Danfoss PVG32/ECO80 Data sheet

11202147
LS
T0
Pp
Pp
P T
PVG32/16 Side ECO80 Side
Data Sheet
EVGI
PVG32/ECO80 Interface
The EVGI Interface enhances ECO80LS with PVG32 and PVG16 performance features.
The EVGI, PVG32/ECO80 Interface combines PVG 32, PVG16 and ECO 80 into a single valve group. (Both PVG32 and ECO80LS assembly kits fasten into the EVGI module) (Compatible with T0 or non-T0 PVG32 modules.)
Benefits
Increased fixed and variable pump flow capacity from PVG32 standard and mid-inlet
Increased safety disabling downstream ECO80LS functions using PVSKM
Prioritization of downstream ECO80LS functions using PVSPM
Features
Independent Pilot Pressure Reducing Valve for ECO80 EVHC / EVHCO actuation
Designed to align to single mounting surface
Interface hydraulic schematic
Part numbers interface
Description Part number
EVGI-INTERFACE-ECO80LS-PPRV-A 11202147
Comprehensive technical literature is online at www.danfoss.com
©
Danfoss | November 2019 AI324384047850en-000101 | 1
LS
T
P
M
A
B
B
LS
A
LS
A
B
B
LS
A
LS
BAB
A
B
A
B
A
LS
T0
Pp
Data Sheet
EVGI PVG32 ECO80 Interface
Operating conditions
Pump Pressure Maximum 280 bar Tank pressure (bar) Static 25 bar
Dynamic 40 bar
Pilot Pressure at ECO side Maximum 28 bar Oil temperature (°C) Recommended 30 60 °C
Minimum -30 °C Maximum 90 °C
Ambient temperature Minimum -30 °C
Maximum 60 °C
Oil viscosity Operating range 12 - 75 mm2/s
Minimum viscosity 4 mm2/s Maximum viscosity 460 mm2/s
PVG32/ECO80 Hydraulic Schematic
PVG32/ECO80 3D view
2 | © Danfoss | November 2019 AI324384047850en-000101