Danfoss Proportional Valve Data sheet

Data Sheet
Proportional Valve
PVX
With the introduction of our new PVX proportional valve, Danfoss introduces an industry-changing advancement in valve technology for off-highway applications.
The PVX valve features a robust 2-spool hydraulic design with integrated software and sensors that enable intelligent valve configuration and superior control.
To provide maximum system design flexibility, the PVX is designed as a sectional valve, supporting up to 12 functions.
Features
Main characteristics
Max work port pressure 420 bar [6090 psi]
Max Tank pressure 70 bar [1015 psi]
Inlet flow rated 240 l/min [63.4 US gal]
Oil port flow rated 180 l/min [47.5 US gal]
Inlet options
LS pump control (PXP-CC)
BSP threads (P and T 1”)
Work section options
BSP threads (A and B ¾”, LS ¼”)
Single spool work section (PXBM)
Two spool work section (PXBH)
Zero leakage ports as an option (PXBZH)
Integrated port pressure and temperature sensors
Integrated spool position feedback
Regenerative spool option
Float spool option
Software controlled options
CAN communication interface
J1939
CANOpen
Enhanced on-board diagnostics
Configurable margin pressure
Flow-sharing with priority level as an option
Active dampening feature
Selectable operation mode
Configurable spool functionalities
Progressivity, A/B port flow
Individual LS A/B pressure limiting feature
Meter-in/meter-out feature
Setup and Diagnostisc
PLUS+1® Compliant
User-friendly application for easy configuration and diagnostics
Comprehensive technical literature online at powersolutions.danfoss.com
©
Danfoss | Jul 2016 L1326616 | AI00000180en-US0202 | 1
Pictorial Cross-section Views
P T
PXP
PXBM
PXBH
PXBZH
LS
A B A BBA
I
P
I
P
P
I
P
I
P
I
P
I
I
P
P
I
Hydraulic Schematic
Operation modes
Operational mode Available in PXBM
modules
1 - Meter-in Yes Yes Adjustable back pressure 2 - Meter-out Yes Yes Adjustable feed pressure 3 - Pressure control No Yes 5 - Flow in/out A port Yes Yes Pressure control on B port 6 - Flow in/out B port Yes Yes Pressure control on A port 7 - Flow in/out A port (only one port connected) Yes Yes 8 - Flow in/out B port (only one port connected) Yes Yes 11 - Continuous Regen No Yes 13 - Load detection Regen No Yes 15 - Seperate metering (SmartMetering) No Yes
Available in PXBH modules
Added feature when PXBH modules
Each work section can be individually configured to optimize controllability and performance.
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 | © Danfoss | Jul 2016 L1326616 | AI00000180en-US0202