Danfoss RA-N Installation guide [uk]

Instruction
Installing RA-N radiator valvesand RLV lockshield valves
with press-t connection
1. Ensure that the tools needed are available.
3. Install the nipple.
The RA-N radiator valve
must be installed in the ow line. Make sure that the surface for the O-ring is intact, or use Teon or similar sealing material.
5. Cut the pipes using a pipe cut­ter.
Cutting tools that leaves burs
on the pipe end are not recom­mended.
2. Ensure that the workspace is sucient, according to press tools suppliers specications.
4. Install the nipple.
The RLV lockshield valve
must be installed in the return line. Make sure that the surface for the O-ring is intact, or use Teon or similar sealing material.
6. Debur the pipe ends.
7. Visually inspect that the O-ring is placed correctly in the inside groove of the press-t part of the valve.
9. Place the press jaw centered on the press-t part of the valve.
11. Adjust the presetting of the
valve.
8. Insert the pipe 22 mm into the valve and mark it.
10. Visually inspect the marking
to ensure that the pipe is not squeezed out of the valve during the pressing.
12. Install the sensor.
DKCD VISXA202 © Danfoss 05/2009