Installation Guide
LS pressure relief valve for PVG32
Type PVPX
Across flats Max. Tightening torque
24 mm [0.94 in] 45 Nm [400 lbf•in]
Max operation pressure 350 bar [5075 psi]
Max. coil surface temperature 155°C [302°F]
Rated voltage 12 V 24 V 26 V
Current consumtion 22°C coil temperature 1.22 A 0.67 A 0.87 A
110°C coil temperature 1 A 0.5 A 0.5 A
22°C coil temperature 19 W 19 W 19 W
110°C coil temperature 12 W 12 W 12 W
Max. permissble deviation from rated supply voltage ±10%
©
Danfoss | June 2017 AN00000059en-US0303 | 1
Connection
When installing the wire remember to connect the built-in
diode to the plug pins.
AMP plug connection
The AMP plug contains no integrated diode. PVPX control
curcuit protection must thus be installed externally, possible by
means of a (36V suppressor diode, BZW04) in the terminal
block.
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 | © Danfoss | June 2017 AN00000059en-US0303