Danfoss MCD 600 Fact sheet

Fact Sheet

VLT® Soft Starter MCD 600 delivers superior performance for fixed-speed applications

Typecode selector

Flexible installation:

Wide variety of Ethernet and serial-based communication option cards

Application-dedicated smart cards

Increased savings

Integrated bypass ensures both high efficiency and harmonic-free operation at full speed, reducing energy consumed and cooling requirements.

Easier to operate with new capabilities:

Pump-clean function

PowerThrough operation

Calendar or run time-based scheduling

Enhanced protection delivers increased uptime.

Simulation mode with no power to the motor

MCD600Chassis Digital Soft Starter with Built in Bypass & Motor Overload Protection

 

 

Maximum FLC Ratings

230VAC

460VAC

600VAC

 

Part

Standard*

 

Heavy**

Standard*

 

Heavy**

Stan-

 

Heavy**

Standard*

Heavy**

 

 

 

 

 

 

 

dard*

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

Motor

Motor

 

Motor

Motor

Motor

 

 

 

 

 

 

 

 

 

 

 

 

HP (nom)

 

HP (nom)

HP (nom)

 

HP (nom)

HP (nom)

HP (nom)

 

MCD6-0020B

17

 

14

5

 

3

10

 

10

15

10

 

MCD6-0034B

28

22

10

7.5

20

15

20

20

 

MCD6-0042B

35

 

28

10

 

10

25

 

20

30

25

 

MCD6-0063B

52

40

15

10

40

30

40

30

 

MCD6-0069B

59

 

46

20

 

15

40

 

30

50

40

 

MCD6-0086B

77

52

25

15

60

40

60

50

 

MCD6-0108B

81

 

65

30

 

20

60

 

50

75

60

 

MCD6-0129B

99

77

30

25

75

60

100

75

 

MCD6-0144B

124

 

96

40

 

30

100

 

75

 

75

 

 

 

 

125

 

MCD6-0171B

131

104

50

40

100

75

125

100

 

MCD6-0194B

156

 

124

60

 

40

125

 

100

 

125

 

 

 

 

150

 

MCD6-0244B

195

156

75

60

150

125

200

150

 

MCD6-0287B

240

 

180

75

 

60

200

 

150

 

150

 

 

 

 

200

 

MCD6-0323B

261

203

100

75

200

150

250

200

 

MCD6-0410B

377

 

302

150

 

100

300

 

250

350

300

 

MCD6-0527B

414

321

150

125

350

250

450

300

 

MCD6-0579B

477

 

361

200

 

150

400

 

300

500

350

 

MCD6-0654B

515

414

200

150

450

350

500

450

 

MCD6-0736B

590

 

480

200

 

300

500

 

400

600

500

 

MCD6-0950B

796

619

300

250

600

500

800

600

 

MCD6-1154B

984

 

768

400

 

300

800

 

600

1000

800

 

MCD6-1250B

1130

903

450

350

900

700

1100

900

 

MCD6-0160C

146

 

118

50

 

40

100

 

75

150

100

 

MCD6-0215C

176

144

60

50

125

100

150

150

 

MCD6-0275C

233

 

185

75

 

60

150

 

150

200

150

 

MCD6-0343C

306

246

100

75

250

200

300

250

 

MCD6-0448C

354

 

336

125

 

125

250

 

250

350

350

 

MCD6-0590C

480

382

200

150

400

300

500

400

 

MCD6-0667C

576

 

431

200

 

150

450

 

350

600

450

 

MCD6-0839C

722

590

300

200

600

500

700

600

 

MCD6-0979C

864

 

722

350

 

300

700

 

600

900

700

 

MCD6-1134C

966

784

400

300

800

600

1000

800

 

 

 

 

 

 

 

 

 

 

 

 

 

*Standard Duty350% current, 30 second ramp, 4 starts per hour **Heavy Duty450% current, 30 second ramp, 4 starts per hour For light duty applications please consult factory

www.danfossdrives.com

Danfoss MCD 600 Fact sheet

Mains voltage range

3 x 200-525 VAC (T5)

3 x 380-690 VAC (T7)

Current range and enclosure

IP20: 20-129 A (nominal)

IP00: 144-1250 A (nominal)

Additional features

Advanced start, stop and protection features

Auto start/stop clock

Compact size

DC injection braking

4-line graphical display

Multiple programming setup menus

Available options

Fieldbus communication modules:

EtherNet/IP

PROFINET

Modbus TCP

PROFIBUS

DeviceNet

Modbus RTU

Remote LCP Option

Application card

Smart Pump

PC software:

WinStart

VLT® Motion Control Tool MCT 10

Enclosed options available - consult factory

VLT® Control Panel LCP 601

Remote mountable option kit

IP65 enclosure class

3 m cable included

Features:

Graphical, multi-line display

Real-time graphing

Full parameter list, Quick Menu and application setup

Adjustable multiple monitoring views

Feature

 

 

 

 

Benefit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quick set-up menu

 

 

 

 

Adjusts key parameters to suit the application, reducing

 

 

 

 

 

 

start-up time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Log menu – up to 348 individual events recorded

 

Eases analysis of the application

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump clean functionality and deragging

 

Helps dislodge debris from impeller without extra

 

 

 

components

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Integrated USB port

 

 

 

 

– Reduced startup and upgrade time

 

 

(Parameter copy, data logging, firmware updates)

 

Easy access to operational data

 

 

AAC Adaptive Acceleration Control

 

 

 

– Automatically adapts to the chosen start/stop profile

 

Reversing contactor control

 

 

 

 

Allows for soft starting in any direction

 

 

 

 

 

 

Does not require any external contactors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– Save space and wiring

 

 

 

 

Internal bypass contactors

 

 

 

 

– Reduced heat dissipation when running

 

 

 

 

 

 

 

 

Eliminates costly external components

 

 

PowerThrough operation

 

 

 

 

Utilizes 2-phase control when one phase is damaged

 

 

 

 

 

 

(shorted SCR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Onscreen, dynamic QR-codes

 

 

 

 

Provides information about the MCD 600,

 

 

 

 

 

 

including­

serial number and failure ­information

 

 

 

 

 

 

 

 

 

Control voltage (terminals A4, A5, A6)

 

 

 

 

 

 

 

 

 

 

 

CV1 (A8, A9)

 

 

 

 

24 VAC/VDC (± 20%), 2.8 A

 

 

 

 

CV2 (A8, A9)

 

 

 

 

110-120 VAC (+ 10% / -15%), 600 mA

 

 

CV2 (A8, A9)

 

 

 

 

220-240 VAC (+ 10% / -15%), 600 mA

 

 

Mains frequency

 

 

 

 

50/60 Hz (± 5%)

 

 

 

 

Inputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input rating

 

 

 

 

Active 24 VDC, 8 mA (approximately)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor thermistor (TER-05, TER-06)

 

 

 

Trip > 3.6 kΩ, reset > 1.6 kΩ

 

 

Outputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay outputs

 

 

 

 

10 A @ 250 VAC resistive

 

 

 

 

 

 

 

 

5 A @ 250 VAC AC15 pf 0.3

 

 

 

 

 

 

 

 

 

 

Main Contactor (13, 14)

 

 

 

 

Normally open

 

 

 

 

Relay output A (21, 22, 23)

 

 

 

 

Changeover

 

 

 

 

 

 

Relay output B (33, 34)

 

 

 

 

Normally open

 

 

 

 

Analog Output (AO-07, AO-08)

 

 

 

 

0-20 mA or 4-20 mA (selectable)

 

 

Maximum load

 

 

 

 

600 Ω (12 VDC @ 20 mA) (accuracy ± 5%)

 

 

Environmental

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protection MCD6-0020B ~ MCD6-0129B

 

IP20

 

 

 

 

 

 

 

 

Protection MCD6-0144B ~ MCD6-1250B

 

IP00

 

 

 

 

 

 

 

 

Operating temperature

 

 

 

 

-10° C to 60° C, above 40° C with derating

 

 

Storage temperature

 

 

 

 

-25° C to + 60° C

 

 

 

 

Operating altitude

 

 

 

 

0-1000 m, above 1000 m with derating

 

 

Humidity

 

 

 

 

5% to 95% relative humidity

 

 

Pollution degree

 

 

 

 

Pollution Degree 3

 

 

 

 

Vibration

 

 

 

 

IEC 60068-2-6

 

 

 

 

Dimensions - with Internal Bypass

 

 

 

 

 

 

 

 

 

Current Rating [A]

Weight [lbs]

Height [in]

Width [in]

Depth [in]

Frame Size

 

20 - 129B

 

10.7

 

13.2

 

 

 

6

 

9.1

 

S1

 

 

10.9

 

 

 

 

 

 

 

 

 

 

12.1

 

 

 

 

 

 

 

 

 

 

 

 

144 - 244B

 

28

 

19.5

 

 

 

8.5

 

9.6

 

S2

 

287 - 410B

 

34.2

 

20.6

 

 

 

8.5

 

9.6

 

 

527 - 579B

 

41.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

654 - 736B

 

112.4

 

 

 

 

 

 

 

 

 

 

 

 

950B

 

136.7

 

24.3

 

 

 

17.6

12.3

 

S3

 

1154B

 

138.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1250B

 

143.3

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions - without Internal Bypass

 

 

 

 

 

 

 

 

 

Current Rating [A]

Weight [lbs]

Height [in]

Width [in]

Depth [in]

Frame Size

 

160 - 215C

 

26.9

 

19.5

 

 

 

8.5

 

9.6

 

S2

 

275 - 343C

 

 

28.2

 

20.6

 

 

 

 

 

 

448C

 

35.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

590 - 667C

 

103.6

 

 

 

 

 

 

 

 

 

 

 

 

839C

 

127.9

 

24.3

 

 

 

17.6

12.3

 

S3

 

979C

 

130.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1134C

 

134.5

 

 

 

 

 

 

 

 

 

 

 

 