Danfoss is able to supply pump side modules type PVPV and PVPVM for systems with variable pumps.
The modules offer the following advantages:
P- and T-connection ports: 1" [1 5/16 UN]
•
Lower pressure drop
•
PVPVM enables the use of LS-pumps with flows up to 230 l/min [61 US gal/min]
•
Relief of pressure peaks with PVLP 63
•
Versions and code numbers
SymbolDescriptionCode number
BSP port
P, T = G1
PVPV
Closed center pump side module for pumps
with variable displacement
With pilot supply for electrical actuation
Max. pump pressure = 350 bar [5075 psi]
Max. pump flow = 150 l/min [40 US gal/min]
157B5938157B5911
SAE port
1 5/16 UN
PVPV
Closed center pump side module for pumps
with variable displacement
With pilot supply for electrical actuation
With shock and suction valve PVLP 63
Max. pump pressure = 350 bar [5075 psi]
Max. pump flow = 150 l/min [40 US gal/min]
PVPVM
Closed center pump side module for pumps
with variable displacement
With pilot supply for electrical actuation
Max. pump pressure = 350 bar [5075 psi]
Max. pump flow = 230 l/min [61 US gal/min]
PVPVM
Closed center pump side module for pumps
with variable displacement
With pilot supply for electrical actuation
With shock and suction valve PVLP 63
Max. pump pressure = 350 bar [5075 psi]
Max. pump flow = 230 l/min [61 US gal/min]
157B5941157B5913
157B5937157B5912
157B5940157B5914
PVPV hydraulic schematic
When ordering PVPV fitted with PVLP 63, please state the sales- and code No. in space 0 in the order
form. Always state the PVLP 63 opening pressure in space 0, see the PVG 32 specification sheet.or the
literature PVG 32 Specification Sheet, 520L0515. See example:
4520L0222 • Rev EF • May 2014
Technical Information
Introduction
PVPV, PVPVM • Pump Side Modules for Variable Displacement Pumps
Example:Code number
0 157B 5941
p = 100 bar [1450 psi]157B –
157B2100
PVPV hydraulic schematic
PVPVM hydraulic schematic
To order PVG 32 fitted with PVPVM, use standard order form, see the PVG 32 specification sheet or the
literature PVG 32 Specification Sheet, 520L0515. When ordering PVPVM fitted with PVLP 63, please state
the sales- and code No. in space b in the order form. Also, always state the PVLP 63 opening pressure in
space 0.
520L0222 • Rev EF • May 20145
Technical Information
Introduction
PVPV, PVPVM • Pump Side Modules for Variable Displacement Pumps
PVPVM hydraulic schematic
Flow characteristics for PVPV/PVPVM
Flow from PVB (without pressure compensator) left and right of PVPVM respectively.
Under certain circumstances systems with large pump flows may occasionally generate pressure peaks.
For advice on systems of this nature, please contact the Danfoss Sales Organisation.
6520L0222 • Rev EF • May 2014
Technical Information
Introduction
PVPV, PVPVM • Pump Side Modules for Variable Displacement Pumps
Set pressure difference between pump pressure and LS signal = 10 bar [145 psi]
Set pressure difference between pump pressure and LS signal = 15 bar [218 psi]
The oil flow depends on the pressure difference between pump pressure and LS-signal. Normally, the
pressure difference can be set on the LS-pump control.
520L0222 • Rev EF • May 20147
V310124.B
Technical InformationPVPV, PVPVM • Pump Side Modules for Variable Displacement Pumps
Introduction
PVPVM dimensions
MA, LS : G¼ [9/16 - 18 UNF]
Stay bolt set, PVAS for PVPVM
In PVG 32 valve groups fitted with PVPV use standard PVAS, 157B8001 → 8010.
For pump pressures over 320 bar [4641 psi], use stay bolt set 157B8041 → 8050.
Technical InformationPVPV, PVPVM • Pump Side Modules for Variable Displacement Pumps
Introduction
PVG 32 specification sheet
10520L0222 • Rev EF • May 2014
Technical InformationPVPV, PVPVM • Pump Side Modules for Variable Displacement Pumps
520L0222 • Rev EF • May 201411
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electronic components. We specialize in providing state-of-the-art technology and solutions that
excel in the harsh operating conditions of the mobile off -highway market. Building on our extensive
applications expertise, we work closely with our customers to ensure exceptional performance for a
broad range of off -highway vehicles.
We help OEMs around the world speed up system development, reduce costs and bring vehicles to
market faster.
Danfoss – Your Strongest Partner in Mobile Hydraulics.
Go to www.powersolutions.danfoss.com for further product information.
Wherever off -highway vehicles are at work, so is Danfoss.
We off er expert worldwide support for our customers, ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also provide
comprehensive global service for all of our components.
Please contact the Danfoss Power Solution representative nearest you.
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions
(Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 3418 5200
Products we off er:
• Bent Axis Motors
• Closed Circuit Axial Piston
Pumps and Motors
• Displays
• Electrohydraulic Power
Steering
• Electrohydraulics
• Hydraulic Power Steering
• Integrated Systems
• Joysticks and Control
Handles
• Microcontrollers and
Software
• Open Circuit Axial Piston
Pumps
• Orbital Motors
• PLUS+1® GUIDE
• Proportional Valves
• Sensors
• Steering
• Transit Mixer Drives
Comatrol
www.comatrol.com
Schwarzmüller-Inverter
www.schwarzmuellerinverter.com
Turolla
www.turollaocg.com
Valmova
www.valmova.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Local address:
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without changes being necessary in specifications already agreed..
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.