R134a, 220-240V 50/60Hz
General
Code number 104G8000
Approvals EN 60335-2-34
Compressors on pallet 80
Application
Application LBP/HBP LBP/MBP
Frequency Hz 50 60
Evaporating temperature °C -35 to 15 -35 to -5
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C F1F2F2F1F2–
38°C F
43°C F
Remarks on application:
LBP MBP HBP LBP MBP HBP
1F2F2F1F2
1F2F2F1F2
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
–
– = not applicable in this area
–
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 11.1 10.2
Cut in Current, HST | LST A 11.1 14.6
Resistance, main | start winding (25°C) Ω 8.5 14.1
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 1300
Free gas volume in compressor cm
Weight without electrical equipment kg 12.1
Dimensions
Height mm A 199
Suction connector location/I.D. mm | angle C 8.2 | 37°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 6.2 | 37°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:
3
3
3
550 (polyolester)
B 193
B1 173
B2 90
10.29
1510
© Danfoss | DCS (CC) | 2017.04
DEHC.ED.200.E4.02 | 1
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
Danf
already on order pro
All trademarks in this material are property of the respec
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 23 60 113 135 183 268 369 445 486 618 764 833 925 1100
Power cons. in W 93 139 181 195 220 256 290 311 322 353 383 396 412 441
Current cons. in A 1.29 1.34 1.41 1.44 1.50 1.61 1.72 1.8 1.85 1.98 2.12 2.18 2.26 2.40
COP in W/W 0.25 0.43 0.63 0.69 0.83 1.05 1.27 1.43 1.51 1.75 2.00 2.11 2.25 2.49
ASHRAE LBP 220V, 50Hz, fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 29 74 139 166 225 331 456 550 600 764 946 1032 1147 1367
Power cons. in W 93 139 181 195 220 256 290 311 322 353 383 396 412 441
Current cons. in A 1.29 1.34 1.41 1.44 1.50 1.61 1.72 1.8 1.85 1.98 2.12 2.18 2.26 2.40
COP in W/W 0.31 0.53 0.77 0.85 1.02 1.29 1.57 1.80 1.86 2.16 2.47 2.61 2.78 3.10
Accessories for SC10G Figure Code number Test conditions
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors – Ambient temperature 32°C 32°C
a1
103N0011 Condensing temperature 55°C 55°C
EN 12900/CECOMAF
Starting relay 6.3 mm spade connectors a2 117U6002 Suction gas temperature 32°C 32°C
Cover b 103N2009 Liquid temperature 55°C 32°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5017
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC g – Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |© Danfoss | DCS (CC) | 2017.04 DEHC.ED.200.E4.02
ASHRAE LBP