Danfoss SC12CL Data sheet

SC12CL LBP Compressor R404A/R507 115V 60Hz
General
Code number 104L1603
Approvals UL984
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °F -40 to 10
Voltage range V 103 - 127
Max. condensing temperature continuous (short) °F 131 (140)
Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F F2–
100°F F
110°F F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 41.9
Cut in Current, HST | LST A 41.9
Resistance, main | start winding (77°F) 1.0 4.3
Design
Displacement cu.in 0.78
Oil quantity (type) .oz. 18.6 (polyolester)
Maximum refrigerant charge oz. 45.8
Free gas volume in compressor .oz. 51.1
Weight without electrical equipment lbs. 27.7
Dimensions
Height inch A 8.23
Suction connector location, I.D. in. | angle C 0.320-0.327 | 37°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
2
2
B 8.00
B1 7.20
B2 3.93
S = Static cooling normally sufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - CF.54.U3.22 / 520N1189 1/2
ASHRAE LBP 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 143 842 1577 2127 2374 3255 4246
Power cons. in W 212 374 510 595 629 739 848
Current cons. in A 4.92 5.44 6.08 6.60 6.84 7.73 8.74
EER in BTU/Wh 0.68 2.25 3.09 3.58 3.77 4.40 5.01
ASHRAE LBP* 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 648 1229 1871 2366 2592 3414 4356
Power cons. in W 322 436 535 599 627 720 822
Current cons. in A 5.32 5.69 6.17 6.59 6.78 7.52 8.38
EER in BTU/Wh 2.01 2.82 3.50 3.95 4.14 4.74 5.30
EN 12900 Household (CECOMAF)* 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 146 297 463 590 648 857 1095
Power cons. in W 308 429 533 600 628 723 826
Current cons. in A 5.26 5.64 6.15 6.58 6.79 7.55 8.43
COP in W/W 0.48 0.69 0.87 0.98 1.03 1.18 1.33
Accessories for SC12CL Figure Code
number
PTC starting device 1/4 in. spade connect.
3/16 in. spade connect. Ambient temperature 90°F 90°F 90°F
Condensing temp. 130°F 110°F 113°F
Test conditions
ASHRAE
LBP
ASHRAE
LBP*
EN 12900/
CECOMAF*
Starting relay 1/4 in. spade connect. a2 117U6020 Suction gas temp. 90°F 90°F 90°F
Cover b 103N2008 Liquid temperature 90°F 90°F no subcooling
Start. capacitor 240 µF 1/4 in. spade connect. c 117U5023
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC Bolt joint for one comp. Ø : 5/ 8 in . 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - CF.54.U3.22 / 520N1189 Dec 2011