Danfoss OP-LPOM120LL Data sheet

Condensing unit Model :
OP-LPOM120LL
Condensing Unit Code
:
114X3485
Housing :
H4
LLZ024T4
Electrical code :
E
2
Document No :
118A1983
A
63 125 250 500 1000 2000 4000 8000 16k
L
WA
OP-LPOM120LL
1/1 Octave dBA 63 67 69 71 70 70 79 59 43 81
1m 3m 10m
70 61 50
Acoustic spectrum data are calculated by addition of sound power levels of compressor and fan motor at full speed according to EN13215 conditions.
As compressor and fan motor are placed in a packaged unit, effect of noise reduction due to enclosure and insulation was considered for evaluation of sound power
Subject to change without prior information, Please check Coolselector 2 / Product store for updated information.
Distance (in Meters)
Sound Pressure (dB(A))
Acoustic/Sound Spectrum Data (50Hz)
Model
Sound Power Spectrum, 1/1 Octave
Calculated Sound Pressure (Free Field) (dBA)
Sound Power Spectrum
63
67
69
71
70
70
79
59
43
81
0
10
20
30
40
50
60
70
80
90
100
63 125 250 500 1000 2000 4000 8000 16k LWA
SOUND POWER SPECTRUM (DBA)
1/1 OCTAVE FREQUENCY (HZ)
Acoustic/Sound Spectrum (50Hz)
Weighted dBA
Loading...