Danfoss RT 260A, RT 262A, RT 265A, RT 260AL, RT 262AL Installation guide [da]

...
Installation guide
Differential pressure switch
RT 260A, RT 262A, RT 265A, RT 260AL, RT 262AL, RT 263AL, RT 266AL
Refrigerants*): R22, R134a, R404A, R407A, R407C, R407F, R422B, R422D, R507A, R717
017R9506
RT 260 A RT 262 AL
Fig. 1 Fig. 2
017R9506
s
Fig. 3 Fig. 4
Fig. 5 Fig. 6
Fig. 7 Fig. 8 Fig. 9
© Danfoss | DCS (rm) | 2019.09
DKRCC.PI.CE0.B2.53 | 520H11632 | 1
ENGLISH
Differential pressure switches
*) For complete list of approved refrigerants, www.products.danfoss.com and search for
individual code numbers, where refrigerants
are listed as part of technical data.
Technical data
Differential
Typ e
RT 260A
RT 260A
RT 260A
RT 262A
RT 265A
RT 260AL
RT 262AL
RT 263AL
RT 266AL
pressure
range p
1.5 – 11 -1 – 31 0.5 42
0.1 – 1. 5 -1 – 9 0.1 11
0.1 – 1. 5 -1 – 9 0.1 11
0.1 – 1. 0 -1 – 6 0.05 7
Neutral zone, p Nz RT 260AL: 0.3 bar – 0.9 bar RT 262AL: 0.1 bar – 0.33 bar RT 263AL: 0.05 bar – 0.23 bar RT 266AL: 0.05 bar – 0.23 bar
Max. test pressure, p' = 1.1 × MWP Permissible temperature range: -40 °C – 70 °C
Contact load
See contact cover or fig. 3. If the contact load is given as, for example, 10 (4) A, 400 V AC, it means that the connected load must be max. 10 A ohmic and 4 A inductive at 400 V AC. The permissible starting current on motor cut-in can be up to seven times the inductive load, but max. 28 A. The switch meets the requirements of VDE* 0660.
*VDE = Verband Deutscher Elektrotechniker
Installation
A set of Pg13.5 cable gland is attached to the RT in a separate bag. To ensure IP66 (units with automatic reset) or IP54 (units with external reset) grade of RT enclosure it is necessary to assemble this gland as shown in the fig. 4. If this gland is not used with a cable, a metal blinding should be also assembled.
The differential pressure control must be mounted on a valve panel or, for example, direct on a compressor. Use the fixing holes (25). If the unit can be exposed to vibration, it should to be mounted on a resilient pad.
Product must be always mounted vertically with the LP side placed on the top and the HP side placed on the bottom (as shown in the fig. 1).
Electrical connection
See fig. 5. START = make. STOP = break DIFF = fixed contact differential Cable diameter: 6 – 14 mm Connect earth to the earth screw (38)
Setting
Set the required differential pressure with the setting disc (5) while at the same time reading the scale (9). Find the required neutral zone for RT 260AL, RT 262AL, RT 263AL, RT 266AL from the diagram. The setting value for the
Operation
LP bellows
[bar]
0.5 – 4 -1 – 18 0.3 22
0.5 – 6 -1 – 36 0.5 42
1 – 6 -1 – 36 0.5 42
0.5 – 4 -1 – 18 0. 3 22
0 – 0.9 -1 – 6 0.05 7
range for
[bar]
Mechani-
cal
differen-
tial
[bar]
Max. working pressure
MWP
[bar]
neutral zone (40) can be read from the lowest scale on the diagram.
Example 1
RT 262A with terminals 1 – 4 connected. Set differential pressure p = 0.5 bar. The RT 262A breaks at a differential pressure of 0.5 bar and makes at a differential pressure + contact differential = 0.5 bar + 0.1 bar = 0.6 bar.
Example 2
RT 262AL Required differential pressure p = 0.5 bar. Required neutral zone Nz = 0.25 bar. As can be seen on the diagram, fig. 6., the required neutral zone of 0.25 bar is obtained by setting the neutral zone disc (40) at 2.5. Because the contact differential is 0.1 bar, the make and break differential pressures for the switch are:
Make differential pressure for contacts 1 – 4 = 0.5 bar + 0.1 bar = 0.6 bar. Break differential pressure for contacts 1 – 4 = 0.5 bar (= set value p). Make differential pressure for contacts 1 – 2 = 0.6 bar – 0.25 bar = 0.35 bar. Break differential pressure for contacts 1 – 2 = 0.35 bar + 0.1 bar = 0.45 bar.
DANSK
Differenspressostater
*)
For komplet liste over godkendte kølemidler,
besøge www.products.
efter individuelle bestillingsnumre, hvor kølemidler er opført som en del af tekniske data.
Tekniske data
Differens-
Typ e
RT 260A
RT 260A
RT 260A
RT 262A
RT 265A
RT 260AL
RT 262AL
RT 263AL
RT 266AL
trykområde
p
[bar]
0.5 – 4 -1 – 18 0. 3 22
0.5 – 6 -1 – 36 0.5 42
1.5 – 11 -1 – 31 0.5 42
0.1 – 1. 5 -1 – 9 0.1 11
1 – 6 -1 – 36 0.5 42
0.5 – 4 -1 – 18 0. 3 22
0.1 – 1. 5 -1 – 9 0.1 11
0.1 – 1. 0 -1 – 6 0.05 7
0 – 0.9 -1 – 6 0.05 7
Neutralzone, p Nz RT 260AL: 0.3 bar – 0.9 bar RT 262AL: 0.1 bar – 0.33 bar RT 263AL: 0.05 bar – 0.23 bar RT 266AL: 0.05 bar – 0.23 bar
Maks. prøvetryk, p' = 1.1 × PB Tilladelig temperatur: -40 °C – 70 °C
Kontaktbelastning
Se kontaktdæksel eller fig. 3. Er kontaktbelastningen eksempelvis angivet som 10 (4) A, 400 V AC betyder det, at der maks. må tilsluttes 10 A ohmsk og 4 A induktiv belastning ved 400 V AC Maksimal startstrøm ved indkobling af motor må være op til syv gange den induktive belastning – dog maks. 28 A. Kontaktsystemet opfylder betingelserne i
*VDE = Verband Deutscher Elektrotechniker
danfoss.com og søg
Driftsom-
råde for
LP-bælg
[bar]
Mekanisk
differens
[bar]
ladeligt
drifts-
tryk PB
[bar]
Til-
Montering
Et sæt Pg13,5 kabelforskruning er vedlagt produktet i en separat pose. For at sikre kapslingsgrad IP66 (enheder med automatisk reset) eller IP54 (enheder med ekstern DANSK RESET) er det nødvendigt at montere denne kabelforskruning som vist i fig. 4. Hvis denne kabelforskruning ikke bruges sammen med et kabel, bør der monteres en blindprop (metal skive).
Differenspressostaten monteres på en ventilt­avle eller f.eks. direkte på en kompressor. Benyt monteringshullerne (25). Hvis apparatet kan blive udsat for vibrationer, bør det monteres på et blødt underlag.
Produktet skal altid monteres lodret med LP-siden placeret øverst og HP-siden nederst (som vist i fig. 1).
El-tilslutning
Se fig. 5. START = slutte. STOP = bryde DIFF = fast kontaktdifferens. Kabeldiameter: 6 – 14 mm. Jordforbindelse tilsluttes jordskruen (38).
Indstilling
Det ønskede differenstryk indstilles ved hjælp af indstillingsskiven (5) under samtidig aflæsning af skalaen (9). Den ønskede neutralzone for RT 260AL, RT 262AL, RT 263AL, RT 266AL opsøges i diagrammet. På diagrammets nederste skala aflæses den værdi, neutralzonerullen (40) skal indstilles på.
Eksempel 1
RT 262A med klemme 1 – 4 tilsluttet.Indstillet differenstryk p = 0.5 bar. RT 262A bryder ved differenstrykket
0.5 bar og slutter ved differenstrykket + kontaktdifferensen = 0.5 bar + 0.1 bar = 0.6 bar.
Eksempel 2
RT 262AL Ønsket differenstryk p = 0.5 bar. Ønsket neutralzone Nz = 0.25 bar. Som det kan ses af diagrammet fig. 5., opnås den ønskede neutralzone på 0.25 bar ved at indstille neutralzonerullen (40) på værdien 2.5. Slutte- og brydedifferenstrykkene for kontaktsystemet (se fig. 4.) bliver herved, idet kontaktdifferensen er 0.1 bar:
Sluttedifferenstryk for kontakterne 1 – 4 = 0.5 bar + 0.1 bar = 0.6 bar. Brydedifferenstryk for kontakterne 1 – 4 = 0.5 bar (= indstillingsværdi, p). Sluttedifferenstryk for kontakterne 1 – 2 = 0.6 bar – 0.25 bar = 0.35 bar. Brydedifferenstryk for kontakterne 1 – 2 = 0.35 bar + 0.1 bar = 0.45 bar.
2 | 520H11632 | DKRCC.PI.CE0.B2.53