 

 

Remarks:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SC12CLX.2

104L

 

Application

R404A

 

 

 

 

 

 

 

 

R507

 

 

Lilac stripe

 

 

2699

 

Approvals

 

 

 

 

Barcode on

 

 

<![if ! IE]>

<![endif]>-7

white background

 

 

<![if ! IE]>

<![endif]>8469

Yellow background

 

 

DANFOSS COMPRESSORS

 

 

 

 

 

 

 

 

R

 

 

 

 

 

SC12CLX.2

 

 

 

 

230V-60Hz

 

 

 

 

 

1PH

 

 

 

 

 

THERMALLY

<![if ! IE]>

<![endif]>8469-2

 

 

 

 

PROTECTED

 

 

 

 

 

Approval mark

S = Static cooling normally su cient

O= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally su cent

= not applicable in this area

<![if ! IE]>

<![endif]>5.94"(151)

2.17"(55)

37°

37°

2.48"(63)

2.17"(55)

<![if ! IE]>

<![endif]>2.48"(63)

 

 

 

 

 

 

 

4.21"(107)

4.21"(107)

 

 

 

D

 

 

4.53"(115)

 

C

 

 

 

 

 

 

8.58"(218)

 

 

 

E

B1

 

B A

 

 

 

0.12"(3)

B2

 

 

 

 

 

10.04"(255)

 

 

ø0.63"(16)

8.03"(204)

ø0.75"(19)

7.01"(178)

 

 

 

 

 

 

6.69"(170)

ø0.38"(9.7)

5"(127)

4"(101.6)

1.38"(35)

 

2.76"(70)

5.91"(150)

 

 

 

5"(127)

 

 

 

 

 

6.50"(165)

8393

 

 

 

7.32"(186)

 

 

 

 

 

July 2005

DEHC.ED.401.X1.22

1/2

ASHRAE LBP

 

 

230V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

-49

-40

-30

-20

-13

-10

0

10

14

20

30

40

41

45

50

59

68

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity in BTU/h

281

649

1133

1712

2183

2404

3229

4205

4642

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power cons. inW

264

334

409

482

534

556

632

711

744

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current cons. in A

1.57

1.71

1.88

2.08

2.23

2.30

2.54

2.80

2.91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER in BTU/Wh

1.06

1.94

2.77

3.55

4.09

4.32

5.11

5.91

6.24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASHRAE LBP*

 

 

230V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

-49

-40

-30

-20

-13

-10

0

10

14

20

30

40

41

45

50

59

68

Capacity in BTU/h

598

962

1449

2036

2516

2740

3575

4556

4994

 

 

 

 

 

 

 

 

Power cons. inW

289

345

406

468

512

531

598

669

699

 

 

 

 

 

 

 

 

Current cons. in A

1.72

1.82

1.95

2.11

2.23

2.29

2.49

2.72

2.81

 

 

 

 

 

 

 

 

EER in BTU/Wh

2.07

2.79

3.57

4.35

4.91

5.16

5.98

6.81

7.15

 

 

 

 

 

 

 

 

EN 12900 Household (CECOMAF)

230V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

-49

-40

-30

-20

-13

-10

0

10

14

20

30

40

41

45

50

59

68

Capacity in BTU/h

481

796

1216

1721

2133

2326

3042

3883

4257

 

 

 

 

 

 

 

 

Power cons. inW

286

344

407

470

515

535

602

674

705

 

 

 

 

 

 

 

 

Current cons. in A

1.70

1.81

1.95

2.11

2.24

2.29

2.50

2.73

2.83

 

 

 

 

 

 

 

 

EER in BTU/Wh

1.68

2.31

2.99

3.66

4.14

4.35

5.05

5.76

6.04

 

 

 

 

 

 

 

 

a3

a2 e

TOP

c

8227

 

 

 

d

b

 

 

 

Start winding

 

 

e

 

5

2

a2

Main winding

 

 

Winding

4

1

Bleeder resistance

 

 

 

protector

 

 

c

1

1

 

2

2

 

 

N

N

 

 

L

L

 

a3

 

 

 

 

 

 

M

Thermostat

 

 

Fan

 

 

 

Accessories for

SC12CLX.2 (60Hz)

Figure

Code number

Starting device

 

 

 

 

18.5 in. cable length

 

117-7012

 

21.7 in. cable length

a3

117-7027

 

26.6 in. cable length

 

117-7046

 

39.4 in. cable length

 

117-7040

Cover

 

b

103N2008

Starting relay

 

a2

Components

Start. capacitor 80 µF

 

c

of starting

Run capacitor 10 µF

 

e

device

 

 

Cord relief

 

d

103N1004

Test conditions

ASHRAE LBP

ASHRAE LBP*

EN 12900/CECOMAF*

Condensing temp.

130°F

110°F

113°F

Ambient temperature

90°F

90°F

90°F

Suction gas temp.

90°F

90°F

90°F

Liquid temperature

90°F

90°F

no subcooling

Mounting accessories

 

Code number

Bolt joint for one comp.

Ø: 5/8 in.

118-1917

Bolt joint in quantities

Ø: 5/8 in.

118-1918

Snap-on in quantities

Ø: 5/8 in.

118-1919

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice.This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2/2

DEHC.ED.401.X1.22

July 2005

Loading...