General

Code number

 

 

 

 

 

104G8041

 

 

 

Approvals

 

 

EN 60335-2-34, UL984, CCC

Compressors on pallet

 

 

 

 

 

80

 

 

 

Application

 

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

 

HBP

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Evaporating temperature

 

°C

-15 to 20

 

-15 to 15

Voltage range

 

V

198 - 254

 

198 - 254

Max. condensing temperature continuous (short)

°C

 

70 (70)

 

60 (70)

Max. winding temperature continuous (short)

°C

125 (135)

 

125 (135)

Cooling requirements

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Application

 

 

LBP

 

MBP

HBP

 

LBP

MBP

 

HBP

32°C

 

 

 

F2

 

 

F2

38°C

 

 

 

F2

 

 

F2

43°C

 

 

 

F2

 

 

F2

Remarks on application:

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

 

 

CSIR

 

 

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

14.8

 

 

 

 

Cut in Current, HST | LST

 

A

 

14.8

 

 

 

 

Resistance, main | start winding (25°C)

 

5.0

 

 

 

13.7

 

 

Design

 

 

 

 

 

 

 

 

 

 

 

Displacement

 

cm3

 

 

 

10.29

 

 

 

Oil quantity (type)

 

cm3

 

 

500 (polyolester)

 

Maximum refrigerant charge

 

g

 

 

 

1300

 

 

 

Free gas volume in compressor

 

cm3

 

 

 

1410

 

 

 

Weight without electrical equipment

kg

 

 

 

12.2

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

Height

 

mm

A

 

 

209

 

 

 

 

 

 

B

 

 

193

 

 

 

 

 

 

B1

 

 

173

 

 

 

 

 

 

B2

 

 

90

 

 

 

Suction connector

location/I.D. mm | angle

C

 

 

10.2 | 37°

 

 

 

 

material | comment

 

 

Copper | Rubber plug

 

Process connector

location/I.D. mm | angle

D

 

 

6.2 | 37°

 

 

 

 

material | comment

 

 

Copper | Rubber plug

 

Discharge connector

location/I.D. mm | angle

E

 

 

8.2 | 37°

 

 

 

 

material | comment

 

 

Copper | Rubber plug

 

Oil cooler connector

location/I.D. mm | angle

F

 

 

 

 

 

 

 

material | comment

 

 

 

 

 

 

 

Connector tolerance

I.D. mm

 

 

 

±0.09

 

 

 

Remarks:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

 

= Static cooling normally sufficient

O

 

= Oil cooling

F1

 

= Fan cooling 1.5 m/s

 

 

 

(compressor compartment temperature

 

 

 

equal to ambient temperature)

F2

 

= Fan cooling 3.0 m/s necessary

SG

 

= Suction gas cooling normally sufficent

= not applicable in this area

© Danfoss | DCS (CC) | 2017.04

DEHC.ED.200.E5.02 | 1

EN 12900 Household (CECOMAF)

 

220V, 50Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

 

-20

-15

-10

-6.7

 

-5

0

5

7.2

10

15

20

Capacity in W

 

 

 

 

 

 

 

 

 

 

 

233

352

434

 

478

613

762

832

927

1113

1323

Power cons. in W

 

 

 

 

 

 

 

 

 

 

 

235

281

309

 

323

361

395

409

426

453

476

Current cons. in A

 

 

 

 

 

 

 

 

 

 

 

2.34

2.57

2.73

 

2.80

3.03

3.26

3.36

3.48

3.70

3.92

COP in W/W

 

 

 

 

 

 

 

 

 

 

 

0.99

1.25

1.41

 

1.48

1.70

1.93

2.03

2.18

2.46

2.78

EN 12900 Household (CECOMAF)

 

220V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

 

-20

-15

-10

-6.7

 

-5

0

5

7.2

10

15

20

Capacity in W

 

 

 

 

 

 

 

 

 

 

 

318

421

498

 

541

683

849

930

1042

1265

 

Power cons. in W

 

 

 

 

 

 

 

 

 

 

 

287

340

374

 

392

444

496

518

545

593

 

Current cons. in A

 

 

 

 

 

 

 

 

 

 

 

2.13

2.37

2.54

 

2.63

2.90

3.18

3.30

3.46

3.76

 

COP in W/W

 

 

 

 

 

 

 

 

 

 

 

1.11

1.24

1.33

 

1.38

1.54

1.71

1.80

1.91

2.13

 

ASHRAE HBP

 

 

 

 

220V, 50Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

 

-20

-15

-10

-6.7

 

-5

0

5

7.2

10

15

20

Capacity in W

 

 

 

 

 

 

 

 

 

 

 

257

387

477

 

525

675

840

918

1023

1230

1465

Power cons. in W

 

 

 

 

 

 

 

 

 

 

 

235

280

308

 

321

359

393

406

423

449

472

Current cons. in A

 

 

 

 

 

 

 

 

 

 

 

2.34

2.57

2.72

 

2.80

3.02

3.24

3.34

3.46

3.68

3.89

COP in W/W

 

 

 

 

 

 

 

 

 

 

 

1.09

1.38

1.55

 

1.64

1.88

2.14

2.26

2.42

2.74

3.10

ASHRAE HBP

 

 

 

 

220V, 60Hz, fan cooling F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °C

-45

-40

 

-35

-30

-25

-23.3

 

-20

-15

-10

-6.7

 

-5

0

5

7.2

10

15

20

Capacity in W

 

 

 

 

 

 

 

 

 

 

 

354

467

552

 

599

756

939

1029

1153

1400

 

Power cons. in W

 

 

 

 

 

 

 

 

 

 

 

289

340

374

 

391

442

492

514

541

587

 

Current cons. in A

 

 

 

 

 

 

 

 

 

 

 

2.11

2.36

2.52

 

2.61

2.87

3.14

3.26

3.42

3.72

 

COP in W/W

 

 

 

 

 

 

 

 

 

 

 

1.23

1.37

1.48

 

1.53

1.71

1.91

2.00

2.13

2.38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessories for

SC10GH

Figure

Code number

PTC starting device

6.3 mm spade connectors

a1

 

4.8 mm spade connectors

 

 

Starting relay

6.3 mm spade connectors

a2

117U6005

Cover

 

b

103N2008

Start. capacitor 80 µF

6.3 mm spade connectors

c

117U5017

Cord relief

 

d

103N1004

Protection screen for PTC

g

Test conditions

EN 12900/CECOMAF

ASHRAE HBP

Condensing temperature

55°C

55°C

Ambient temperature

32°C

32°C

Suction gas temperature

32°C

32°C

Liquid temperature

55°C

32°C

Mounting accessories

 

 

Code number

Bolt joint for one comp.

Ø: 16

mm

118-1917

Bolt joint in quantities

Ø: 16

mm

118-1918

Snap-on in quantities

Ø: 16

mm

118-1919

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice.This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2 |© Danfoss | DCS (CC) | 2017.04

DEHC.ED.200.E5.02

Loading...