Datasheets
SC10CLX
LBP/MBP Compressor
R404A/R507, 220-240V 50/60Hz
General
Code number 104L2533
Approvals EN 60335-2-34, UL984
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °C -35 to 5 -35 to -5
Voltage range V 198 - 254 198 - 254
Max. condensing temperature continuous (short) °C 50 (60) 50 (60)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C F2F2– F2F2–
38°C F
43°C – – – – – –
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 14.8 –
Cut in Current, HST | LST A 14.8 –
Resistance, main | start winding (25°C) Ω 5.0 13.7
LBP MBP HBP LBP MBP HBP
2F2
– F2F2–
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 1300
Free gas volume in compressor cm
Weight without electrical equipment kg 13.1
Dimensions
Height mm A 209
Suction connector location/I.D. mm | angle C 8.2 | 37°
material | comment Copper | Rubber plug
Process connector location/I.D. mm | angle D 6.2 | 37°
material | comment Copper | Rubber plug
Discharge connector location/I.D. mm | angle E 6.2 | 37°
material | comment Copper | Rubber plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09
Remarks:
3
3
3
550 (polyolester)
B 203
B1 183
B2 100
10.29
1460
© Danfoss | DCS (CC) | 2017.04
DEHC.ED.200.E1.02 | 1
ASHRAE LBP* 230V, 60Hz, fan cooling F
Danf
already on order pro
All trademarks in this material are property of the respec
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 274 399 537 587 690 862 1057 1200 1279
Power cons. in W 312 374 430 449 487 547 617 670 700
Current cons. in A 2.21 2.37 2.55 2.62 2.76 3.00 3.27 3.46 3.57
COP in W/W 0.88 1.07 1.25 1.31 1.42 1.57 1.71 1.79 1.83
ASHRAE LBP* 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 202 306 428 474 571 738 930 1071 1149 1399 1682
Power cons. in W 260 304 353 370 404 455 503 533 548 585 614
Current cons. in A 2.01 2.16 2.32 2.38 2.50 2.70 2.92 3.08 3.16 3.42 3.69
COP in W/W 0.78 1.01 1.21 1.28 1.42 1.62 1.85 2.01 2.10 2.39 2.74
EN 12900 Household (CECOMAF) 230V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 224 335 455 499 588 738 906 1028 1096
Power cons. in W 304 370 430 450 489 552 623 677 707
Current cons. in A 2.19 2.36 2.55 2.62 2.77 3.02 3.30 3.50 3.61
COP in W/W 0.74 0.90 1.06 1.11 1.20 1.34 1.45 1.52 1.55
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 166 255 360 400 483 625 789 910 977 1190 1430
Power cons. in W 258 302 352 369 404 457 508 540 556 597 631
Current cons. in A 2.00 2.15 2.32 2.38 2.51 2.72 2.94 3.10 3.19 3.45 3.73
COP in W/W 0.64 0.84 1.02 1.08 1.20 1.37 1.55 1.68 1.76 1.99 2.27
Accessories for SC10CLX Figure Code number Test conditions
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors – Ambient temperature 32°C 32°C
a1
– Condensing temperature 45°C 43.3°C
EN 12900/CECOMAF
ASHRAE LBP*
Starting relay 6.3 mm spade connectors a2 117U6005 Suction gas temperature 32°C 32°C
Cover b 103N2008 Liquid temperature no subcooling 32°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5017
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC g – Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
vided that such alterations can be made without subsequential changes being necessary eady agreed.
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |© Danfoss | DCS (CC) | 2017.04 DEHC.ED.200.E1.02