Proportional Valves Technical Information
Flow Control, Pressure Compensated, Priority Type, Normally Open
PFC10-PO
|
|
THEORETICAL PERFORMANCE |
OPERATION |
This is a pressure-compensated, priority-type, normally- |
|
|
open, spool-type, proportional flow-control. Controlled |
|
|
flow is from port 1 to 3, port 2 is bypass. |
|
SPECIFICATIONS |
Rated pressure |
260 bar [3770 psi] |
|
||
|
Maximum flow at |
PFC10-PO-10: 10 l/min [2.64 US gal/min] |
|
rated pressure |
PFC10-PO-25: 25 l/min [6.6 US gal/min] |
|
Leakage |
PFC10-PO-35: 35 l/min [9.25 US gal/min] |
|
420 cm³/min [25.6 in³/min] @ |
|
|
Weight including |
rated pressure |
|
0.72 kg [1.59 lb] |
|
|
coil |
|
|
Hysteresis |
8% maximum |
|
Threshold current |
0.1 A (12 VDC coil) |
|
Maximum control |
0.05 A (24 VDC coil) |
|
1.8 A (12 VDC coil) |
|
|
current |
0.9 A (24 VDC coil) |
|
Cavity |
SDC10-3 |
|
Standard Coil |
M19P 22 Watt |
SCHEMATIC
DIMENSIONS |
|
mm [in] |
Cross-sectional view |
ORDERING
INFORMATION
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BC332375973113en-000101 • February 2020 |
|
|
|
|
|
|
|
|
PV - 50 |