Proportional Valves Technical Information
Flow Control, Pressure Compensated, Priority Type, Normally Closed
PFC10-PC
OPERATION
SPECIFICATIONS
This is a pressure-compensated, priority-type,
normally-closed, spool-type, proportional flowcontrol. Controlled flow is from port 1 to 3, port
2 is bypass.
Rated pressure 260 bar [3770 psi]
Maximum flow at
rated pressure
Leakage 420 cm³/min [25.6 in³/min] @
Weight including
coil
Hysteresis 8% maximum
Threshold current 0.36 A (12 VDC coil)
Maximum control
current
Cavity SDC10-3
Standard Coil M19P 22 Watt
PFC10-PC-10: 10 l/min
[2.64 US gal/min]
PFC10-PC-25: 25 l/min
[6.6 US gal/min]
PFC10-PC-40: 40 l/min
[10.6 US gal/min]
rated pressure
0.62 kg [1.37 lb]
0.18 A (24 VDC coil)
1.8 A (12 VDC coil)
0.9 A (24 VDC coil)
SCHEMATIC
THEORETICAL PERFORMANCE
DIMENSIONS
mm [in]
ORDERING
INFORMATION
Cross-sectional view
BC332375973113en-000101 • February 2020