Danfoss PVPX Installation guide

Danfoss PVPX Installation guide

Installation Guide

LS pressure relief valve for PVG32

Type PVPX

Across flats

 

 

Max. Tightening torque

 

24 mm [0.94 in]

 

 

45 Nm [400 lbf•in]

 

 

 

 

 

 

 

 

 

 

 

 

Max operation pressure

 

350 bar [5075 psi]

 

 

 

 

 

 

 

Max. coil surface temperature

155°C [302°F]

 

 

 

 

 

 

 

 

 

Rated voltage

 

12 V

 

24 V

26 V

 

 

 

 

 

 

Current consumtion

22°C coil temperature

1.22 A

 

0.67 A

0.87 A

 

 

 

 

 

 

 

110°C coil temperature

1 A

 

0.5 A

0.5 A

 

 

 

 

 

 

 

22°C coil temperature

19 W

 

19 W

19 W

 

 

 

 

 

 

 

110°C coil temperature

12 W

 

12 W

12 W

 

 

 

 

 

 

Max. permissble deviation from rated supply voltage

±10%

 

 

 

 

 

 

 

 

 

© Danfoss | June 2017

AN00000059en-US0303 | 1

Connection

When installing the wire remember to connect the built-in diode to the plug pins.

AMP plug connection

157-413.10

The AMP plug contains no integrated diode. PVPX control curcuit protection must thus be installed externally, possible by means of a (36V suppressor diode, BZW04) in the terminal block.

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2 | © Danfoss | June 2017

AN00000059en-US0303