Danfoss SC12CL Data sheet

Danfoss SC12CL Data sheet

SC12CL

LBP Compressor R404A/R507 115V 60Hz

General

Code number

 

 

 

 

 

104L1603

 

 

 

Approvals

 

 

 

 

 

UL984

 

 

 

Compressors on pallet

 

 

 

 

 

80

 

 

 

Application

 

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

 

LBP

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Evaporating temperature

 

°F

 

 

 

 

-40 to 10

Voltage range

 

V

 

 

 

 

103 - 127

Max. condensing temperature continuous (short)

°F

 

 

 

 

131 (140)

Max. winding temperature continuous (short)

°F

 

 

 

 

257 (275)

Cooling requirements

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Application

 

 

LBP

 

MBP

HBP

 

LBP

MBP

 

HBP

90°F

 

 

 

 

F2

 

100°F

 

 

 

 

F2

 

110°F

 

 

 

 

F2

 

Remarks on application:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

 

 

CSIR

 

 

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

41.9

 

 

 

 

Cut in Current, HST | LST

 

A

 

41.9

 

 

 

 

Resistance, main | start winding (77°F)

 

1.0

 

 

 

4.3

 

 

Design

 

 

 

 

 

 

 

 

 

 

 

Displacement

 

cu.in

 

 

 

0.78

 

 

 

Oil quantity (type)

 

fl.oz.

 

 

18.6 (polyolester)

 

Maximum refrigerant charge

 

oz.

 

 

 

45.8

 

 

 

Free gas volume in compressor

 

fl.oz.

 

 

 

51.1

 

 

 

Weight without electrical equipment

lbs.

 

 

 

27.7

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

Height

 

inch

A

 

 

8.23

 

 

 

 

 

 

B

 

 

8.00

 

 

 

 

 

 

B1

 

 

7.20

 

 

 

 

 

 

B2

 

 

3.93

 

 

 

Suction connector

location, I.D. in. | angle

C

0.320-0.327 | 37°

 

 

 

material | comment

 

Cu-plated steel | Al cap

 

Process connector

location, I.D. in. | angle

D

0.252-0.259 | 37°

 

 

 

material | comment

 

Cu-plated steel | Al cap

 

Discharge connector

location, I.D. in. | angle

E

0.252-0.259 | 37°

 

 

 

material | comment

 

Cu-plated steel | Al cap

 

Oil cooler connector

location, I.D. in. | angle

F

 

 

 

 

 

 

 

material | comment

 

 

 

 

 

 

 

Remarks:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

= Static cooling normally sufficient

O

= Oil cooling

F1

= Fan cooling 1.5 m/s

 

 

(compressor compartment temperature

 

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

Dec 2011

Manufactured by Secop for Danfoss - CF.54.U3.22 / 520N1189

1/2

ASHRAE LBP

 

 

115V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

-49

-40

-30

-20

-13

 

-10

0

10

14

20

30

40

41

45

50

59

68

Capacity in BTU/h

 

143

842

1577

2127

2374

3255

4246

 

 

 

 

 

 

 

 

 

 

Power cons. in W

 

212

374

510

595

629

739

848

 

 

 

 

 

 

 

 

 

 

Current cons. in A

 

4.92

5.44

6.08

6.60

6.84

7.73

8.74

 

 

 

 

 

 

 

 

 

 

EER in BTU/Wh

 

0.68

2.25

3.09

3.58

3.77

4.40

5.01

 

 

 

 

 

 

 

 

 

 

ASHRAE LBP*

 

 

115V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

-49

-40

-30

-20

-13

 

-10

0

10

14

20

30

40

41

45

50

59

68

Capacity in BTU/h

 

648

1229

1871

2366

2592

3414

4356

 

 

 

 

 

 

 

 

 

 

Power cons. in W

 

322

436

535

599

627

720

822

 

 

 

 

 

 

 

 

 

 

Current cons. in A

 

5.32

5.69

6.17

6.59

6.78

7.52

8.38

 

 

 

 

 

 

 

 

 

 

EER in BTU/Wh

 

2.01

2.82

3.50

3.95

4.14

4.74

5.30

 

 

 

 

 

 

 

 

 

 

EN 12900 Household (CECOMAF)* 115V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

-49

-40

-30

-20

-13

 

-10

0

10

14

20

30

40

41

45

50

59

68

Capacity in W

 

146

297

463

590

648

857

1095

 

 

 

 

 

 

 

 

 

 

Power cons. in W

 

308

429

533

600

628

723

826

 

 

 

 

 

 

 

 

 

 

Current cons. in A

 

5.26

5.64

6.15

6.58

6.79

7.55

8.43

 

 

 

 

 

 

 

 

 

 

COP in W/W

 

0.48

0.69

0.87

0.98

1.03

1.18

1.33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessories for

SC12CL

Figure

Code

 

 

 

number

 

 

 

 

PTC starting device

1/4 in. spade connect.

 

3/16 in. spade connect.

 

 

Starting relay

1/4 in. spade connect.

a2

117U6020

Cover

 

b

103N2008

Start. capacitor 240 µF

1/4 in. spade connect.

c

117U5023

Cord relief

 

d

103N1004

Protection screen for PTC

Test conditions

ASHRAE

ASHRAE

EN 12900/

 

LBP

LBP*

CECOMAF*

 

 

 

 

Condensing temp.

130°F

110°F

113°F

Ambient temperature

90°F

90°F

90°F

Suction gas temp.

90°F

90°F

90°F

Liquid temperature

90°F

90°F

no subcooling

Mounting accessories

 

Code number

Bolt joint for one comp.

Ø: 5/8 in.

118-1917

Bolt joint in quantities

Ø: 5/8 in.

118-1918

Snap-on in quantities

Ø: 5/8 in.

118-1919

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2/2

Manufactured by Secop for Danfoss - CF.54.U3.22 / 520N1189

Dec 2011

Loading...