Danfoss PVP OC, PVP CC Data sheet

Data Sheet
Module
PVP OC/CC
The PVG 32 inlet program now offers an inlet module with selectable Open Center/Closed Center configuration in same module.
The module directs itself to application with a PVG valve fitted but where the pump type is not determined by the machine builder. A typical application could be an agricultural attachment.
The pump type will be determined by the tractor pulling the attachment and the valve inlet can easily be changed to fit the pump.
For systems with LS leak/bleed-off and long LS lines the module is also available with an unique integrated LS boost functionality to ensure fast and prompt reaction.
Features
Maximum system pressure relief setting
Integrated pressure matching spool
Integrated pilot oil pressure supply for PVE
Possibility to switch from Open Center to Closed Center or vice versa externally on application using hex key
Possibility for integrated LS boost to compensate for LS bleed-off and leakage
Versions available:
Code number Thread LS
compensation
11119094 BSP No For PVE 11119095 UNF No For PVE 11093273 BSP Yes For PVE 11131344 BSP Yes For PVH
Comprehensive technical literature online at powersolutions.danfoss.com
Pilot supply
©
Danfoss | Jun 2016 L1209890 | AI00000144en-US0202 | 1
Technical Data
P005 700 E
OC/CC
P
T
6 bar spring
LS
M
21 [0.827] max.
18 [0.709] min.
10 [0.394] max.
Ø6.25 max.
[Dia 0.246
]
M4
118° ±5°
118° ±5
°
Maximum pressure P-port continuous 350 bar [5075 psi]
P-port intermittent 400 bar [5800 psi] T-port static/dynamic 25/40 bar [365/580 psi]
Oil flow rated P-port 140 l/min [37 US gal/
min]
OC/CC selector
Changed using a 6 mm hexagonal key.
Turned clockwise (screw in) equals Open Center configuration. The oil then flows from the pump through the P-port in the PVP OC/CC module across the main spool to tank. The oil led across the pressure adjustment spool determines he pump pressure. When one or more sections in the valve stack is being actuated, the highest load pressure is fed to the spring chamber behind the pressure adjustment spool and completely or partially closes the connection to tank.
Turned counter-clockwise (screw out) equals Closed Center configuration. The oil still enter though the P-port in the PVP OC/CC module but the pressure adjustment spool will only open to tank when the P-channel pressure exceeds the setting of the pressure relief valve. The LS signal is led to the pump regulator through the LS-port connection.
LS boost
The LS to the pump regulator can be increased by using an integrated LS boost. The LS signal comming out of the plug will then be 6 bar higher than the actual LS pressure in the valve stack.
Schematic
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 | © Danfoss | Jun 2016 L1209890 | AI00000144en-US0202