Valve Bodies Type RA-UN and RA-UR with Delta
Gland Seal
Application
RA-UN, StraightAngleUK-angleRA-UR
All RA-UN/UR valve bodies can be used together
with all types of thermostatic elements in the RA
2000 series.
The valve bodies are fitted with a kv limiting
device for pre-setting of max. water flow.
RA-UN is for mounting in the flow and RA-UR in
the return. An arrow on the valve body indicates
the direction of flow.
The valve body RA-UN/RA-UR is used in two-pipe
heating systems and is available with the
following setting ranges for max. water flow:
RA-UN
RA-URkv = 0.02 - 0.47 m³/h
The valve bodies are supplied with a protective
cap and adjusting screw which can be used for
manual regulation during the construction
phase.
kv = 0.02 - 0.48 m³/h
The protective cap must not be used as a manual
shut off device. A special manual shut off device
(code no. 013G5000) should be used.
To be able to distinguish between other valve
bodies of the RA 2000 series the protective cap is
yellow.
Compression fittings for 15 mm, 10 mm or 8 mm
copper tube are available for valve body RA-UN/
UR with 3/8" and 1/2" BSP connections.
Valve bodies are manufactured from brass with
nickel plating. The pressure pin of the gland seal
is of chrominium steel and works in a lifetime
lubricated O-ring. The complete gland assembly
can be replaced without draining down the
system.
Should water treatment be used it is essential
that dosing instructions of the manufacturer are
strictly observed. It is recommended that
formulations containing mineral oil are avoided.
All Danfoss RA 2000 radiator thermostats
are manufactured to the highest standards,
and are approved to the European
standard EN 215 and dimension standard
HD 1215-2, which superseeds BS 6284 1983.
All Danfoss radiator thermostats are
manufactured in factories, assessed and certified
by BSI against BS 5750 (ISO 9000).
Data SheetValve Bodies Type RA-UN and RA-UR with Delta Gland Seal
Data SheetValve Bodies Type RA-UN and RA-UR with Delta Gland Seal
1)
Working pressure = static + differential pressure. The maximum differential pressure specified is the
maximum pressure at which the valves give satisfactory regulation. As with any device which imposes
a pressure drop in the system, noise may occur under certain flow/pressure conditions. To ensure quiet
operation, maximum pressure drop should not exceed 30 to 35 kPa. The differential pressure can be
reduced by the use of the Danfoss differential pressure regulators.
2)
The kv-value indicates the water flow (Q) in m³/h at a pressure drop (∆p) across the valve of 1 bar;
. At setting N the kv-value is stated according to EN 215, at XP = 2K i.e. the valve is closed at 2°C
higher room temperature. At lower settings the XP-value is reduced to 0.5K of the setting value 1. The
kvs-value states the flow Q at a maximum lift, i.e. at fully open valve at setting N. When using remote
setting adjusters or RAE sensors kv-values are reduced for identical P-band
Accessories
Setting
ProductDimensionFor valve bodyCode no.
Delta sealAll RA valves013G0297
Compression fittings for steel and copper tubes, incl.
compression ring and nipple
Rp 3/8 x Ø 10
Rp 3/8 x Ø 12013G4102
RA-UN/RA-UR 10
Rp 1/2 x Ø 10
Rp 1/2 x Ø 12013G4112
RA-UN/RA-UR 15
013G4100
013G4110
Rp 1/2 x Ø 15013G4115
Accessories are sold in boxes of 10.
Presetting area
Operating Principle
1. Gland seal
2. O-Ring
3. Pressure pin
4. Seal
5. Regulation spring
6. Setting dial
7. Valve body
8. kv-nozzle
The radiator thermostats consist of a
thermostatic element of the RA 2000 series and a
The element and the valve body are ordered
separately.
Data SheetValve Bodies Type RA-UN and RA-UR with Delta Gland Seal
UK-angle valve body with thermostatic sensor RA
2990
Type
RA-UN 10
RA-UN 10 UK
RA-UN 15
RA-UN 15 UK
RA-UN 20
RA-UR 10
RA-UR 10 UK
RA-UR 15
D
Rp 3/8
Rp 3/8
Rp 1/2
Rp 1/2
Rp 3/4
Rp 3/8
Rp 3/8
Rp 1/2
d
2
ISO 7-1S1S2
L1L2L3L4L5L6L7L8L9L
10
R 3/8608527 52 22 47962227
R 3/859 10826 51222227
R 1/2679530 58 26 47962730
R 1/260 10929 57272730
R 3/474 10634 66 29 47963237
R 3/8608528 53 22 47962227
R 3/8479628 53272227
R 1/2679528 53 27 47962227
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective
companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.