Danfoss Remote LCP Fact sheet

Fact sheet | Remote LCP holder

Remote LCP – easily operate and program your drive at a distance

EASY

LCP access no matter the location

Easy access no matter the location

AC drives are often mounted in places with limited access: inside a panel or a machine, just under the roof or in a cellar. But with the Remote LCP holder, you can easily access your drives no matter where they are located.

The Remote LCP holder is designed for outdoor installations and is ideal for many applications, for instance roof top units (RTU) or in water pump applications where the drive and pump are mounted in an underground chamber and the Remote LCP holder above ground.

Full overview of your drive

The solution is designed with userfriendliness at its core. Open the cover for full access to the LCP and get optimal readability even in heavy sunlight.

The closed cover ensures proper protection of the LCP and visibility to warning and fault notifications from the LED lights.

Use a padlock with the Remote LCP holder cover to ensure that only authorized persons read out and operate the drive.

Designed for insulated airhandling units

The Remote LCP holder is specifically engineered for insulated air-handling units (AHUs) and RTUs, as the wall tap fits with the standard wall insulation of an AHU including accessories to seal the solution.

Easy installation

Easily install the Remote LCP holder including drive adapter and

interconnection cable, as all parts are prepared for installation. Simply drill a hole for the wall tap and fasten the Remote LCP holder using screws. Remove the LCP from the drive and mount it onto the LCP holder. Join the interconnection cable with its preassembled M12 connectors.

The Remote LCP holder can also be used with a wireless LCP, thereby improving the wireless transmission.

Features

Remote mounting kit

LCP cover with padlock hole

Built for outdoor applications

Wall tap with gasket & nut

Cost-competitive solution

Benefits

Position of LCP to optimize usability of the user interface.

Position of wireless LCP to optimize wireless connection.

Place the drive inside an air-handling unit or control panel to protect the drive, or in areas with limited access.

LCP protection against heavy weather conditions.

The cover aids readability in sunlight.

Protection against unauthorized operation of the drive, monitoring operation values and changing of parameters.

High IP rating and materials suited for outdoor applications.

Drive adapter with gasket to retain the IP rating of the drive.

No corrosion risk as the LCP holder has no metal parts.

Especially for air-handling units with insulated walls, where the gasket prevents air leakage or moisture to enter the AHU.

Easy installation with pre-assembled interconnection cable and reuse of LCP from the drive.

Material selection for a cost-competitive solution that fits outdoor applications.

drives.danfoss.com

Danfoss Remote LCP Fact sheet

Specifications

Ordering number

Compatibility

Package includes

LCP protection cover

Interconnection cable

Special adapter

Holder dimensions

Wall-mounting connection

Environment

134B5223 – Kit with 3 m/10 feet cable

134B5224 – Kit with 5 m/16 feet cable

134B5225 – Kit with 10 m/33 feet cable

VLT® HVAC Drive FC 102

VLT® Refrigeration Drive FC 103

VLT® AQUA Drive FC 202

VLT® Automation Drive FC 301/FC 302

VLT® Lift Drive LD 302

LCP holder with D-sub connector for the LCP and a wall tap with M12 male connector for interconnection cable.

LCP cover protecting the LCP or wireless transmitter against sunlight etc.

Drive interface adapter, for interconnection cable and IP gasket to obtain the approved IP rating.

IP66 interconnection cable with M12 connectors.

A mounting nut and gasket to shield the baseplate holder to the wall.

Disassembly tool to remove front cover.

LCP or wireless transmitter is not included but is to be moved from the drive to the remote holder.

Notifications from LED lights indicating if the drive is on, or if there are warnings or alarms – visible at a 45° angle.

5 mm / 0.039 inch padlock hole.

Color: Black & light grey

Plastic material.

Two M12 connectors, a 90° male connector for the drive adapter and a straight female connector at the cradle.

IP55/66 drives delivered without LCP mounted from factory need a special cradle adaptor to attach the LCP or wireless LCP to the drive –

spare part no 130B0264.

Front cover

Size (length*width*height). 164.5*95.5*38 mm / 6.5*3.8*1.5 inches.

Padlock adds 8 mm / 0.3 inch to the height.

Wall tap

Size 104 mm & 18 mm / 4.1 inches & 0.71 inch (length & diameter).

Wall thickness of 0-90 mm (0–3.55 inches).

Uses the air seal of the nut.

A 24 mm / 0.95-inch hole for the connection tap.

4*4 mm screws for securing the baseplate mounting (not included).

Nut to secure a tight seal to the connection tap.

Enclosure rating

 

IP54 of the LCP holder and IP20/21/54/55/66 for the drive adapter,

 

IP66 for the interconnection cable.

 

 

Temperature range

 

-25 to +50 °C

Approvals

 

 

Vibration

 

EN50178 & IEC721-3-3 class 3M3

 

General

 

IEC/EN61800-2

DKDD.PFM.103.A1.02

© Copyright Danfoss Drives | 2021.08

Loading...