Option now also applicable for VLT® AQUA Drive FC 202.
VLT® Programmable I/O MCB 115
Installation Guide
Introduction
1 Introduction
1.1 P
urpose of this Installation Guide
This manual provides information for safe installation of a VLT® Programmable I/O MCB 115 option used in the VLT® FC drive series.
The installation guide is intended for use by qualied personnel only. Personnel must be familiar with the VLT® FC drive series.
Read and follow the instructions before installation, and ensure that instructions for safe installation are observed. Always keep
these instructions available with the drive.
1.2 Trademarks
VLT® is a registered trademark for Danfoss A/S.
1.3 Document Version
This manual is regularly reviewed and updated. All suggestions for improvement are welcome. See document version and changes
applied in
T
he original language of this manual is English.
1.4 Additional Resources
M
ore information resources are available to understand advanced drive functions and programming.
•
•
•
Technical documentation for other product options is available at
Version and Changes Applied.
The VLT® FC Series Operating Guides provide information required to install and commission the drive for given applications.
The VLT® FC Series Programming Guides provide greater detail on working with parameters.
VLT® FC Series Design Guides provide detailed capabilities and functionality to design motor control systems for various applications.
www.danfoss.com.
1.5 P
roduct Overview
1.5.1 Intended Use
The VLT® Programmable I/O MCB 115 is intended to:
•
Extend the I/O selection available on the control card, for example, for multi-zone control with 3 pressure transmitters.
•
Turn the AC drive into a decentralized I/O block supporting building automation systems with inputs and outputs.
•
Support the extended PI controllers with I/Os for setpoint inputs, transmitter/sensor inputs, and outputs for actuators.
•
Provide a digital output used for:
-
Driving a relay.
-
Input to commonly used PLC I/O boards.
-
Input to another AC drive in a sequentially controlled application.
The VLT® Programmable I/O MCB 115 is intended for use only with:
•
VLT® HVAC Drive FC 102
•
VLT® Refrigeration Drive FC 103
•
VLT® AQUA Drive FC 202
•
VLT® AutomationDrive FC 301
•
VLT® AutomationDrive FC 302
N O T I C E
The VLT® P
rogrammable I/O MCB 115 is only functional if it is built into the drive. The option cannot be used as a standalone.
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
W A R N I N G
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
C A U T I O N
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
N O T I C E
Indicates information considered important, but not hazard-related (for example messages relating to property damage).
Safety
ualied Personnel
2.2 Q
The products must only be assembled, installed, programmed, commissioned, maintained, and decommissioned by persons with
proven skills. Persons with proven skills:
Are qualied electrical engineers, or persons who have received training from qualied electrical engineers and are suitably ex-
•
perienced to operate devices, systems, plant, and machinery in accordance with the general standards and guidelines for safety
technology.
Are familiar with the basic regulations concerning health and safety/accident prevention.
•
Have read and understood the safety guidelines given in this manual and also the instructions given in the operating guide of
•
the drive.
Have good knowledge of the generic and specialist standards applicable to the specic application.
•
2.3 Safety Precautions
W A R N I N G
UNINTENDED START
W
hen the drive is connected to the AC mains, DC supply, or load sharing, the motor may start at any time, causing risk of death,
serious injury, and equipment or property damage. The motor may start by activation of an external switch, a eldbus command,
an input reference signal from the LCP or LOP, via remote operation using MCT 10 Set-up software, or after a cleared fault condi-
tion.
Press [O] on the LCP before programming parameters.
-
Disconnect the drive from the mains whenever personal safety considerations make it necessary to avoid unintended motor
-
start.
Check that the drive, motor, and any driven equipment are in operational readiness.
-
W A R N I N G
LACK OF SAFETY AWARENESS
T
his document gives important information on how to prevent injury and damage to the equipment or the system. Ignoring
them can lead to death, serious injury, or severe damage to the equipment.
Make sure to fully understand the dangers and safety measures incurred in the application.
Danfoss can accept no responsibility for possible errors in catalogs, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This
also applies t
trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss A/S
Ulsnaes 1
DK-6300 Graasten
vlt-drives.danfoss.com
o products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All